A comparative analysis of pregnancy outcomes of patients with uterine fibroids after high intensity focused ultrasound ablation and laparoscopic myomectomy: a retrospective study

被引:19
|
作者
Jiang, Zhaoying [1 ]
Li, Qing [1 ]
Li, Waixing [1 ]
Zhu, Xiaogang [1 ]
Jiang, Jianfa [1 ]
Chen, Lixing [1 ]
He, Sili [1 ]
Xue, Min [1 ]
Ye, Mingzhu [1 ]
Li, Xilei [2 ,3 ]
机构
[1] Cent South Univ, Xiangya Hosp 3, Dept Gynaecol, 138 Tongzipo Rd, Changsha 410013, Hunan, Peoples R China
[2] Cent South Univ, Xiangya Hosp, Dept Anesthesiol, 87 Xiangya Rd, Changsha 410008, Hunan, Peoples R China
[3] Cent South Univ, Xiangya Hosp, Natl Clin Res Ctr Geriatr Disorders, Changsha, Peoples R China
关键词
Uterine fibroids; pregnancy; high intensity focused ultrasound ablation; laparoscopic myomectomy; influencing factor; REPRODUCTIVE OUTCOMES; ADENOMYOSIS; EFFICACY;
D O I
10.1080/02656736.2021.1874547
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to retrospectively compare and analyze pregnancy outcomes of patients with uterine fibroids after high intensity focused ultrasound (HIFU) ablation and laparoscopic myomectomy (LM). Materials and methods: The study group consisted of 346 patients with uterine fibroids who wished to conceive, in which 152 patients received HIFU ablation treatment (HIFU group) and 194 patients received LM treatment (LM group). The parents' baseline characters were recorded and the pregnancy outcomes were evaluated in a median follow-up time of 42 months (range: 16 similar to 81) after the treatment, and the differences of the two groups were compared. Results: Patients with uterine fibroids in HIFU group had a significant shorter pregnancy interval than that in LM group (10 months VS. 13 months, p < .05). No significant differences were observed in pregnancy rate, miscarriage rate, live birth rate, natural pregnancy rate, cesarean section rate, and perinatal complications rate between the HIFU group and the LM group (p > .05). When stratified by age, infertility history, fibroid types, fibroid numbers, and fibroid sizes, there was no statistically significant difference in pregnancy rate between the HIFU group and the LM group (p > .05). Conclusions: Based on the results from this study, both HIFU and LM can be safely used to treat patients who wish to conceive. The pregnancy outcomes of post-HIFU are similar to that of post-LM.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [41] PILOT STUDY OF MR-GUIDED HIGH INTENSITY FOCUSED ULTRASOUND (MRGHIFU) ABLATION OF UTERINE FIBROIDS.
    Pulanic, T. Klepac
    Venkatesan, A.
    Segars, J.
    Partanen, A.
    Merino, M.
    Stratton, P.
    [J]. FERTILITY AND STERILITY, 2010, 94 (04) : S222 - S222
  • [42] Effect of high-intensity focused ultrasound on sexual function in the treatment of uterine fibroids: comparison to conventional myomectomy
    Wang, Xiaoyan
    Qin, Juan
    Wang, Lifang
    Chen, Jinyun
    Chen, Wenzhi
    Tang, Liangdan
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2013, 288 (04) : 851 - 858
  • [43] Effect of high-intensity focused ultrasound on sexual function in the treatment of uterine fibroids: comparison to conventional myomectomy
    Xiaoyan Wang
    Juan Qin
    Lifang Wang
    Jinyun Chen
    Wenzhi Chen
    Liangdan Tang
    [J]. Archives of Gynecology and Obstetrics, 2013, 288 : 851 - 858
  • [44] Pregnancy outcomes after ultrasound-guided high-intensity focused ultrasound (USgHIFU) for conservative treatment of uterine fibroids: experience of a single institution
    Rodriguez, J.
    Isern, J.
    Pons, N.
    Carmona, A.
    Vallejo, E.
    Cassado, J.
    De Marcos, J. A.
    Paraira, M.
    Gimenez, N.
    Pessarrodona, A.
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (02) : 9 - 17
  • [45] Vaginal delivery outcomes of pregnancies following ultrasound-guided high-intensity focused ultrasound ablation treatment for uterine fibroids
    Liu, Xin
    Xue, Lijuan
    Wang, Yang
    Wang, Wei
    Tang, Jie
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 510 - 517
  • [46] A retrospective study of ultrasound-guided high intensity focussed ultrasound ablation for multiple uterine fibroids in South Africa
    He, Min
    Jacobson, Hayley
    Zhang, Cai
    Setzen, Raymond
    Zhang, Lian
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (08) : 1304 - 1310
  • [47] Preliminary study on ultrasound-guided high-intensity focused ultrasound ablation for treatment of broad ligament uterine fibroids
    Wang, Yiran
    Xu, Yonghua
    Wong, Felix
    Wang, Yi
    Cheng, Yu
    Yang, Lixia
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (02) : 18 - 23
  • [48] RETRACTED: The Comparison of Life Quality between Ultrasound-Guided High-Intensity Focused Ultrasound and Laparoscopic Myomectomy for the Treatment of Uterine Fibroids (Retracted Article)
    Yuan, Bilin
    Qin, Xinyi
    Xi, Jie
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [49] Ultrasound-Guided High-Intensity Focused Ultrasound vs Laparoscopic Myomectomy for Symptomatic Uterine Myomas
    Wang, Fulan
    Tang, Liangdan
    Wang, Li
    Wang, Xiaoyan
    Chen, Jinyun
    Liu, Xiaohua
    Gong, Yao
    [J]. JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2014, 21 (02) : 279 - 284
  • [50] A Prediction of NPVR ≥ 80% of Ultrasound-Guided High-Intensity Focused Ultrasound Ablation for Uterine Fibroids
    Yang, Mei-Jie
    Yu, Ren-Qiang
    Chen, Wen-Zhi
    Chen, Jin-Yun
    Wang, Zhi-Biao
    [J]. FRONTIERS IN SURGERY, 2021, 8