Conventional ventilation versus high-frequency oscillation: Hemodynamic effects in newborn babies

被引:30
|
作者
Simma, B [1 ]
Fritz, M [1 ]
Fink, C [1 ]
Hammerer, I [1 ]
机构
[1] Childrens Hosp, Intens Care Unit, Innsbruck, Austria
关键词
cardiac performance; high-frequency oscillation; newborns;
D O I
10.1097/00003246-200001000-00038
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: We conducted a prospective study to assess the hemodynamic effects of conventional mechanical ventilation (CMV) compared with high-frequency oscillation (HFO) in newborn babies with respiratory distress syndrome. Methods: A total of 18 consecutive term and preterm infants were examined by two-dimensional M-mode and pulsed Doppler echocardiography. Results: Five patients had to be excluded, three of them because of increasing cardiovascular support after initiation of HFO. The remaining 13 infants (seven males, six females) had a median gestational age of 33 wks (range, 25-40) and a birth weight of 2350 g (range, 790-3600). Patients entered the study at 21 hrs (range, 5-69) of life, receiving total maintenance fluid of 90 mL/kg/day (range, 60-120). Five babies (38%) needed continuous inotropic support. HFO was used as a rescue therapy in infants who failed with CMV. In all 13 patients, HFO significantly impaired cardiac performance compared with CMV by decreasing aortic velocity-time integral: median, 10.2 cm (range, 6.0-14.6) vs. 8.3 cm (range, 5.3-12.4; p < .002); stroke volume: median, 3.8 mt (range, 1.6-6.8) vs. 3.2 mt (range, 1.3-5.9; p < .002); and cardiac index: 281 mL/min/kg of body weight (range, 177-579) vs. 200 mL/min/kg of body weight (range, 156-591; p < .002). Fractional shortening was also significantly reduced: median, 0.31% (range, 0.24-0.44) vs. 0.29% (range, 0.20-0.34; p < .01), because of a significantly smaller left ventricular diastolic diameter during HFO: median, 1.4 cm (range, 1.0-1.9) vs. 1.4 cm (range, 0.9-1.8; p < .05), with a median difference of -0.07 cm (range, -0.4-0.2). HFO also causes a significant decrease in heart rate-corrected left ventricular election time: median, 0.25 sec (range, 0.23-0.28) vs. 0.23 sec (range, 0.21-0.26; p < .02) and heart rate-corrected velocity of circumferential fiber shortening (Vcfc): median, 1.3 circ/sec (range, 1.0-1.6) vs. 1.2 circ/sec (range, 0.9-1.4; p < .05). Left ventricular end-systolic wall stress (LVESWS; g/cm(2)) remained stable. The correlation between Vcfc and LVESWS did not show any significance (CMV, r(2) = .2; HFO, r(2) = .09). The regression line between Vcfc and LVESWS showed a higher y-intercept and steeper slope during CMV than during HFO. Heart rate, mean arterial pressure, and left ventricular systolic diameter remained unchanged. Conclusions: In newborn babies, HFO significantly decreased left ventricular cardiac output caused by reduced left ventricular filling and HFO decreased contractility at higher mean airway pressures than with CMV.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [31] BRONCHOSCOPIC FINDINGS IN INFANTS TREATED WITH HIGH-FREQUENCY JET VENTILATION VERSUS CONVENTIONAL VENTILATION
    KERCSMAR, CM
    MARTIN, RJ
    CHATBURN, RL
    CARLO, WA
    [J]. PEDIATRICS, 1988, 82 (06) : 884 - 887
  • [32] High-frequency oscillatory ventilation versus conventional mechanical ventilation in congenital diaphragmatic hernia
    Cacciari, A
    Ruggeri, G
    Mordenti, M
    Ceccarelli, PL
    Baccarini, E
    Pigna, A
    Gentili, A
    [J]. EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2001, 11 (01) : 3 - 7
  • [33] HIGH-FREQUENCY VENTILATION VERSUS CONVENTIONAL MECHANICAL VENTILATION IN PEDIATRIC RESPIRATORY-FAILURE
    HERSHENSON, MB
    WYLAM, ME
    [J]. CRITICAL CARE MEDICINE, 1995, 23 (08) : 1443 - 1444
  • [34] High-frequency oscillatory ventilation versus conventional ventilation in the treatment of air leak syndromes
    Karagianni, P
    Drossou-Agakidou, V
    Nikolaides, N
    Sarafidis, K
    Diamanti, E
    Kremenopoulos, G
    [J]. PROCEEDINGS OF THE XIX EUROPEAN CONGRESS OF PERINATAL MEDICINE, 2004, : 519 - 523
  • [35] High-frequency oscillatory ventilation versus conventional ventilation for acute respiratory distress syndrome
    Sud, Sachin
    Sud, Maneesh
    Friedrich, Jan O.
    Wunsch, Hannah
    Meade, Maureen O.
    Ferguson, Niall D.
    Adhikari, Neill K. J.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (04):
  • [36] HIGH-FREQUENCY JET VENTILATION VERSUS CONVENTIONAL VENTILATION AFTER SURFACTANT DISPLACEMENT IN DOGS
    KUMAR, BS
    BENEY, K
    JASTREMSKI, M
    NIEMAN, G
    BREDENBERG, C
    [J]. CRITICAL CARE MEDICINE, 1984, 12 (09) : 738 - 741
  • [37] EFFECTS OF CONVENTIONAL AND HIGH-FREQUENCY JET VENTILATION ON LUNG PARENCHYMA
    KESZLER, M
    KLEIN, R
    MCCLELLAN, L
    NELSON, D
    PLATT, M
    [J]. CRITICAL CARE MEDICINE, 1982, 10 (08) : 514 - 516
  • [38] EFFECTS OF HIGH-FREQUENCY AND CONVENTIONAL VENTILATION ON THE PREMATURE LAMB LUNG
    SOLIMAO, A
    JOBE, A
    IKEGAMI, M
    JACOBS, H
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (05) : 1571 - 1577
  • [39] SUPERIMPOSED HIGH-FREQUENCY VENTILATION WITH CONVENTIONAL MECHANICAL VENTILATION
    BARZILAY, E
    KESSLER, D
    RAZ, R
    [J]. CHEST, 1989, 95 (03) : 681 - 682
  • [40] High-frequency oscillation and partial liquid ventilation
    Mammel, MC
    [J]. CRITICAL CARE MEDICINE, 2001, 29 (06) : 1293 - 1293