REDUCING ABSORBED DOSE TO THYROID IN NECK CT EXAMINATIONS: THE EFFECTS OF SABA SHIELDING

被引:5
|
作者
Saba, Valiallah [1 ]
Shuraki, Jalal Kargar [2 ]
Valizadeh, Abdollah [1 ]
Zahedinia, Mohsen [2 ]
Barkhordari, Maziar [1 ]
机构
[1] Aja Univ Med Sci, Fac Paramed, Radiol Dept, Tehran, Iran
[2] Aja Univ Med Sci, Fac Med, Radiol Dept, Tehran, Iran
关键词
TUBE CURRENT MODULATION; FEMALE BREAST; IMAGE QUALITY; THORACIC CT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; REDUCTION; EYE; MDCT;
D O I
10.1093/rpd/ncaa153
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bi shielding has been used for the protection of radiosensitive organs during computed tomography (CT) for 20 years. In 2017, American Association of Physicists in Medicine recommended against Bi shielding due to its degrading effects on image quality. Saba shielding introduced recently protecting organs as Bi shielding without degrading image quality. In this study, the Saba shield was modified and primary radiation attenuation values of the shields and entrance skin dose (ESD) on the thyroid were measured with and without shielding. Furthermore, the quality of images obtained using Saba shielding was investigated quantitatively and qualitatively. Saba and Bi shielding reduced the ESD on the thyroid by about 50%. Saba shielding had about 5-7 HU less noise and about 51-65 HU less CT numbers shift in comparison with Bi shielding at a distance of 1 cm from the shields. Saba shielding had no degrading effects on image quality in the patient study.
引用
收藏
页码:349 / 360
页数:12
相关论文
共 50 条
  • [31] Usefulness of a lead shielding device for reducing the radiation dose to tissues outside the primary beams during CT
    Jae-Joon Chung
    Eun-Suk Cho
    Sung Min Kang
    Jeong-Sik Yu
    Dae Jung Kim
    Joo Hee Kim
    La radiologia medica, 2014, 119 : 951 - 957
  • [32] Usefulness of a lead shielding device for reducing the radiation dose to tissues outside the primary beams during CT
    Chung, Jae-Joon
    Cho, Eun-Suk
    Kang, Sung Min
    Yu, Jeong-Sik
    Kim, Dae Jung
    Kim, Joo Hee
    RADIOLOGIA MEDICA, 2014, 119 (12): : 951 - 957
  • [33] Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom
    Goren, A. D.
    Prins, R. D.
    Dauer, L. T.
    Quinn, B.
    Al-Najjar, A.
    Faber, R. D.
    Patchell, G.
    Branets, I.
    Colosi, D. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (06)
  • [34] Reducing Eye Lens Dose during Brain Perfusion CT Examinations by Moving the Scan Location or Tilting the Gantry Angle
    Zhang, D.
    Cagnon, C.
    DeMarco, J.
    Zankl, M.
    Turner, A.
    Khatonabadi, M.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3109 - +
  • [35] Discrepancy between absorbed dose estimated from phantom measurements and from estimates using data on individual head sizes in head CT examinations
    Adliene, D.
    Mockeviciene, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 186 - 190
  • [36] GANTRY ANGULATION EFFECTS ON CT DOSE ALONG THE Z-AXIS DIRECTION IN HEAD EXAMINATIONS
    Parsi, Masoumeh
    Sohrabi, Mehdi
    Mianji, Fereidoun
    Paydar, Reza
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (04) : 458 - 465
  • [37] Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
    Leswick, David A.
    Hunt, Megan M.
    Webster, Steven T.
    Fladeland, Derek A.
    RADIOLOGY, 2008, 249 (02) : 572 - 580
  • [38] Role of shielding in modulating the effects of solar particle events: Monte Carlo calculation of absorbed dose and DNA complex lesions in different organs
    Ballarini, F
    Biaggi, M
    De Biaggi, L
    Ferrari, A
    Ottolenghi, A
    Panzarasa, A
    Paretzke, HG
    Pelliccioni, M
    Sala, P
    Scannicchio, D
    Zankl, M
    SPACE LIFE SCIENCES: RADIATION RISK ASSESSMENT AND RADIATION MEASUREMENT IN LOW EARTH ORBIT, 2004, 34 (06): : 1338 - 1346
  • [39] Monte Carlo simulation study of the effect of thyroid shielding on radiation dose in dental cone beam CT in an adult male phantom
    Chen, Guolin
    Yin, Yuchen
    Sun, Liang
    Tang, Zichun
    Chen, Jianguo
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (20) : 1971 - 1980
  • [40] Transcriptional Response in Mouse Thyroid Tissue after 211At Administration: Effects of Absorbed Dose, Initial Dose-Rate and Time after Administration
    Rudqvist, Nils
    Spetz, Johan
    Schuler, Emil
    Parris, Toshima Z.
    Langen, Britta
    Helou, Khalil
    Forssell-Aronsson, Eva
    PLOS ONE, 2015, 10 (07):