Research of Safety Protection for Live Working on 1000kV AC Ultra High Voltage Transmission Line

被引:0
|
作者
Liu Kai [1 ]
Wang Linong [1 ]
Hu Yi [2 ]
Shao Guiwei [2 ]
Liu Ting [2 ]
Hu Jianxun [2 ]
Xiao Bin [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan, Peoples R China
[2] State Grid Elect Power Res Inst, Wuhan, Peoples R China
关键词
ultra high voltage; 1000kV AC transmission line; live working; safety protection; screening clothes;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Safety protection research for live working on 1000kV AC transmission line was made. The screening clothes for live working was developed and tested. Both material of clothes and the characteristics were researched with standards. According to the actual situation of operation, the electric field intensity on different parts of body and the current passing through human were measured in equal-potential process. The research results show the clothes can meet the safety protection requirements for live work on 1000kV transmission line. The working man should wear full set screening clothes with face screening mask and the potential rod should be used during equal-potential process.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Research on shielding protection of live working on ±500k V DC transmission line
    Hu, Yi
    Wang, Linong
    Xiao, Yong
    [J]. Gaodianya Jishu/High Voltage Engineering, 2002, 28 (09):
  • [42] Analysis and Evaluation of the DC Magnetic Bias for 1000kV Ultra-High Voltage Transformer Caused by Changsha Rail Transit
    State Grid Hunan Electric Power Company Limted Research Institute, Changsha, Hunan
    410007, China
    [J]. IOP Conf. Ser. Earth Environ. Sci., 2020, 5
  • [43] Impact of transmission line parameters on harmonic transmission coefficients in 1000 kV AC power transmission system
    Liu, Shu-Ming
    Xu, Yong-Hai
    Zhu, Yong-Qiang
    Xiao, Xiang-Ning
    [J]. Dianwang Jishu/Power System Technology, 2010, 34 (01): : 11 - 14
  • [44] Analysis and Evaluation of the DC Magnetic Bias for 1000kV Ultra-High Voltage Transformer Caused by Changsha Rail Transit
    Yuan, Pei
    Liu, Yun
    Li, Xin
    Xu, Puming
    Yan, Ying
    Hu, Jinhao
    [J]. 2020 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, PTS 1-5, 2020, 546
  • [45] Research on key technologies in ±1100 kV ultra-high voltage DC transmission
    Liu, Zehong
    Zhang, Fuxuan
    Yu, Jun
    Gao, Keli
    Ma, Weimin
    [J]. HIGH VOLTAGE, 2018, 3 (04): : 279 - 288
  • [46] Study on the Construction and Application of Digital Twins on High Voltage Transmission Line Live Working Scenes
    Guo, Jianlong
    Wu, Qinghua
    Guo, Ke
    Xiong, Shan
    Feng, Weixia
    Xue, Jiang
    [J]. IEEE ACCESS, 2021, 9 : 111587 - 111594
  • [47] RESEARCH ON CONDUCTOR GALLOPING OF LARGE SPAN LINE IN ULTRA-HIGH VOLTAGE TRANSMISSION LINE
    Liu, Cao-lan
    Liu, Bin
    Zhan, Xue-ping
    Qi, Yi
    [J]. MATERIAL ENGINEERING AND MECHANICAL ENGINEERING (MEME2015), 2016, : 341 - 350
  • [48] Live Working on Electrode line of ±800kV DC Transmission Project
    Tang Pan
    Fang Yuqun
    Liu Kai
    Liu Ting
    [J]. 2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 691 - 694
  • [49] Helicopter Live-Line Work on 1000-kV UHV Transmission Lines
    Liao, Caibo
    Ruan, Jiangjun
    Liu, Chao
    Du, Zhiye
    Wen, Wu
    Zhou, Taotao
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (03) : 982 - 989
  • [50] Design of 1000-kV AC Single-Circuit Overhead Transmission Line
    Li Yongwei1
    2.State Grid Corporation of China
    3.Central Southern China Electric Power Design Institute
    4.North China Electric Power Design Institute Co.Ltd. Wang Xingguo
    [J]. Electricity, 2010, 21 (03) : 38 - 42