The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models

被引:1
|
作者
Hartley, Olan [1 ]
Shanbhag, Tanvi [1 ]
Smith, Derek [2 ]
Grimm, Antonio [2 ]
Salameh, Ziad [3 ]
Tadakamadla, Santosh K. [4 ,5 ]
Alifui-Segbaya, Frank [1 ]
Ahmed, Khaled E. [1 ]
机构
[1] Griffith Univ, Sch Med & Dent, Ian OConnor Bldg G40, Gold Coast, Qld 4215, Australia
[2] Griffith Univ, Adv Design & Prototyping Technol Inst, Gold Coast, Qld 4215, Australia
[3] Lebanese Univ, Fac Dent Med, Beirut 1107, Lebanon
[4] La Trobe Univ, La Trobe Rural Hlth Sch, Dept Rural Clin Sci, Bendigo, Vic 3550, Australia
[5] La Trobe Univ, Violet Vines Marshman Ctr Rural Hlth Res, La Trobe Rural Hlth Sch, Bendigo, Vic 3550, Australia
关键词
3D printing; stacking; trueness; precision; accuracy; dental models; ORIENTATION; REPRODUCIBILITY; PACKING;
D O I
10.3390/polym14245465
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The objective of this study was to assess the effect of stacking on the dimensional and full-arch accuracy of 3D-printed models, utilising a standardised assessment methodology. A previously validated methodology involving a standard tessellation language image (STL) reference model, comprising seven spheres on a horseshoe base resembling a dental arch, was used. Six 3D-designed STL models were prepared, optimised, and stacked horizontally using 3D Sprint software. The stacking file was transferred to the NextDent 5100 printer to build the physical models. To assess accuracy, a coordinate measuring machine (CMM) measured the diameter of the spheres n=210, and twenty-one vectors extended between the centres of each of the seven spheres (n = 630). When compared to the reference model, significant differences were observed for dimensional (p = 0.006) and full-arch accuracy (p = 0.006) for all stacked models. Additionally, significant differences were observed between the stacked models for the dimensional accuracy between the posterior (p = 0.015), left posterior (p = 0.005) and anteroposterior (p = 0.002). The maximum contraction was observed in the fourth stacked model, which demonstrated the highest median deviation and least precision within the full-arch (MD = 666 mu m, IQR = 55 mu m), left posterior (MD = 136 mu m, IQR = 12 mu m), posterior (MD = 177 mu m, IQR = 14 mu m) and anteroposterior (MD = 179 mu m, IQR = 16 mu m) arch segments. In general, the anterior and left posterior arch segments recorded the highest contractions with a median deviation of 34 mu m and 29 mu m, and precision of 32 mu m and 22 mu m, respectively. Statistically significant differences were observed between the stacked models in terms of dimensional accuracy that were within clinically acceptable thresholds. The greatest contraction was noted in the fourth model, displaying the least full-arch accuracy compared to the other models. Stacked, additively manufactured, full arch models are a viable alternative for diagnostic, orthodontic, and single-unit prosthodontic applications. In contrast, caution should be exercised when utilising stacked models for full arch high accuracy prosthodontic applications. Further research is needed to assess the impact of additional variables including different printers and resins.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study)
    Husein, Hassan A.
    Morad, Mhd. Luai
    Kanout, Shaza
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [12] Dimensional Accuracy of 3D-Printed, Digital and Conventional Stone Dental Cast of Dentate Patients Using Arch and Teeth Measurements
    Al-Aali, Khulud A.
    Alshehri, Abeer R.
    Talic, Hiba R.
    Magan, Ayaan A.
    Alhomody, Felwa K.
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2023, 13 (07) : 803 - 807
  • [13] Accuracy of Successive Casts for Full-Arch Fixed Prostheses
    Dounis, Kiki S.
    Dounis, Georgia
    Ditmyer, Marcia M.
    Ziebert, Gerald J.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (05) : 446 - 449
  • [14] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694
  • [15] Factors Influencing the Dimensional Accuracy of 3D-Printed Full-Coverage Dental Restorations Using Stereolithography Technology
    Alharbi, Nawal
    Osman, Reham B.
    Wismeijer, Daniel
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (05) : 503 - 510
  • [16] Accuracy of full-arch scans using intraoral scanners
    Sebastian B. M. Patzelt
    Archontia Emmanouilidi
    Susanne Stampf
    Joerg R. Strub
    Wael Att
    Clinical Oral Investigations, 2014, 18 : 1687 - 1694
  • [17] Effect of Model Body Type and Print Angle on the Accuracy of 3D-Printed Orthodontic Models
    Lohfeld, Stefan
    Belnap, Bryndon
    Retrouvey, Jean-Marc
    Walker, Mary P.
    BIOMIMETICS, 2024, 9 (04)
  • [18] In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
    Ender, Andreas
    Mehl, Albert
    QUINTESSENCE INTERNATIONAL, 2015, 46 (01): : 9 - 17
  • [19] Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts
    Jang, Yeon
    Sim, Ji-Young
    Park, Jong-Kyoung
    Kim, Woong-Chul
    Kim, Hae-Young
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 135 - 142
  • [20] Immediate Loading Full-Arch 3D-Printed Implant-Supported Fixed Rehabilitation: A Case Report with 24-Month Follow-Up
    de Carvalho Formiga, Marcio
    Fuller, Renato
    Ardelean, Lavinia Cosmina
    Shibli, Jamil Awad
    MEDICINA-LITHUANIA, 2024, 60 (10):