REMOVAL OF COPPER FROM DILUTED AQUEOUS SOLUTIONS USING AN IMINODIACETIC ACID CHELATING ION-EXCHANGE RESIN IN A FIXED-BED COLUMN

被引:0
|
作者
Bleotu, Irina [1 ]
Gilca, Emilia [1 ]
Dorneanu, Sorin-Aurel [1 ]
Catanas, Cosmin [1 ]
Ilea, Petru [1 ]
机构
[1] Univ Babes Bolyai, Fac Chemstry & Chem Engn, 11 Arany Janos Str, RO-400028 Cluj Napoca, Romania
来源
关键词
Copper removal; Fixed-bed column; Kinetics; Regeneration; WASTE-WATER; SELECTIVE REMOVAL; HEAVY-METALS; ADSORPTION; BIOSORPTION; BATCH; CHROMIUM; SORPTION; CU(II); CARBON;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, the copper removal was investigated in a fixed-bed column using a iminodiacetic acid chelating ion exchange resin (Purolite S930Plus). The influence of the resin bed height (3-6 cm) over the removal process was evaluated at a flow rate of 5 mL/min and initial Cu(II) concentration of 0.8 mM. The obtained results were analysed by linear regression using the most common sorption kinetic models such as Yoon-Nelson, Adam-Bohart, and Clark. The experimental data were in good agreement with Yoon and Nelson model. Also, scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) were employed to study the morphologies and the composition of the resin surface before and after sorption. The column regeneration studies were performed using 3 N H2SO4 solution. The tested resin presented a good regeneration capacity and can be successfully used to remove copper ions from diluted wastewaters.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [41] Magnetic fixed-bed column for Cr(VI) removal from aqueous solution using schwertmannite
    Eskandarpour, Akbar
    Onyang, Maurice S.
    Tanahashi, Mitsuru
    Ochieng, Aoyi
    Bando, Yoshiyuki
    Iwai, Kazuhiko
    Okido, Masazumi
    Asai, Shigeo
    ISIJ INTERNATIONAL, 2008, 48 (02) : 240 - 244
  • [42] CALCIUM REMOVAL FROM SEA WATER BY FIXED-BED ION EXCHANGE
    KLEIN, G
    CHERNEY, S
    RUDDICK, EL
    VERMEULE.T
    DESALINATION, 1968, 4 (02) : 158 - &
  • [43] Application of mathematical models for ion-exchange removal of calcium ions from potassium chromate solutions by Amberlite IRC 748 resin in a continuous fixed bed column
    Yu, Zhihui
    Qi, Tao
    Qu, Jingkui
    Guo, Yingchao
    HYDROMETALLURGY, 2015, 158 : 165 - 171
  • [44] Removal of copper (II) from aqueous solution using granular sodium alginate/activated carbon hydrogel in a fixed-bed column
    Adhami, Leila
    Mirzaei, Masoomeh
    DESALINATION AND WATER TREATMENT, 2018, 103 : 208 - 215
  • [45] Fixed-bed study for copper (II) removal from aqueous solutions by marine alga Durvillaea potatorum
    Yu, Q
    Kaewsarn, P
    ENVIRONMENTAL TECHNOLOGY, 1999, 20 (09) : 1005 - 1008
  • [46] Fixed-bed column study for the removal of Ag(I)and Cr(III)from aqueous solutions using puffed rice husk
    Wu, Yan
    Deng, Zaifang
    Tao, Yang
    Luo, Xuegang
    APPLICATIONS OF ENGINEERING MATERIALS, PTS 1-4, 2011, 287-290 : 1620 - +
  • [47] Removal of Cd(II) Ions from Aqueous Solutions Using Immobilized Spent Substrates of Pleurotus ostreatus in a Fixed-Bed Column
    Qu, Juanjuan
    Li, Yue
    Zang, Tingting
    Jin, Yu
    Liu, Xuesheng
    Yan, Lei
    ENVIRONMENTAL ENGINEERING SCIENCE, 2019, 36 (09) : 1162 - 1169
  • [48] Removal of heavy metal ions from aqueous solutions by synthetic apatites using the column ion-exchange method
    de Freitas, JS
    Salomao, GC
    Gomes, MDT
    ECLETICA QUIMICA, 2000, 25 : 19 - 29
  • [49] Removal of Acetic Acid from Fuel Ethanol Using Ion-Exchange Resin
    Lv, Huisheng
    Sun, Yanpeng
    Zhang, Minhua
    Geng, Zhongfeng
    Ren, Miaomiao
    ENERGY & FUELS, 2012, 26 (12) : 7299 - 7307
  • [50] Adsorption Kinetics and Isotherms for the Removal of Zinc Ions from Aqueous Solutions by an Ion-Exchange Resin
    Fil, Baybars Ali
    Boncukcuoglu, Recep
    Yilmaz, Alper Erdem
    Bayar, Serkan
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2012, 34 (04): : 841 - 848