Absence of atherosclerosis in intramyocardial coronary artery segments: large group in-vivo evaluation with 16-slice computer tomography angiography

被引:0
|
作者
Dvir, D [1 ]
Gasper, T [1 ]
Peled, N [1 ]
Aravot, D [1 ]
机构
[1] Carmel Hosp, Haifa, Israel
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:336 / 337
页数:2
相关论文
共 50 条
  • [31] Optimal reconstruction protocol for noninvasive coronary angiography with 16-slice multidetector-row computed tomography
    Sanz, J
    Rius, T
    Kuschnir, P
    Salguero, R
    Fuster, V
    Poon, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 329A - 329A
  • [32] Coronary artery disease cannot be reliably evaluated by 16-slice multidetector spiral computed tomography
    Bartnes, Kristian
    Sildnes, Trude
    Iqbal, Amjid
    Dahl-Eriksen, Oystein
    Trovik, Thor
    Steigen, Terje Kristian
    Mortensen, Rica
    Mannsverk, Jan Torbjorn
    Sorlie, Dag Glen
    Myrmel, Truls
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2007, 41 (03) : 167 - 170
  • [33] 64-versus 16-slice CT angiography for coronary artery stent assessment -: In vitro experience
    Seifarth, H
    Özgün, M
    Raupach, R
    Flohr, T
    Heindel, W
    Fischbach, R
    Maintz, D
    INVESTIGATIVE RADIOLOGY, 2006, 41 (01) : 22 - 27
  • [34] Coronary artery fistula with an associated aneurysm detected by 16-slice multidetector row computed tomographic angiography
    Hisao Hara
    Masao Moroi
    Tadashi Araki
    Taeko Kunimasa
    Taro Tsunoda
    Makoto Suzuki
    Kaoru Sugi
    Masato Nakamura
    Heart and Vessels, 2005, 20 : 184 - 185
  • [35] Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter
    Harald Seifarth
    Rainer Raupach
    Stefan Schaller
    Eva Maria Fallenberg
    Thomas Flohr
    Walter Heindel
    Roman Fischbach
    David Maintz
    European Radiology, 2005, 15 : 721 - 726
  • [36] Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter
    Seifarth, H
    Raupach, R
    Schaller, S
    Fallenberg, EM
    Flohr, T
    Heindel, W
    Fischbach, R
    Maintz, D
    EUROPEAN RADIOLOGY, 2005, 15 (04) : 721 - 726
  • [37] Coronary artery fistula with an associated aneurysm detected by 16-slice multidetector row computed tomographic angiography
    Hara, H
    Moroi, M
    Araki, T
    Kunimasa, T
    Tsunoda, T
    Suzuki, M
    Sugi, K
    Nakamura, M
    HEART AND VESSELS, 2005, 20 (04) : 184 - 185
  • [38] DIAGNOSTIC PERFORMANCE OF 16-SLICE VERSUS DUAL SOURCE 64-SLICE MDCT ANGIOGRAPHY IN THE EVALUATION OF CORONARY ARTERY BYPASS GRAFTS: A COMPARATIVE STUDY
    Sahiner, L.
    Yorgun, H.
    Canpolat, U.
    Hazirolan, T.
    Aytemir, K.
    Oto, A.
    Karcaaltincaba, M.
    Akata, D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S59 - S59
  • [39] The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography
    Sanz, J
    Rius, T
    Kuschnir, P
    Fuster, V
    Goldberg, J
    Ye, XY
    Wisdom, P
    Poon, M
    INVESTIGATIVE RADIOLOGY, 2005, 40 (03) : 155 - 163
  • [40] Image quality of 16-slice computed tomography coronary angiography in patients with complete left bundle branch block
    Jankauskas, Antanas
    Zaveckiene, Jurgita
    Pundziute, Gabija
    Slapikas, Rimvydas
    Basevicius, Algidas
    Zaliunas, Remigijus
    MEDICINA-LITHUANIA, 2009, 45 (01): : 14 - 20