Analytical study of point fixed glass facade systems under monotonic in-plane loading

被引:3
|
作者
Sivanerupan, S. [1 ]
Wilson, J. L. [1 ]
Gad, E. F. [1 ]
Lam, N. T. K. [2 ]
机构
[1] Swinburne Univ Technol, Fac Sci Engn & Technol, Hawthorn, Vic 3122, Australia
[2] Univ Melbourne, Melbourne Sch Engn, Parkville, Vic 3052, Australia
基金
澳大利亚研究理事会;
关键词
ANSYS; facade systems; finite element modelling; in-plane drift capacity; point fixed glass; DAMAGE ASSESSMENT; BUILDINGS;
D O I
10.1177/1369433216630192
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The point fixed glass facade system is popular and considered a more elegant facade option compared to the framed glass facade system mainly for storefront, walkways and lobby areas in buildings. Point fixed glass facade system is fixed to the support structure using special bolt fittings and structural spider arms. Generally, the racking performance of these systems is not considered at the design stage in low to moderate seismic region and the system may be vulnerable if there is insufficient in-plane drift capacity compared with the demand imposed during earthquakes and wind actions. A unique full-scale in-plane racking laboratory test on a typical point fixed glass facade system was conducted and a maximum drift of 2.1% was measured before catastrophic failure. Non-linear finite element models were then developed and benchmarked against experimental results. The experimental results and finite element analyses indicated that a significant amount of the drift capacity was attributed to the rigid body translation in the facade system connections at the built-in oversize holes provided for construction tolerances. In this article, the laboratory test setup and the experimental results are summarised, and the finite element modelling methodology and non-linear analysis approach undertaken using ANSYS for the experimental test are discussed along with number of parametric studies.
引用
收藏
页码:611 / 626
页数:16
相关论文
共 50 条
  • [21] An Application of the Fixed Point Theory to the Study of Monotonic Solutions for Systems of Differential Equations
    Branga, Adrian Nicolae
    Olaru, Ion Marian
    MATHEMATICS, 2020, 8 (07)
  • [22] ANALYTICAL SOLUTIONS FOR VIBRATION NEAR THE BUCKLED CONFIGURATION OF FGM BEAMS UNDER AN IN-PLANE THERMAL LOADING
    Ma, L. S.
    ADVANCES IN HETEROGENEOUS MATERIAL MECHANICS 2011, 2011, : 1112 - 1115
  • [23] Combined experimental and analytical study using cruciform specimen for testing advanced aeropropulsion materials under in-plane biaxial loading
    Abdul-Aziz, All
    Krause, David
    NONDESTRUCTIVE EVALUATION AND HEALTH MONITORING OF AEROSPACE MATERIALS, COMPOSITES, AND CIVIL INFRASTRUCTURE V, 2006, 6176
  • [24] Analytical model for textile reinforced mortar under monotonic loading
    Filippou, Christiana A.
    Chrysostomou, Christis Z.
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 258
  • [25] Plate girders behaviour under in-plane loading: A review
    Tetougueni, Cyrille Denis
    Maiorana, Emanuele
    Zampieri, Paolo
    Pellegrino, Carlo
    ENGINEERING FAILURE ANALYSIS, 2019, 95 : 332 - 358
  • [26] Numerical simulation of an adobe wall under in-plane loading
    Nicola, Tarque
    Guido, Camata
    Humberto, Varum
    Enrico, Spacone
    Marcial, Blondet
    EARTHQUAKES AND STRUCTURES, 2014, 6 (06) : 627 - 646
  • [27] Failure criteria for masonry panels under in-plane loading
    Andreaus, U
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (01): : 37 - 46
  • [28] Tests of masonry panels under in-plane lateral loading
    Aliawdin, P
    Simbirkin, V
    Epstein, V
    8TH INTERNATIONAL CONFERENCE ON MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2004, : 330 - 333
  • [29] Failure of spot welds under in-plane static loading
    Wung, P
    Walsh, T
    Ourchane, A
    Stewart, W
    Jie, M
    EXPERIMENTAL MECHANICS, 2001, 41 (01) : 100 - 106
  • [30] Dynamic crushing of hexagonal honeycombs under in-plane loading
    Zhang Xin-chun