A 3D-conformal technique is better than IMRT or VMAT for lung SBRT

被引:24
|
作者
Cai, Jing [1 ]
Malhotra, Harish K. [2 ]
Orton, Colin G.
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Roswell Pk Canc Inst, Dept Radiat Med, Buffalo, NY 14263 USA
关键词
BODY RADIATION-THERAPY; MODULATED ARC THERAPY; TUMOR MOTION; CANCER; RADIOTHERAPY; BEAMS; DELIVERY;
D O I
10.1118/1.4856175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
[No abstract available]
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Comparison of toxicity after IMRT and 3D-conformal radiotherapy for patients with pancreatic cancer - A systematic review
    Bittner, Martin-Immanuel
    Grosu, Anca-Ligia
    Brunner, Thomas B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 114 (01) : 117 - 121
  • [32] Clinical implications of 3D-conformal radiotherapy
    Liesenfeld, SM
    Wendt, TG
    [J]. ONKOLOGIE, 2000, 23 (06): : 590 - 592
  • [33] COMPARISON OF HYBRID TECHNIQUES WITH 3D-CONFORMAL RADIOTHERAPY IN PATIENTS WITH LUNG CANCER
    Azaklioglu, Oemer
    Akcay, Dogukan
    Er, Ilhami
    Akguengoer, Kadir
    Demiral, Ayse Nur
    [J]. JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2023, 7 (03): : 50 - 57
  • [34] A Quantitative Approach to Analyze the Necessity of Robust Optimization for IMRT and VMAT Treatments of Lung SBRT
    Wang, Y.
    Zieminski, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E276 - E276
  • [35] 3D dose verification of VMAT lung SBRT using Mobius3D
    Loo, M. Van Het
    Welleweerd, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S423 - S424
  • [36] The Impact of Density Overrides in IMRT and VMAT Planning for Lung Cancer Patients Treated SBRT
    Qin, Y.
    Chetty, I.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3588 - 3588
  • [37] Dosimetric Influence of Jaw Tracking Option On Lung SBRT Using VMAT and IMRT Techniques
    Amoush, A.
    Ferjani, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3108 - 3108
  • [38] Conformal inverse planned ARCS vs IMRT ARCS for sbrt lung lesions
    Nguyen, L.
    Szegedi, W.
    Esquivel, C.
    Papanikolaou, N.
    Rasiah-Szegedi, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S205 - S206
  • [39] 3D-Conformal RT, Fixed-Field IMRT and Rapid Arc, Which One is Better for Esophageal Carcinoma Treated with Elective Nodal Irradiation
    Wang, D.
    Yang, Y.
    Zhu, J.
    Li, B.
    Chen, J.
    Yin, Y.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2011, 10 (05) : 487 - 494
  • [40] 4D-VMAT Vs. Gated VMAT in Lung Cancer SBRT
    Chin, E.
    Loewen, S.
    Sahota, H.
    Nichol, A.
    Heath, E.
    Otto, K.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3852 - 3852