Identification of Cross-Country Fault of Power Transformer for Fast Unblocking of Differential Protection
被引:17
|
作者:
Lin, Xiangning
论文数: 0引用数: 0
h-index: 0
机构:
Huazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R China
Three Gorges Univ, Coll Elect Engn & Informat Technol, Yichang 443002, Hubei Province, Peoples R ChinaHuazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R China
Lin, Xiangning
[1
,2
]
Weng, Hanli
论文数: 0引用数: 0
h-index: 0
机构:
Huazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R ChinaHuazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R China
Weng, Hanli
[1
]
Wang, Bin
论文数: 0引用数: 0
h-index: 0
机构:
Three Gorges Univ, Coll Elect Engn & Informat Technol, Yichang 443002, Hubei Province, Peoples R ChinaHuazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R China
Wang, Bin
[2
]
机构:
[1] Huazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Wuhan 430074, Peoples R China
[2] Three Gorges Univ, Coll Elect Engn & Informat Technol, Yichang 443002, Hubei Province, Peoples R China
Due to the different ratings of the current transformers (CT) located on different sides of power transformer, only the CT of low ratings will saturate when the power transformer experiences a heavy through fault, leading to false differential current. Such type of external fault can be identified from the internal one if the differential protection is equipped with the percentage restraint characteristic together with the method using operation time difference between pickup element and differential protection. However, the differential protection will be wrongly blocked as well if a cross-country fault occurs. According to the investigations in this paper, in the event of an external fault accompanied by the CT saturation, the variation of most samples of the secondary current of the saturated CT is inversely proportional to the variation of the differential current. Comparatively, this law cannot be followed on the occasion of an internal fault. In this case, the locus of the variation of the saturated secondary current with the differential current can be used to dynamically discriminate if an external fault develops to an internal fault. With the method proposed in this paper, the ability of the differential protection immune to cross-country fault can be improved further. The effectiveness of the proposed method is verified with the simulation tests.
机构:
Pontificia Univ Catolica Rio de Janeiro PUC Rio, 225 Marques de Sao Vicente St, BR-22451900 Rio De Janeiro, RJ, BrazilPontificia Univ Catolica Rio de Janeiro PUC Rio, 225 Marques de Sao Vicente St, BR-22451900 Rio De Janeiro, RJ, Brazil
机构:
Univ Ghent, Fac Econ & Business Adm, Sint Pieterspl 7, B-9000 Ghent, BelgiumUniv Ghent, Fac Econ & Business Adm, Sint Pieterspl 7, B-9000 Ghent, Belgium
Cerpentier, Maarten
Schulze, Anja
论文数: 0引用数: 0
h-index: 0
机构:
Univ Zurich, Dept Business Adm, Plattenstr 14, CH-8032 Zurich, SwitzerlandUniv Ghent, Fac Econ & Business Adm, Sint Pieterspl 7, B-9000 Ghent, Belgium
Schulze, Anja
论文数: 引用数:
h-index:
机构:
Vanacker, Tom
Zahra, Shaker A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Minnesota, Carlson Sch Management, 321 19th Ave South, Minneapolis, MN 55455 USAUniv Ghent, Fac Econ & Business Adm, Sint Pieterspl 7, B-9000 Ghent, Belgium