Value of three-dimensional speckle-tracking imaging in detecting left ventricular systolic function in patients with dilated cardiomyopathy

被引:11
|
作者
He, Jionghong [1 ]
Yang, Long [1 ]
机构
[1] Guizhou Prov Peoples Hosp, Dept Cardiol, Guiyang 550002, Guizhou, Peoples R China
关键词
dilated cardiomyopathy; echocardiography; left ventricular systolic function; magnetic resonance imaging; three-dimensional speckle-tracking imaging; ECHOCARDIOGRAPHY;
D O I
10.1111/echo.14427
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To explore the value of three-dimensional speckle-tracking imaging (3DSTI) in detecting left ventricular systolic function in patients with dilated cardiomyopathy (DCM). Methods Totally 31 DCM patients were enrolled in this study. Left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured using the 3DSTI, two-dimensional echocardiography (2DE), and magnetic resonance imaging (MRI). Left ventricular end-diastolic mass (EDmass) and left ventricular end-diastolic mass index (LVEDmass I) were also detected by 3DSTI and MRI. The differences in these measurements were analyzed and compared. Results The values of LVESV, LVEDV, and LVEF showed significantly positive correlations among 2DE group, 3DSTI group, and MRI group. The LVEF value showed significant difference among these three groups [(33.3 +/- 11.1)%, (30.3 +/- 10.6)%, and (26.2 +/- 10.7)%; P = 0.04], whereas LVEDV and LVESV values were not significantly different (P > 0.05; respectively). Inter-group comparison showed the mean of LVEF was significantly lower in MRI group than in 2DE group (P = 0.031), whereas there was no significant difference between 2DE group and 3DSTI group and between 3DSTI group and MRI group (P > 0.05; respectively). The EDmass and EDmassI detected by 3DSTI and MRI were (143.2 +/- 40.2) g vs (190.0 +/- 58.3) g and (83.2 +/- 21.1) g/m(2) vs (110.1 +/- 29.7) g/m(2) (P < 0.001; respectively). Conclusions The LVEF value detected by 3DSTI is closer to that detected by MRI in DCM patients.
引用
收藏
页码:1492 / 1495
页数:4
相关论文
共 50 条
  • [1] Evaluation of Left Ventricular Systolic Function in Patients with Coronary Microvascular Dysfunction by Three-Dimensional Speckle-Tracking Imaging
    Yu, Ziheng
    Pan, Hongfen
    Cheng, Zhenfeng
    Lu, Kongjie
    Hu, Huanhuan
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 37 (03) : 321 - 327
  • [2] Left Ventricular Dyssynchrony Using Three-Dimensional Speckle-Tracking Imaging as a Determinant of Torsional Mechanics in Patients With Idiopathic Dilated Cardiomyopathy
    Matsumoto, Kensuke
    Tanaka, Hidekazu
    Tatsumi, Kazuhiro
    Miyoshi, Tatsuya
    Hiraishi, Mana
    Kaneko, Akihiro
    Tsuji, Takayuki
    Ryo, Keiko
    Fukuda, Yuko
    Yoshida, Akihiro
    Kawai, Hiroya
    Hirata, Ken-Ichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (08): : 1197 - 1205
  • [3] Imaging characteristics of left ventricular diastolic function in patients with dilated cardiomyopathy using three-dimensional speckle tracking imaging and MRI
    Xu, Yingjie
    Zhu, Jing
    MINERVA MEDICA, 2023,
  • [4] Value of Three-Dimensional Speckle-Tracking in Detecting Left Ventricular Dysfunction in Patients with Aortic Valvular Diseases
    Li, Chun-mei
    Li, Chen
    Bai, Wen-juan
    Zhang, Xiao-ling
    Tang, Hong
    Qing, Zhang
    Li, Rao
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (11) : 1245 - 1252
  • [5] Left Ventricular Function in Patients on Maintenance Hemodialysis : A Three-Dimensional Speckle-Tracking Imaging Study
    Chen, Meihua
    Chen, Xiaojuan
    Huang, Hanyin
    Wei, Yunpeng
    Wang, Lehua
    Huang, Xuning
    CARDIORENAL MEDICINE, 2023, 13 (01) : 248 - 258
  • [6] Assessment of left ventricular systolic function in patients with iron deficiency anemia by three-dimensional speckle-tracking echocardiography
    Zhou, Qiao
    Shen, Jiaqi
    Liu, Yue
    Luo, Runlan
    Tan, Bijun
    Li, Guangsen
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 18 (03): : 194 - 199
  • [7] Evaluation of global left ventricular systolic function in patients with heart failure using three-dimensional speckle-tracking echocardiography
    Luo, X. X.
    Fang, F.
    Lee, P. W.
    Li, S.
    Zhang, Z. H.
    Lam, Y. Y.
    Sanderson, J. E.
    Kwong, J. S. W.
    Yu, C. M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S21 - S22
  • [8] Evaluation of Global Left Ventricular Systolic Function Using Three-Dimensional Echocardiography Speckle-Tracking Strain Parameters
    Reant, Patricia
    Barbot, Laurence
    Touche, Cecile
    Dijos, Marina
    Arsac, Florence
    Pillois, Xavier
    Landelle, Mathieu
    Roudaut, Raymond
    Lafitte, Stephane
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 68 - 79
  • [9] Incremental Value of Three- dimensional Speckle-tracking Echocardiography for Evaluating Left Ventricular Systolic Function in Patients with Coronary Slow Flow
    Liu, Shuo
    Wang, Yonghuai
    Li, Jun
    Li, Guangyuan
    Kong, Fanxin
    Mu, Lixin
    Jia, Dalin
    Li, Yuhong
    Yang, Jun
    Ma, Chunyan
    CURRENT PROBLEMS IN CARDIOLOGY, 2022, 47 (09)
  • [10] Clinical Study of Left Ventricular Global Systolic Function in Patients with Hypertension by Three-Dimensional Ultrasound Speckle Tracking Imaging
    Li, Y. M.
    Xie, M. X.
    Lv, Q.
    Fu, Q.
    Fang, L. Y.
    Jiang, L.
    Li, W.
    Qin, X. J.
    CARDIOLOGY, 2010, 117 : 105 - 105