Investigation of necessary conditions for imaging cell analysis using EIT

被引:0
|
作者
Gibas, Christian [1 ]
Veckollari, Birgyl [2 ,3 ]
Schulte, Gregor [2 ,3 ]
Mueller, Mareike [2 ,3 ]
Brueck, Rainer [1 ]
Schoenherr, Holger [2 ,3 ]
机构
[1] Univ Siegen, Med Informat & Microsyst Design, Holderlinstr 3, D-57076 Siegen, Germany
[2] Univ Siegen, Phys Chem 1, Adolf Reichwein Str 2, D-57076 Siegen, Germany
[3] Univ Siegen, Res Ctr Micro & Nanochem & Engn C, Adolf Reichwein Str 2, D-57076 Siegen, Germany
来源
MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING | 2019年 / 10953卷
关键词
Cellular Imaging; EIT imaging; EIT chip; Differential Image Reconstruction; TISSUE;
D O I
10.1117/12.2512404
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrical Impedance Tomography (EIT) is a method used to record the impedance distribution within a target. The best-known application of EIT is lung diagnostics using imaging algorithms. However, apart from this, there are individual research projects dealing with imaging analysis at the cellular level. For example, cell analysis using EIT can help to distinguish diseased cells from healthy cells. To achieve this goal, an existing EIT system was combined with a new EIT chip in a first step. This chip allows analysis in very small dimensions. Various parameters such as the diameter of the measuring environment, the necessary conductive solutions or the measuring methods used were varied and evaluated. In a next step, various image reconstructions were carried out using data acquired with C. elegans.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Sensitivity analysis of thorax imaging using two-dimensional Electrical Impedance Tomography (EIT)
    Andiani, L.
    Rubiyanto, A.
    Endarko
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [2] THE NECESSARY CONDITIONS FOR LOCAL VISUAL ANALYSIS
    MORRONE, MC
    BURR, DC
    ROSS, J
    PERCEPTION, 1985, 14 (01) : A7 - A7
  • [3] Conditions necessary for the activity of chloroplasts outside the cell
    Boichenko, EA
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES DE L URSS, 1943, 38 : 181 - 184
  • [4] Images reproducibility of an Electrical Impedance Tomography (EIT) prototype.: Analysis of the EIT sensibility in rats in pathological in vivo conditions
    Gaona, A
    Aguillón, P
    Mendoza, J
    López, L
    González, E
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2296 - 2298
  • [5] Simulation Study of Scaffold 3D Cell Culture Imaging Using A Miniature Planar EIT Sensor
    Yang, Yunjie
    Wu, Hancong
    Jia, Jiabin
    2017 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2017, : 589 - 594
  • [6] Statistical analysis for brain EIT images using SPM
    Zhang, Y
    Passmore, PJ
    Yerworth, RJ
    Bayford, RH
    THIRD INTERNATIONAL CONFERENCE ON MEDICAL INFORMATION VISUALISATION - BIOMEDICAL VISUALISATION (MEDIVIS 2005), PROCEEDINGS, 2005, : 60 - 67
  • [7] Investigation of necessary conditions for creation and preservation of helical structures,in plasma
    Stránsky, M
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2002, 52 : 235 - 239
  • [8] Investigation of the Necessary Conditions for Effective Leukocytes' Labeling with the Colloidal Complex
    Zavadovskaya, V.
    Kilina, O.
    Zorkaltsev, M.
    Udodov, V.
    Zamyshevskaya, M.
    Kurazhov, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S326 - S326
  • [9] Using live cell imaging in the investigation of cell signalling in a model of peripheral tolerance
    Tunbridge, H. M.
    Wraith, D. C.
    Wuelfing, C.
    IMMUNOLOGY, 2014, 143 : 139 - 139
  • [10] SOLPS analysis of the necessary conditions for detachment cliff
    Du, Hailong
    Zheng, Guoyao
    Guo, Houyang
    Jaervinen, Aaro E.
    Duan, Xuru
    Bonnin, Xavier
    Eldon, David
    Wang, Dezhen
    NUCLEAR FUSION, 2020, 60 (04)