Automated rectilinear self-gated cardiac cine imaging

被引:98
|
作者
Crowe, ME
Larson, AC
Zhang, Q
Carr, J
White, RD
Li, DB
Simonetti, OP
机构
[1] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[3] Cleveland Clin Fdn, Sect Cardiovasc Imaging, Div Radiol, Cleveland, OH 44195 USA
[4] Siemens Med Solut Inc, Chicago, IL USA
关键词
CMR; self-gating; triggering; cine;
D O I
10.1002/mrm.20212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ECG-based gating in cardiac MR imaging requires additional patient preparation time, is susceptible to RF and magnetic interference, and is ineffective in a significant percentage of patients. "Wireless" or "self-gating" techniques have been described using either interleaved central k-space lines or projection reconstruction to obtain MR signals synchronous with the cardiac cycle. However, the interleaved, central line method results in a doubling of the acquisition time, while radial streak artifacts are encountered with the projection reconstruction method. In this work, a new self-gating technique is presented to overcome these limitations. A retrospectively gated TrueFISP cine sequence was modified to acquire a short second echo after the readout and phase gradients are rewound. The information obtained from this second echo was used to derive a gating signal. This technique was compared to ECG-based gating in 10 healthy volunteers and shown to have no significant difference in image quality. The results indicate that this method could serve as an alternative gating strategy without the need for external physiological signal detection. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:782 / 788
页数:7
相关论文
共 50 条
  • [41] Nonlinear profile order for 3D hybrid radial acquisition applied to self-gated free-breathing cardiac cine MRI
    Yanchun Zhu
    Shuo Li
    Jie Yang
    Rongmao Li
    Zhicheng Zhang
    Shaode Yu
    Yaoqin Xie
    [J]. Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [42] Nonlinear profile order for three-dimensional hybrid radial acquisition applied to self-gated free-breathing cardiac cine MRI
    朱艳春
    Pascal Spincemaille
    刘静
    李硕
    Thanh D Nguyen
    Martin R Prince
    谢耀钦
    王乙
    [J]. Chinese Physics B, 2017, 26 (01) : 572 - 577
  • [43] Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory
    Usman, M.
    Ruijsink, B.
    Nazir, M. S.
    Cruz, G.
    Prieto, C.
    [J]. MAGNETIC RESONANCE IMAGING, 2017, 38 : 129 - 137
  • [44] Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function
    Jing Liu
    Li Feng
    Hsin-Wei Shen
    Chengcheng Zhu
    Yan Wang
    Kanae Mukai
    Gabriel C. Brooks
    Karen Ordovas
    David Saloner
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 337 - 346
  • [45] Accelerated self-gated UTE of murine heart
    Wolter L de Graaf
    Abdallah Motaal
    Nils Noorman
    Luc Florack
    Klaas Nicolay
    Gustav J Strijkers
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [46] Performance of Simultaneous Cardiac-Respiratory Self-gated Three-dimensional MR Imaging of the Heart: Initial Experience
    Manka, Robert
    Buehrer, Martin
    Boesiger, Peter
    Fleck, Eckart
    Kozerke, Sebastian
    [J]. RADIOLOGY, 2010, 255 (03) : 909 - 916
  • [47] Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function
    Liu, Jing
    Feng, Li
    Shen, Hsin-Wei
    Zhu, Chengcheng
    Wang, Yan
    Mukai, Kanae
    Brooks, Gabriel C.
    Ordovas, Karen
    Saloner, David
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (04) : 337 - 346
  • [48] Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields
    Verena Hoerr
    Nina Nagelmann
    Arno Nauerth
    Michael T Kuhlmann
    Jörg Stypmann
    Cornelius Faber
    [J]. Journal of Cardiovascular Magnetic Resonance, 15
  • [49] Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields
    Hoerr, Verena
    Nagelmann, Nina
    Nauerth, Arno
    Kuhlmann, Michael T.
    Stypmann, Joerg
    Faber, Cornelius
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [50] Self-gated fetal cardiac MRI with tiny golden angle iGRASP: A feasibility study
    Haris, Kostas
    Hedstrom, Erik
    Bidhult, Sebastian
    Testud, Frederik
    Maglaveras, Nicos
    Heiberg, Einar
    Hansson, Stefan R.
    Arheden, Hakan
    Aletras, Anthony H.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (01) : 207 - 217