Detection of 27 molecules in a single injection volume by hadamard transform capillary electrophoresis

被引:18
|
作者
Kaneta, T [1 ]
Kosai, K [1 ]
Imasaka, T [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Fukuoka 8128581, Japan
关键词
D O I
10.2116/analsci.19.1659
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A concentration detection limit of 100 fM was achieved for the fluorescein ion by improving the experimental setup used for Hadamard transform capillary electrophoresis. Two argon-ion lasers, a gating laser for sample injection and a probe laser for the excitation of analyte molecules, were employed for the efficient photodegradation of analyte molecules in laser-induced fluorescence detection using an optically gated sample-injection method. In addition, a dichroic mirror, located in the pathway of the probe laser was used to exclude the other lines of the argon-ion laser. Using a Hadamard matrix on the order of 2046, the concentration limit of detection for fluorescein ion was determined to be 100 fM at S/N = 3, in which the average number of molecules in a single injection volume was calculated to be 27. The influences of the output power in both the gating and probe lasers on the sensitivity are also discussed.
引用
收藏
页码:1659 / 1661
页数:3
相关论文
共 50 条
  • [1] Detection of 27 Molecules in a Single Injection Volume by Hadamard Transform Capillary Electrophoresis
    Takashi Kaneta
    Kazuki Kosai
    Totaro Imasaka
    Analytical Sciences, 2003, 19 : 1659 - 1661
  • [2] Hadamard transform capillary electrophoresis
    Kaneta, T
    Yamaguchi, Y
    Imasaka, T
    ANALYTICAL CHEMISTRY, 1999, 71 (23) : 5444 - 5446
  • [3] Hadamard transform capillary electrophoresis.
    Kaneta, T
    ANALYTICAL CHEMISTRY, 2001, 73 (19) : 540A - 547A
  • [4] Hadamard transform capillary electrophoresis combined with absorption spectrometry
    Hata, K
    Kaneta, T
    Imasaka, T
    ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4421 - 4425
  • [5] Ultratrace analysis based on Hadamard transform capillary electrophoresis
    Kaneta, T
    Kosai, K
    Imasaka, T
    ANALYTICAL CHEMISTRY, 2002, 74 (10) : 2257 - 2260
  • [6] Hadamard transform capillary electrophoresis combined with laser-induced fluorometry using electrokinetic injection
    Hata, K
    Kaneta, T
    Imasaka, T
    ANALYTICA CHIMICA ACTA, 2006, 556 (01) : 178 - 182
  • [7] Influence of a stacking phenomenon on the results of Hadamard transform capillary electrophoresis
    Seiman, A.
    Kaljurand, M.
    Ebber, A.
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 71 - 75
  • [8] Direct Hadamard Transform Capillary Zone Electrophoresis without Instrumental Modifications
    Pallmann, Sebastian
    Siegle, Alexander F.
    Steflova, Jana
    Trapp, Oliver
    ANALYTICAL CHEMISTRY, 2018, 90 (14) : 8445 - 8453
  • [9] Capillary electrophoresis and capillary flow injection analysis with electrochemical detection
    Matysik, FM
    Backofen, U
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (3-4): : 169 - 172
  • [10] On-capillary chemiluminescence detection for capillary electrophoresis with a single capillary
    Zhang, Cheng-Jie
    Wu, Xing-Zheng
    ANALYTICAL SCIENCES, 2007, 23 (06) : 743 - 746