Purpose: To develop and evaluate a new staging system that can specifically be used for the classification of visual field defects with Humphrey Matrix Frequency Doubling 30-2 threshold test. Materials and Methods: The new frequency doubling technology staging system version (FDT SS 2) was created on the basis of a total of 200 tests obtained from 34 normal subjects, 67 patients with ocular hypertension (OHT), and 99 with primary open-angle chronic glaucoma (POAG). This system was used to classify defect severity in another group of 54 patients having POAG tested with the Humphrey Matrix 30-2 threshold test. A modified 5-stage classification method of Aulhorn and Karmeyer was taken as the gold standard. The reliability of FDT SS2 in categorizing according to type of defect (generalized, mixed, and localized) was also compared with a clinical classification on the basis of the analysis of probability maps. A control sample of 48 normal subjects was also analyzed. Results: With regards to the glaucomatous patients, 38 of 54 (70.4%) resulted with the same severity classification. All FDT SS2 grades (100%) were within 1 level of the clinical grade. The ability of FDT SS2 to correctly define the type of defect was also quite good (Spearman test: 0.719, P < 0.001). In the control group, the FDT SS2 classified 45 of 48 cases as stage 0, giving a specificity of 93.7%. Conclusions: The new FDT SS2 is able to both stage the severity of functional damage studied with the Humphrey Matrix 30-2 threshold test, and to correctly distinguish between generalized, localized, and mixed defects. Key Words: frequency-doubling technology (FDT), primary open-angle glaucoma (POAG), visual field defect staging, functional damage classification.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 50 条
  • [21] Normal aging effects for frequency doubling technology perimetry
    Adams, CW
    Bullimore, MA
    Wall, M
    Fingeret, M
    Johnson, CA
    OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) : 582 - 587
  • [22] Frequency doubling technology perimetry in rhegmatogenous retinal detachment
    Chou, LC
    Sheu, SJ
    Chen, YY
    Chen, JF
    Wu, TT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U138 - U138
  • [23] Frequency Doubling Technology screening test in glaucoma detection
    Byles, DB
    Sherafat, H
    Diamond, JP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S86 - S86
  • [24] Mechanisms isolated by frequency-doubling technology perimetry
    Anderson, AJ
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (02) : 398 - 401
  • [25] Fibered laser system for atom interferometers based on telecom technology at 1560 nm and frequency doubling
    Carraz, Olivier
    Lienhart, Fabien
    Zahzam, Nassim
    Bidel, Yannick
    Bresson, Alexandre
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 382 - 383
  • [26] Usefulness of frequency doubling technology perimetry 24-2 in glaucoma with parafoveal scotoma
    Jung, Kyoung In
    Kim, Eun Kyoung
    Park, Chan Kee
    MEDICINE, 2017, 96 (24)
  • [27] Frequency doubling technology perimetry using a 24-2 stimulus presentation pattern
    Johnson, CA
    Cioffi, GA
    Van Buskirk, EM
    OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) : 571 - 581
  • [28] Comparison of frequency doubling technology and Swedish interactive technology algorithm perimetry.
    Moya, FJ
    Shafranov, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S285 - S285
  • [29] Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension
    Mauro Cellini
    Pier Giorgio Toschi
    Ernesto Strobbe
    Nicole Balducci
    Emilio C Campos
    BMC Ophthalmology, 12
  • [30] Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension
    Cellini, Mauro
    Toschi, Pier Giorgio
    Strobbe, Ernesto
    Balducci, Nicole
    Campos, Emilio C.
    BMC OPHTHALMOLOGY, 2012, 12