MRI to X-ray Fluoroscopy Overlay for Guidance of Cardiac Resynchronization Therapy Procedures

被引:0
|
作者
Ma, YingLiang [2 ]
Duckett, Simon [2 ]
Chinchapatnam, Phani [2 ]
Gao, Gang [2 ]
Shetty, Anoop [2 ]
Rinaldi, C. Aldo [1 ]
Schaeffter, Tobias [2 ]
Rhode, Kawal S. [2 ]
机构
[1] St Thomas Hosp, NHS Fdn, London SE1 7EH, England
[2] Kings Coll London, London, England
来源
关键词
HEART; SEGMENTATION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac resynchronization therapy (CRT) can be an effective procedure for patients with heart failure but 30% of patients do not respond. This may be partially caused by the sub-optimal placement of the left ventricular lead. We demonstrate how pre-procedural cardiac MR images can be used to assist CRT by integration of anatomical and functional information with live X-ray images. We evaluated our approach in 7 patients. Each patient underwent pre-CRT MRI scan using MultiHance contrast. This included whole heart imaging sequence; 3D tagged and cine imaging for function; and late enhancement imaging for scar. The MRI data were processed to yield a detailed anatomical model. Whole heart segmentation was achieved automatically using the Philips EP Planner and the coronary venous anatomy was manually segmented by a clinical expert. Functional information was derived using the Tomtec 4D LV-Analysis. The left ventricle was segmented into the standard 16 segment AHA model and the functional information could be added to this. If scar was present, this was segmented by an expert and added to the model. The implant was carried out using a Philips Allura X-ray system and the detailed cardiac model was registered to the X-ray fluoroscopy using multiple views of a catheter looped in the right atrium. There was complete freedom of movement of the X-ray system and respiratory motion compensation was achieved by tracking the diaphragm. The software framework was a specially modified version of the Philips EP Navigator. We validated the registration using balloon occlusion coronary veno-grams. The mean 2D target registration error for 7 patients was 1.3 +/- 0.68 mm. Furthermore, left lead deployment was successful in all patients.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 50 条
  • [1] Respiratory motion compensated overlay of surface models from cardiac MR on interventional X-ray fluoroscopy for guidance of cardiac resynchronization therapy procedures
    Manzke, R.
    Bornstedt, A.
    Lutz, A.
    Schenderlein, M.
    Hombach, V.
    Binner, L.
    Rasche, V.
    [J]. MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [2] Real-Time Cardiac MR Anatomy and Dyssynchrony Overlay for Guidance of Cardiac Resynchronization Therapy Procedures: Clinical Results Update
    Ma, YingLiang
    Shetty, Anoop
    Duckett, Simon
    Rinaldi, C. Aldo
    Schaeffter, Tobias
    Razavi, Reza
    Carr-White, Gerry
    Rhode, Kawal S.
    [J]. FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2011, 6666 : 313 - +
  • [3] Precise X-ray and video overlay for augmented reality fluoroscopy
    Xin Chen
    Lejing Wang
    Pascal Fallavollita
    Nassir Navab
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 29 - 38
  • [4] Precise X-ray and video overlay for augmented reality fluoroscopy
    Chen, Xin
    Wang, Lejing
    Fallavollita, Pascal
    Navab, Nassir
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (01) : 29 - 38
  • [5] X-ray and magnetic resonance imaging fusion for cardiac resynchronization therapy
    Choi, Jinwoo
    Radau, Perry
    Xu, Robert
    Wright, Graham A.
    [J]. MEDICAL IMAGE ANALYSIS, 2016, 31 : 98 - 107
  • [6] ACUTE RADIATION-INJURY CAUSED BY FAULTY X-RAY FLUOROSCOPY DURING CARDIAC PROCEDURES
    IYER, PS
    [J]. HEALTH PHYSICS, 1976, 31 (04): : 385 - 386
  • [7] Edge-enhancement densenet for X-ray fluoroscopy image denoising in cardiac electrophysiology procedures
    Luo, Yimin
    Ma, Yingliang
    O' Brien, Hugh
    Jiang, Kui
    Kohli, Vikram
    Maidelin, Sesilia
    Saeed, Mahrukh
    Deng, Emily
    Pushparajah, Kuberan
    Rhode, Kawal S.
    [J]. MEDICAL PHYSICS, 2022, 49 (02) : 1262 - 1275
  • [8] Image and Physiological Data Fusion for Guidance and Modelling of Cardiac Resynchronization Therapy Procedures
    Ma, YingLiang
    Duckett, Simon
    Chinchapatnam, Phani
    Shetty, Anoop
    Rinaldi, C. Aldo
    Schaeffter, Tobias
    Rhode, Kawal S.
    [J]. STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART, 2010, 6364 : 105 - +
  • [9] A Device Enhancing and Denoising Algorithm for X-ray Cardiac Fluoroscopy
    Bismuth, Vincent
    Vaillant, Regis
    [J]. 19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 1802 - 1805
  • [10] REAL-TIME IMAGE GUIDANCE OF BRONCHOSCOPIC PROCEDURES USING X-RAY FLUOROSCOPY AND EBUS FOR PERIPHERAL PULMONARY LESIONS
    Xu, Ye
    Zeng, Mingying
    Xu, Di
    Xu, Sheng
    Yung, Rex C.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S426 - S427