Investigation on transient thermal hydraulics of reduced scale passive residual heat removal heat exchanger in tank

被引:16
|
作者
Tao, Jiaqi [1 ]
Gu, Hanyang [1 ]
Xiong, Zhenqin [1 ]
Jiang, Xing [2 ]
Xie, Yongcheng [2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Nucl Sci & Engn, Dongchuan Rd 800, Shanghai, Peoples R China
[2] Shanghai Nucl Engn Res & Design Inst, Shanghai, Peoples R China
关键词
Porous media approach; PRHR HX; Numerical simulation; Experimental validation; Passive heat removal; TURBULENT FREE-CONVECTION; CORRELATING EQUATIONS; LAMINAR; BUNDLES; SYSTEM;
D O I
10.1016/j.anucene.2019.03.011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In advanced nuclear power plant AP1000, the passive residual heat removal heat exchanger (PRHR HX) is a key part of the passive safety system. It can transfer decay heat from the reactor core to the water in the in-containment refueling water storage tank (IRWST) during the accidents. The secure operation of the C-shaped PRHR HX has a great impact on the reactor safety. In the present work, the heat transfer performance of a reduced scale PRHR HX was investigated by experiments and numerical simulations. A system including a 6 x 7 C-shaped tube bundle and a rectangular tank was studied. A three-dimensional numerical model using porous media method was developed to explore the transient single phase thermal hydraulic characteristics of the PRHR HX. The distributed resistances caused by the C-shaped tube bundle were calculated by empirical correlations. Both the heat transfer coefficients from the hot fluid in the tube to the inside surface of tube and that from the outer tube surface to the water in the IRWST were calculated by empirical correlations published in literatures. Tests were performed on the 6 x 7 C-shaped tube bundle installed in the middle of the tank. The outer wall temperature and bulk water temperature in the tank were measured by thermocouples. The numerical methods were validated by the experimental results. The calculated results of the local temperature distribution and heat transfer rate were both well consistent with the experimental values. The deviation of the heat transfer rate was smaller than 5%. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:402 / 410
页数:9
相关论文
共 50 条
  • [1] CFD investigation on thermal hydraulics of the passive residual heat removal heat exchanger (PRHR HX)
    Ge, Jian
    Tian, Wenxi
    Qiu, Suizheng
    Su, G. H.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2018, 327 : 139 - 149
  • [2] Investigation on Heat Transfer Performance of Passive Residual Heat Removal Heat Exchanger in Half Water Level Tank
    Liu, Jing
    Ye, Cheng
    Xiong, Zhenqin
    Tao, Jiaqi
    Gu, Hanyang
    Jiang, Xing
    Xie, Yongcheng
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2021, 55 (11): : 1991 - 1997
  • [3] NUMERICAL INVESTIGATION ON HEAT REMOVAL CAPACITY OF PASSIVE RESIDUAL HEAT REMOVAL HEAT EXCHANGER
    Zhang, Wenwen
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    [J]. PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 4, 2014,
  • [4] THERMAL HYDRAULICS NUMERICAL SIMULATION AND OPTIMIZED DESIGN OF PASSIVE RESIDUAL HEAT REMOVAL HEAT EXCHANGER IN AP1000
    Xia, Huining
    Lu, Daogang
    Du, Zheng
    Zhang, Yuhao
    Fu, Xiaoliang
    Ma, Zhongying
    Yang, Yanhua
    Liang, Min
    [J]. PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [5] Parametric analysis of heat transfer rate of passive residual heat removal heat exchanger submerged in water tank
    Tao, Jiaqi
    Gu, Hanyang
    Xiong, Zhenqin
    Jiang, Xing
    Xie, Yongcheng
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 98 : 317 - 327
  • [6] Heat Transfer Analysis of Passive Residual Heat Removal Heat Exchanger under Natural Convection Condition in Tank
    Men, Qiming
    Wang, Xuesheng
    Zhou, Xiang
    Meng, Xiangyu
    [J]. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2014, 2014
  • [7] Numerical simulation of passive residual heat removal heat exchanger
    Xue, Ruo-Jun
    Deng, Cheng-Cheng
    Peng, Min-Jun
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (04): : 429 - 435
  • [8] Transient analysis and optimization of passive residual heat removal heat exchanger in advanced nuclear power plant
    Liu, Yan-Bin
    Meng, Xiang-Yu
    Wang, Xue-Sheng
    Men, Qi-Ming
    Yuan, Yu-Yang
    Cao, Jia-Ming
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (08)
  • [9] Transient analysis and optimization of passive residual heat removal heat exchanger in advanced nuclear power plant
    Yan-Bin Liu
    Xiang-Yu Meng
    Xue-Sheng Wang
    Qi-Ming Men
    Yu-Yang Yuan
    Jia-Ming Cao
    [J]. Nuclear Science and Techniques, 2022, 33 (08) : 149 - 164
  • [10] Transient analysis and optimization of passive residual heat removal heat exchanger in advanced nuclear power plant
    Yan-Bin Liu
    Xiang-Yu Meng
    Xue-Sheng Wang
    Qi-Ming Men
    Yu-Yang Yuan
    Jia-Ming Cao
    [J]. Nuclear Science and Techniques, 2022, 33