Electrochemical Behavior of Three CP Titanium Dental Implants in Artificial Saliva

被引:7
|
作者
Kadowaki, Norma Terumi [1 ]
Santana Martinez, Gustavo Aristides [1 ]
Robin, Alain [1 ]
机构
[1] Univ Sao Paulo, Dept Mat Engn, LOM, EEL, BR-12600970 Lorena, SP, Brazil
关键词
dental implants; titanium; corrosion; electrochemical techniques; CORROSION BEHAVIOR; FLUORIDE; ALLOYS; RESISTANCE; FILM;
D O I
10.1590/S1516-14392009000300018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The electrochemical behavior of three titanium dental implants purchased on the Brazilian market was evaluated in artificial saliva using open-circuit potential measurements, electrochemical impedance spectroscopy and potentiodynamic polarization. The three implants are passive in this medium but their corrosion resistance and the stability of their passive oxide films are quite different. Although the three implants were made of commercially pure grade titanium, their corrosion current densities and passive current densities were shown to differ from one to two orders of magnitude.
引用
收藏
页码:363 / 366
页数:4
相关论文
共 50 条
  • [31] Electrochemical Behavior of a New Titanium Alloy for Dental Applications
    Mareci, Daniel
    Chelariu, Romeu
    Ivanescu, Steriana
    Gordin, Doina Margareta
    Cretescu, Igor
    Gloriant, Thierry
    REVISTA DE CHIMIE, 2009, 60 (08): : 787 - 793
  • [32] Electrochemical Behavior of Rejected Dental Implants in Peri-Implantitis
    Bunoiu, Ioana
    Andrei, Mihai
    Scheau, Cristian
    Manole, Claudiu Constantin
    Stoian, Andrei Bogdan
    Cioranu, Vladimir Sorin Ibric
    Didilescu, Andreea Cristiana
    COATINGS, 2020, 10 (03)
  • [33] ELECTROCHEMICAL-BEHAVIOR OF PALLADIUM ALLOYS ASSOCIATED WITH TITANIUM IMPLANTS
    LUGAND, P
    COLON, P
    PICARD, B
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 938 - 938
  • [34] Electrochemical study of corrosion behavior of titanium alloys for surgery implants
    Gorchakovskii, VK
    Shubkin, VN
    Gatiatulin, RR
    Pervyshina, EP
    PROTECTION OF METALS, 1997, 33 (03): : 284 - 285
  • [35] Development of an artificial saliva solution for studying the corrosion behavior of dental alloys
    Duffó, GS
    Castillo, EQ
    CORROSION, 2004, 60 (06) : 594 - 602
  • [36] Behavior of Two Dental Alloys as Ingot and Cast Crown in Artificial Saliva
    Porumb, Anca
    Brito-Garcia, Santiago
    Mirza-Rosca, Julia Claudia
    Fratila, Anca
    METALS, 2024, 14 (04)
  • [37] Corrosion Characterization of Titanium Alloys by Electrochemical Techniques in Artificial Saliva and SBF Solution
    Mariano, N. A.
    Oliveira, R. G.
    Braga, E.
    Rigo, E. C. S.
    BIOCERAMICS 21, 2009, 396-398 : 315 - 318
  • [38] Corrosion characterization of titanium alloys by electrochemical techniques in artificial saliva and SBF solution
    Mariano, N.A.
    Oliveira, R.G.
    Braga, E.I.
    Rigo, E.C.S.
    Key Engineering Materials, 2009, 396-398 : 315 - 318
  • [39] Influence of fluoride concentration and pH on corrosion behavior of titanium in artificial saliva
    Alain Robin
    Jeferson Paulino Meirelis
    Journal of Applied Electrochemistry, 2007, 37 : 511 - 517
  • [40] EFFECT OF FLUORIDE AND EUGENOL CONCENTRATION ON THE CORROSION BEHAVIOR OF TITANIUM IN ARTIFICIAL SALIVA
    Kinani, Latifa
    Chtaini, Abdelilah
    SCIENTIFIC STUDY AND RESEARCH-CHEMISTRY AND CHEMICAL ENGINEERING BIOTECHNOLOGY FOOD INDUSTRY, 2007, 8 (01): : 55 - 60