Dual functional rhodium oxide nanocorals enabled sensor for both non-enzymatic glucose and solid-state pH sensing

被引:28
|
作者
Dong, Qiuchen [1 ]
Huang, Yikun [1 ]
Song, Donghui [1 ]
Wu, Huixiang [2 ]
Cao, Fei [3 ]
Lei, Yu [1 ,4 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, 191 Auditorium Rd, Storrs, CT 06269 USA
[2] Chongqing Univ, Coll Bioengn, Minist Educ, Key Lab Biorheol Sci & Technol, Chongqing 400044, Peoples R China
[3] China Pharmaceut Univ, Sch Sci, Key Lab Biomed Funct Mat, Nanjing 211198, Jiangsu, Peoples R China
[4] Univ Connecticut, Dept Chem & Biomol Engn, 191 Auditorium Rd, Storrs, CT 06269 USA
来源
关键词
Rhodium oxide; Dual sensor; Nanocorals; Non-enzymatic glucose detection; Solid-state pH sensing; CARBON NANOTUBES; NANOWIRES; NANOFIBERS; BIOSENSORS;
D O I
10.1016/j.bios.2018.04.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Both pH-sensitive and glucose-responsive rhodium oxide nanocorals (Rh2O3 NCs) were synthesized through electrospinning followed by high-temperature calcination. The as-prepared Rh2O3 NCs were systematically characterized using various advanced techniques including scanning electron microscopy, X-ray powder diffraction and Raman spectroscopy, and then employed as a dual functional nanomaterial to fabricate a dual sensor for both non-enzymatic glucose sensing and solid-state pH monitoring. The sensing performance of the Rh2O3 NCs based dual sensor toward pH and glucose was evaluated using open circuit potential, cyclic voltammetry and amperometric techniques, respectively. The results show that the as-prepared Rh2O3 NCs not only maintain accurate and reversible pH sensitivity of Rh2O3, but also demonstrate a good electrocatalytic activity toward glucose oxidation in alkaline medium with a sensitivity of 11.46 mu A mM(-1) cm(-2), a limit of detection of 3.1 mu M (S/N = 3), and a reasonable selectivity against various interferents in non-enzymatic glucose detection. Its accuracy in determining glucose in human serum samples was further demonstrated. These features indicate that the as-prepared Rh2O3 NCs hold great promise as a dual-functional sensing material in the development of a high-performance sensor forManjakkal both solid-state pH and non-enzymatic glucose sensing.
引用
收藏
页码:136 / 142
页数:7
相关论文
共 50 条
  • [31] Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide
    Wu, Geng-huang
    Song, Xin-hong
    Wu, Yan-fan
    Chen, Xiao-mei
    Luo, Feng
    Chen, Xi
    TALANTA, 2013, 105 : 379 - 385
  • [32] MWCNT-ruthenium oxide composite paste electrode as non-enzymatic glucose sensor
    Tehrani, Ramin M. A.
    Ab Ghani, Sulaiman
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 278 - 283
  • [33] Development of sensitive non-enzymatic glucose sensor using complex nanostructures of cobalt oxide
    Soomro, Razium Ali
    Nafady, Aynam
    Ibupoto, Zafar Hussain
    Sirajuddin
    Sherazi, Syed Tufail Hussain
    Willander, Magnus
    Abro, Muhammad Ishaq
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2015, 34 : 373 - 381
  • [34] Preparation and performance of non-enzymatic glucose sensor electrode based on nanometer cuprous oxide
    Yu, Xiaojiao
    Zhang, Jie
    Tang, Xiyan
    Wei, Yuchen
    Kou, Song
    Niu, Jinfen
    Yao, Binghua
    NANOMATERIALS AND NANOTECHNOLOGY, 2018, 8
  • [35] A Novel Non-Enzymatic Glucose Sensor Based on Nickel (II) Oxide Electrospun Nanofibers
    Wang, Wei
    Li, Zhenyu
    Zheng, Wei
    Dong, Bo
    Li, Shangyu
    Wang, Ce
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2010, 10 (11) : 7537 - 7540
  • [36] Well-dispersed palladium nanoparticles on graphene oxide as a non-enzymatic glucose sensor
    Wang, Qiyu
    Cui, Xiaoqiang
    Chen, Jianli
    Zheng, Xianliang
    Liu, Chang
    Xue, Tianyu
    Wang, Haitao
    Jin, Zhao
    Qiao, Liang
    Zheng, Weitao
    RSC ADVANCES, 2012, 2 (15): : 6245 - 6249
  • [37] Copper/reduced graphene oxide film modified electrode for non-enzymatic glucose sensing application
    Phetsang, Sopit
    Kidkhunthod, Pinit
    Chanlek, Narong
    Jakmunee, Jaroon
    Mungkornasawakul, Pitchaya
    Ounnunkad, Kontad
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [38] Vertically Aligned Nanosheets of an Electrodeposited Lanthanum Oxide Electrode for Non-Enzymatic Glucose Sensing Application
    Jadhav, S. B.
    Patil, U. M.
    Bulakhe, R. N.
    In, Insik
    Lokhande, C. D.
    Pawaskar, P. N.
    JOURNAL OF ELECTRONIC MATERIALS, 2021, 50 (02) : 675 - 685
  • [39] Copper/reduced graphene oxide film modified electrode for non-enzymatic glucose sensing application
    Sopit Phetsang
    Pinit Kidkhunthod
    Narong Chanlek
    Jaroon Jakmunee
    Pitchaya Mungkornasawakul
    Kontad Ounnunkad
    Scientific Reports, 11
  • [40] Non-enzymatic amperometric sensing of glucose by employing sucrose templated microspheres of copper oxide (CuO)
    Saraf, Mohit
    Natarajan, Kaushik
    Mobin, Shaikh M.
    DALTON TRANSACTIONS, 2016, 45 (13) : 5833 - 5840