Second-order Zeeman frequency shift in the optically pumped cesium beam frequency standard with a dual servo system

被引:7
|
作者
Yang, SH [1 ]
Baek, KJ [1 ]
Kwon, TY [1 ]
Kim, YB [1 ]
Lee, HS [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Electromagnet Metrol, Taejon 305600, South Korea
关键词
second-order Zeeman effect; frequency shift; cesium beam frequency standard; uncertainty; magnetic field; servo system;
D O I
10.1143/JJAP.38.6174
中图分类号
O59 [应用物理学];
学科分类号
摘要
The second-order Zeeman effect produces the largest frequency shift among several causes to alter the reference frequency in the optically pumped cesium beam frequency standard. We introduce a novel way to reduce the uncertainties due to the Zeeman effect by adopting a dual servo system, one for stabilizing the current for static magnetic field and the other for normal clock operation. As a result, the combined uncertainty of the second-order Zeeman frequency shift is reduced to 3.2 x 10(-15), which is smaller by one order of magnitude than that without the servo system.
引用
收藏
页码:6174 / 6177
页数:4
相关论文
共 50 条
  • [31] PRELIMINARY-RESULTS OF AN OPTICALLY PUMPED CESIUM BEAM FREQUENCY STANDARD AT PEKING UNIVERSITY
    YANG, DH
    WANG, YQ
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (06) : 1000 - 1002
  • [32] SECOND ORDER DOPPLER SHIFT IN CESIUM BEAM ATOMIC FREQUENCY STANDARDS
    MUNGALL, AG
    METROLOGIA, 1971, 7 (02) : 49 - &
  • [33] Evaluation of second-order Zeeman frequency shift in NTSC-F2
    施俊如
    王心亮
    白杨
    杨帆
    管勇
    刘丹丹
    阮军
    张首刚
    Chinese Physics B, 2021, 30 (07) : 120 - 127
  • [34] Evaluation of second-order Zeeman frequency shift in NTSC-F2*
    Shi, Jun-Ru
    Wang, Xin-Liang
    Bai, Yang
    Yang, Fan
    Guan, Yong
    Liu, Dan-Dan
    Ruan, Jun
    Zhang, Shou-Gang
    CHINESE PHYSICS B, 2021, 30 (07)
  • [35] MEASUREMENTS ON OPTICALLY PUMPED CESIUM VAPOR FREQUENCY STANDARD.
    Bava, E.
    De Marchi, A.
    Rovera, G.
    Beverini, N.
    Strumia, F.
    Alta Frequenza, 1975, 44 (10): : 574 - 578
  • [36] MEASUREMENT OF THE SIGNAL-TO-NOISE RATIO IN AN OPTICALLY PUMPED CESIUM-BEAM FREQUENCY STANDARD
    GIORDANO, V
    HAMEL, A
    THEOBALD, G
    CEREZ, P
    AUDOIN, C
    CANDELIER, V
    METROLOGIA, 1988, 25 (01) : 17 - 20
  • [37] A new design of a diffused laser light optically pumped small cesium beam frequency standard
    Chen, JB
    Wang, FZ
    Wang, YQ
    Yang, DH
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (02) : 457 - 460
  • [38] Recent Progress on Commissioning an Optically Pumped Cesium Beam as Primary Frequency Standard at Brazilian NMI
    Gomes Tarelho, Luiz Vicente
    Garcia, Guilherme de Andrade
    Baratto, Antonio Carlos
    Lima de Souza, Rodolfo Saboia
    de Martin Junior, Jair
    Mueller, Stella Torres
    Magalhaes, Daniel Varela
    Bagnato, Vanderlei Salvador
    Bebeachibuli, Aida
    Rovera, Giovanni Daniele
    2014 European Frequency and Time Forum (EFTF), 2014, : 408 - 410
  • [39] FREQUENCY-SHIFT IN CESIUM BEAM FREQUENCY STANDARD BY RABI RESONANCE
    BECKER, G
    PTB-MITTEILUNGEN, 1977, 87 (04): : 288 - 295
  • [40] In-depth analysis of the frequency stability of optically pumped cesium beam frequency standards
    Guerandel, S.
    de Clercq, E.
    Barillet, R.
    Audoin, C.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4, 2007, : 1050 - 1055