摘要
Geothermal is considered to be one of the most promising renewable sources for district heating. Ground source heat pump systems coupled with the coaxial deep borehole heat exchanger have been widely applied because of their high efficiency. However, in order to reduce the total energy consumption of the system, there are few studies on the optimization of the water flow rates in the coaxial deep borehole heat exchanger by time to meet the load change during the heating season. In this paper, an optimization method for the two flow rates which are set at two time periods respectively every day in the coaxial deep borehole heat exchanger during the operation of the ground source heat pump system is proposed. The application of the method is to determine the applicable flow rates when the temperature of the next day is predicted. Space heating of a building (located in Tianjin, China) is taken as a scenario, comparisons were carried out on system operation before and after optimization, which shows that the method has a good effect on the energy-saving operation of the system. After optimization, the total power consumption of the system is reduced, the total performance coefficient of the equipment as well as the temperature difference between the inlet and outlet of the underground heat exchanger is increased, and the trend of flow rates changes with time is the same as the indoor and outdoor temperature difference.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Simulation-based analysis of a ground source heat pump system using super-long flexible heat pipes coupled borehole heat exchanger during heating season
    Wang, Xiaoyuan
    Wang, Yinfeng
    Wang, Zhi
    Liu, Yuxuan
    Zhu, Yuezhao
    Chen, Haijun
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 164 : 132 - 143
  • [32] Research on ground heat exchanger of Ground Source Heat Pump technique
    LIU Dong-sheng
    [J]. Global Geology, 2004, (02) : 196 - 199
  • [33] Efficiency and economic analysis of utilizing latent heat from groundwater freezing in the context of borehole heat exchanger coupled ground source heat pump systems
    Zheng, Tianyuan
    Shao, Haibing
    Schelenz, Sophie
    Hein, Philipp
    Vienken, Thomas
    Pang, Zhonghe
    Kolditz, Olaf
    Nagel, Thomas
    [J]. APPLIED THERMAL ENGINEERING, 2016, 105 : 314 - 326
  • [34] Transient heat transfer in a coaxial borehole heat exchanger
    Beier, Richard A.
    Acuna, Jose
    Mogensen, Paine
    Palm, Bjorn
    [J]. GEOTHERMICS, 2014, 51 : 470 - 482
  • [35] Coupled heating of ground-coupled heat pump system with heat compensation unit: Performance improvement and borehole reduction
    You, Tian
    Li, Xianting
    Wu, Wei
    Shi, Wenxing
    Wang, Baolong
    Soga, Kenichi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 57 - 67
  • [36] THE GROUND SOURCE HEAT PUMP: A SYSTEM ANALYSIS WITH A PARTICULAR FOCUS ON THE U-PIPE BOREHOLE HEAT EXCHANGER
    Madani, Hatef
    Acuna, Jose
    Claesson, Joachim
    Lundqvist, Per
    Palm, Bjorn
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 395 - 402
  • [37] The performance of the backfills of the borehole heat exchanger of the ground source heat pump system in cooling dominated region of China
    Ma, W.
    Hao, J.
    Zhang, C.
    Guo, F.
    Wen, H.
    [J]. SUSTAINABLE BUILDINGS AND STRUCTURES: BUILDING A SUSTAINABLE TOMORROW, 2020, : 243 - 248
  • [38] In-situ test and numerical investigation on the long-term performance of deep borehole heat exchanger coupled heat pump heating system
    Liu, Bin
    Wang, Jiangfeng
    Li, Hongyan
    Liu, Jian
    Wang, Pengtao
    Cai, Wanlong
    Sun, Xianpeng
    Chen, Chaofan
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [39] Combined simulation of a deep ground source heat exchanger and an office building
    Huchtemann, K.
    Mueller, D.
    [J]. BUILDING AND ENVIRONMENT, 2014, 73 : 97 - 105
  • [40] Numerical study of geothermal district heating from a ground heat exchanger coupled with a heat pump system
    Zhang, Xiong
    [J]. APPLIED THERMAL ENGINEERING, 2021, 185