Investigation on Heat Transfer Performance of Passive Residual Heat Removal Heat Exchanger in Half Water Level Tank

被引:0
|
作者
Liu J. [1 ]
Ye C. [2 ]
Xiong Z. [1 ]
Tao J. [1 ]
Gu H. [1 ]
Jiang X. [2 ]
Xie Y. [2 ]
机构
[1] School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai
[2] Shanghai Nuclear Engineering Research & Design Institute Co., Ltd., Shanghai
关键词
Half water level condition; Heat transfer performance; Passive residual heat removal heat exchanger; Thermal stratification;
D O I
10.7538/yzk.2020.youxian.0862
中图分类号
学科分类号
摘要
Passive residual heat removal heat exchanger (PRHR HX) is one of the key equipments of a passive core residual heat removal system of advanced nuclear reactors, which is placed in a in-containment refueling water storage tank (IRWST). The water level of the tank decreases due to the water evaporation under the accident condition or the water leakage by accident, and then the heat transfer area of PRHR HX and water outside the tubes and the external flow field of the tubes change, resulting in the decrease of the passive residual heat removal ability of the core. The experimental device and numerical model of half water level PRHR HX were established to analysis the heat transfer performance of PRHR HX in half water level condition. And the heat transfer rate, temperature distribution and flow field characteristics were obtained both in transient and steady states. The experimental results show that the heat transfer rate is reduced only 12%-22% from that in a full tank to that in half water level tank, the passive residual heat removal system still has higher heat transfer capacity. During the transient heating process, the heat transfer mode outside the tube starts from the pure single phase convective flow heat transfer, gradually appears local subcooled boiling and local saturated boiling. Finally, the heat transfer mode rapidly changes from local to the whole tube length saturated boiling. Moreover, a significant thermal stratification phenomenon still exists in the process of gradually heating up in the water tank. The local flow circulation at different regions with different heights is found in numerical simulation results. © 2021, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:1991 / 1997
页数:6
相关论文
共 16 条
  • [1] (2010)
  • [2] STEVENS O L., Characterization of the advanced plant experiment (APEX) passive residual heat removal system heat exchanger, (1996)
  • [3] (2017)
  • [4] ZHANG Y, LU D, WANG Z, Et al., Experimental investigation on pool-boiling of C-shape heat exchanger bundle used in PRHR HX, Applied Thermal Engineering, 114, 11, pp. 186-195, (2017)
  • [5] ZHANG Yuhao, LU Daogang, WANG Zhongyi, Et al., Experimental investigation on heat transfer model for secondary side of scaled C-shape bundle used in PRHR HX of AP1000, Atomic Energy Science and Technology, 50, 10, pp. 1763-1770, (2016)
  • [6] XUE Ruojun, DENG Chengcheng, PENG Minjun, Numerical simulation of passive residual heat removal heat exchanger, Atomic Energy Science and Technology, 44, 4, pp. 429-435, (2010)
  • [7] XUE Ruojun, WANG Mingyuan, LI Zhaojun, Et al., Numerical simulation of AP1000 passive residual heat removal heat exchanger, Journal of Harbin Institute of Technology, 44, 11, pp. 133-138, (2012)
  • [8] (2012)
  • [9] TAO J, GU H, XIONG Z, Et al., Investigation on transient thermal hydraulics of reduced scale passive residual heat removal heat exchanger in tank, Annals of Nuclear Energy, 130, 8, pp. 402-410, (2019)
  • [10] TAO Jiaqi, GU Hanyang, XIONG Zhenqin, Et al., Parametric analysis of heat transfer rate of passive residual heat removal heat exchanger submerged in water tank, Experimental Thermal & Fluidence, 98, 5, pp. 317-327, (2018)