Intraoperative fractures of the acetabulum during primary total hip arthroplasty

被引:71
|
作者
Haidukewych, George J.
Jacofsky, David J.
Hanssen, Arlen D.
Lewallen, David G.
机构
[1] Florida Orthoped Inst, Temple Terrace, FL 33637 USA
[2] Mayo Clin, Rochester, MN 55901 USA
来源
关键词
D O I
10.2106/JBJS.E.00890
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The intraoperative occurrence of an acetabular fracture is a rare complication of primary total hip arthroplasty. Previous reports have lacked a sufficiently large number of subjects to allow for an analysis of the causes and appropriate treatment of this problem. Methods: Between 1990 and 2000, 7121 primary total hip arthroplasties were performed at our institution. We retrospectively reviewed the records in our Total Joint Registry and found that twenty-one patients (twenty-one hips) had sustained an intraoperative acetabular fracture. Nineteen of these patients (nineteen hips) had been followed until revision or for a minimum of two years (mean duration of follow-up, forty-four months). We evaluated the anatomic location, cause, treatment, and outcome of the fractures. Acetabular component designs were categorized as modular, nonmodular (monoblock), true hemispherical, or elliptical, and then each design was analyzed for fracture risk. Results: No fractures occurred in association with cemented acetabular components. The fracture rate associated with uncemented components was 0.4%. In seventeen hips, the acetabular component was judged to be stable despite the detection of a fracture and the cup was retained. In four hips, the original cup was not stable and therefore was replaced with a design that allowed for supplemental screw fixation. All fractures united, and all cups demonstrated osseous ingrowth at the time of the most recent follow-up. Elliptical monoblock cups were associated with a significantly higher fracture rate than were elliptical modular cups (p < 0.0001) and hemispherical modular cups (p < 0.0001). There was no significant difference between elliptical modular and hemispherical modular components with regard to the fracture rate. Conclusions: Acetabular fracture during primary total hip arthroplasty is a rare complication of acetabular fixation without cement. In the present series, retention of a stable cup was associated with uneventful osseous ingrowth and excellent early-term outcomes. We found a high rate of fracture in association with the use of monoblock elliptical components. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1952 / 1956
页数:5
相关论文
共 50 条
  • [21] An Analytical Approach to Study the Intraoperative Fractures of Femoral Shaft During Total Hip Arthroplasty
    Malekmotiei, Leila
    Farahmand, Farzam
    Shodja, Hossein M.
    Samadi-Dooki, Aref
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (04):
  • [22] Accuracy of intraoperative cultures in primary total hip arthroplasty
    Picado, C. H. F.
    Garcia, F. L.
    Chagas, M. V., Jr.
    Toquetao, F. G.
    [J]. HIP INTERNATIONAL, 2008, 18 (01) : 46 - 50
  • [24] INTRAOPERATIVE COMPLICATIONS DURING TOTAL HIP-ARTHROPLASTY
    PATTERSON, BM
    LIEBERMAN, JR
    SALVATI, EA
    [J]. ORTHOPEDICS, 1995, 18 (11) : 1089 - 1095
  • [25] Total hip arthroplasty after osteosynthesis of proximal femoral fractures compared to primary Total hip arthroplasty
    Schleicher, Alisa
    Neidenbach, Philipp
    Blumel, Stefan
    Leunig, Michael
    Rudiger, Hannes
    [J]. SWISS MEDICAL WEEKLY, 2021, 151 : 22S - 22S
  • [26] Hammering sound frequency analysis and prevention of intraoperative periprosthetic fractures during total hip arthroplasty
    Sakai, Rina
    Kikuchi, Aki
    Morita, Towa
    Takahira, Naonobu
    Uchiyama, Katsufumi
    Yamamoto, Takeaki
    Moriya, Mistutoshi
    Uchida, Kentaro
    Fukushima, Kensuke
    Tanaka, Kensei
    Takaso, Masashi
    Itoman, Moritoshi
    Mabuchi, Kiyoshi
    [J]. HIP INTERNATIONAL, 2011, 21 (06) : 718 - 723
  • [27] INTRAOPERATIVE FEMORAL FRACTURES ASSOCIATED WITH CEMENTLESS TOTAL HIP-ARTHROPLASTY
    MALLORY, TH
    KRAUS, TJ
    VAUGHN, BK
    [J]. ORTHOPEDICS, 1989, 12 (02) : 231 - 239
  • [28] Cerclage wire or positional cortical screw for the treatment of intraoperative calcar fractures during primary total hip arthroplasty? A biomechanical study
    Gauthier, Paul
    Slulitel, Pablo
    Speirs, Andrew
    Laude, Frederic
    Gofton, Wade T.
    Beaule, Paul E.
    [J]. CLINICAL BIOMECHANICS, 2023, 101
  • [29] Management of intraoperative acetabular fracture in primary total hip arthroplasty
    Li, Juncheng
    Ji, Quanbo
    Ni, Ming
    Zheng, Qingyuan
    Sun, Jingyang
    Zhang, Guoqiang
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [30] Intraoperative Measurement of Femoral Offset in Primary Total Hip Arthroplasty
    Iqbal, Shoaib
    Datir, Sandeep
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (04) : E15 - E16