Use of a hands-free, noninvasive Doppler ultrasound device to measure carotid blood flow during resuscitation from cardiac arrest

被引:0
|
作者
Little, Charles M.
Larabee, Todd M.
Cohen-Solal, Eric
Raju, Balasundar
Nakagawa, Michael
Erkamp, Ramon
Ayati, Shervin
机构
[1] Univ Colorado, Hlth Sci Ctr, Denver, CO 80202 USA
[2] Philips Med Syst, Andover, MA USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1197 / 1197
页数:1
相关论文
共 50 条
  • [21] A NONINVASIVE DIAGNOSTIC METHOD FOR AORTIC REGURGITATION BY DETECTING CAROTID BLOOD-FLOW WITH BIDIRECTIONAL DOPPLER ULTRASOUND
    WANG, WQ
    ZHU, HS
    YO, GF
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (05): : 597 - 600
  • [22] Carotid Doppler blood flow measurement during cardiopulmonary resuscitation is feasible: A first in man study
    Adedipe, Adeyinka A.
    Fly, Deborah L.
    Schwitz, Scott D.
    Jorgenson, Dawn B.
    Duric, Haris
    Sayre, Michael R.
    Nichol, Graham
    RESUSCITATION, 2015, 96 : 121 - 125
  • [23] Validation of noninvasive measurements of cerebral blood flow and oxygenation in a pediatric swine model of cardiac arrest and cardiopulmonary resuscitation
    Ko, T.
    Mavroudis, C.
    Boorady, T.
    Mensah-Brown, K.
    Morgan, R.
    Lautz, A.
    Karlsson, M.
    Bratinov, G.
    Berg, R.
    Yodh, A.
    Sutton, R.
    Licht, D.
    Kilbaugh, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 287 - 288
  • [24] NONINVASIVE MEASUREMENT OF VELOCITY PROFILES AND BLOOD-FLOW IN COMMON CAROTID-ARTERY BY PULSED DOPPLER ULTRASOUND
    KELLER, HM
    MEIER, WE
    ANLIKER, M
    KUMPE, DA
    STROKE, 1976, 7 (04) : 370 - 377
  • [25] CEREBRAL BLOOD-FLOW IN HUMANS FOLLOWING RESUSCITATION FROM CARDIAC-ARREST
    COHAN, SL
    MUN, SK
    PETITE, J
    CORREIA, J
    DASILVA, AT
    WALDHORN, RE
    STROKE, 1989, 20 (06) : 761 - 765
  • [26] An impedance threshold device did not improve carotid blood flow in a porcine model of prolonged cardiac arrest
    Benedict Kjaergaard
    Hans O. Holdgaard
    Sigridur O. Magnusdottir
    Søren Lundbye-Christensen
    Erika F. Christensen
    Journal of Translational Medicine, 18
  • [27] An impedance threshold device did not improve carotid blood flow in a porcine model of prolonged cardiac arrest
    Kjaergaard, Benedict
    Holdgaard, Hans O.
    Magnusdottir, Sigridur O.
    Lundbye-Christensen, Soren
    Christensen, Erika F.
    JOURNAL OF TRANSLATIONAL MEDICINE, 2020, 18 (01)
  • [28] Impairment of Carotid Artery Blood Flow by Supraglottic Airway Use in a Swine Model of Cardiac Arrest
    Segal, Nicolas
    Yannopoulos, Demetris
    Mahoney, Brian D.
    Frascone, Ralph J.
    Cowles, Colin G.
    McKnite, Scott H.
    Chase, David G.
    CIRCULATION, 2011, 124 (21)
  • [29] Impairment of carotid artery blood flow by supraglottic airway use in a swine model of cardiac arrest
    Segal, Nicolas
    Yannopoulos, Demetris
    Mahoney, Brian D.
    Frascone, Ralph J.
    Matsuura, Timothy
    Cowles, Colin G.
    McKnite, Scott H.
    Chase, David G.
    RESUSCITATION, 2012, 83 (08) : 1025 - 1030
  • [30] Cerebral blood flow is decoupled from blood pressure and linked to EEG bursting after resuscitation from cardiac arrest
    Crouzet, Christian
    Wilson, Robert H.
    Bazrafkan, Afsheen
    Farahabadi, Maryam H.
    Lee, Donald
    Alcocer, Juan
    Tromberg, Bruce J.
    Choi, Bernard
    Akbari, Yama
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (11): : 4660 - 4673