Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients

被引:102
|
作者
Bur, A [1 ]
Hirschl, MM [1 ]
Herkner, H [1 ]
Oschatz, E [1 ]
Kofler, J [1 ]
Woisetschläger, C [1 ]
Laggner, AN [1 ]
机构
[1] Univ Clin Vienna, Dept Emergency Med, Vienna Gen Hosp, A-1090 Vienna, Austria
关键词
oscillometric blood pressure measurement; cuff size; critically ill patients; emergency medicine; intensive care medicine; noninvasive; monitoring; upper arm circumference; mean arterial blood pressure; catecholamine treatment; mechanical ventilation;
D O I
10.1097/00003246-200002000-00014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Design: Prospective data collection. Setting: Emergency department in a 2,000-bed inner city hospital, Patients: Thirty-eight patients categorized into three groups according to their upper-arm circumference (group 1: 18-25 cm; group 11: 25.1-33 cm; and group ill: 33.1-47.5 cm) were enrolled in the study protocol, Interventions: In each patient, all three cuff sizes (Hewlett-Packard Cuff 40401 B, C, and D) were used to perform an oscillometric blood pressure measurement at least within 3 mins until ten to 20 measurements for each cuff size were achieved. Invasive mean arterial blood pressure measurement was done by cannulation of the contralateral radial artery with direct transduction of the systemic arterial pressure waveform, The corresponding invasive blood pressure value was obtained at the end of each oscillometric measurement. Measurement and Main Results: Overall, 1,494 pairs of simultaneous oscillometric and invasive blood pressure measurements were collected in 38 patients (group I, n = 5; group II, n = 23; and group III, n = 10) over a total time of 72.3 hrs, Mean arterial blood pressure ranged from 35 to 165 mm Hg, The overall discrepancy between oscillometric and invasive blood pressure measurement was -6.7 +/- 9.7 mm Hg (p < ,0001), if the recommended cuff size according to the upper-arm circumference was used (539 measurements), Of all the blood pressure measurements, 26.4% (n = 395) had a discrepancy of greater than or equal to 10 mm Hg and 34.2% (n = 512) exhibited a discrepancy of greater than or equal to 20 mm Hg. No differences between invasive and noninvasive blood pressure measurements were noted in patients either with or without inotropic support (-6,6 + 7.2 vs, -8.6 + 6.8 mm Hg; not significant). Conclusion: The oscillometric blood pressure measurement significantly underestimates arterial blood pressure and exhibits a high number of measurements out of the clinically acceptable range, The relation between cuff size and upper-arm circumference contributes substantially to the inaccuracy of the oscillometric blood pressure measurement, Therefore, oscillometric blood pressure measurement does not achieve adequate accuracy in critically ill patients.
引用
收藏
页码:371 / 376
页数:6
相关论文
共 50 条
  • [1] THE IMPACT OF RELATION BETWEEN CUFF SIZE AND ARM CIRCUMFERENCE ON BLOOD PRESSURE MEASUREMENT
    Xie Dongyang
    Cai Jiumei
    [J]. HEART, 2012, 98 : E254 - E254
  • [2] Home blood pressure measurement with oscillometric upper-arm devices
    Braam, RL
    Thien, T
    [J]. NETHERLANDS JOURNAL OF MEDICINE, 2003, 61 (10): : 307 - 312
  • [3] Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients
    Bur, A
    Herkner, H
    Vlcek, M
    Woisetschläger, C
    Derhaschnig, U
    Delle Karth, G
    Laggner, AN
    Hirschl, MM
    [J]. CRITICAL CARE MEDICINE, 2003, 31 (03) : 793 - 799
  • [4] BLOOD PRESSURE MEASUREMENT: ARM CIRCUMFERENCE AND CUFF SIZE AVAILABILITY
    Veiga, Eugenia Velludo
    Moura Arcuri, Edna Aparecida
    Cloutier, Lyne
    Ferreira Santos, Jair Licio
    [J]. REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2009, 17 (04): : 455 - 461
  • [5] ACCURACY OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT IN CRITICALLY ILL NEONATES
    GEVERS, M
    VANGENDERINGEN, HR
    LAFEBER, HN
    HACK, WW
    [J]. PEDIATRIC RESEARCH, 1994, 36 (01) : A15 - A15
  • [6] THE EFFECT OF ARM CIRCUMFERENCE AND BLOOD PRESSURE CUFF SIZE ON BLOOD PRESSURE MEASUREMENT IN PREGNANCY
    Mangos, G. J.
    Ong, S.
    Kho, L.
    Brown, M.
    [J]. NEPHROLOGY, 2008, 13 : A129 - A129
  • [7] Accuracy of wrist cuff oscillometric blood pressure measurement in obese patients
    Wertli, M.
    Ruckstuhl, N.
    Vetter, W.
    Suter, P. M.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 : S25 - S25
  • [8] Comparison of a wrist cuff oscillometric blood pressure measurement device with an upper arm-cuff oscillometric device in obese subjects
    de Senarclens, Olivier
    Feihl, Francois
    Giusti, Vittorio
    Engelberger, Rolf P.
    Rodieux, Frederique
    Gomez, Patrick
    Liaudet, Lucas
    Waeber, Bernard
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 : 173 - 173
  • [9] Blood Pressure Measurement in Pregnancy: The Effect of Arm Circumference and Sphygmomanometer Cuff Size
    Brown, Mark
    Kho, Lily
    Ong, S.
    Mangos, George
    [J]. HYPERTENSION IN PREGNANCY, 2008, 27 (04) : 595 - 595
  • [10] Blood pressure measurement in pregnancy: the effect of arm circumference and sphygmomanometer cuff size
    Kho, Chye L.
    Brown, Mark A.
    Ong, Sharon L. H.
    Mangos, George J.
    [J]. OBSTETRIC MEDICINE, 2009, 2 (03) : 116 - 120