Maximum Quasi-Static Indentation Stress Analysis of Flax/Epoxy and Glass/Epoxy Polymer Composites

被引:0
|
作者
Azhar, Ilya Izyan Shahrul [1 ]
Jumahat, Aidah [2 ,3 ]
Rahman, Noor Leha Abdul [2 ]
Khiari, Ramzi [4 ]
Nasir, Muhammad Afnan Jamal Abd [2 ]
机构
[1] Univ Teknol MARA, Coll Engn, Kampus Pasir Gudang, Bandar Seri Alam 81750, Johor, Malaysia
[2] Univ Teknol MARA, Coll Engn, Sch Mech Engn, Shah Alam 40450, Selangor, Malaysia
[3] Univ Teknol MARA, Inst Infrastruct Engn & Sustainable Management, Shah Alam, Selangor, Malaysia
[4] Fac Sci Monastir, Lab Environm Chem & Cleaner Proc, Monastir 5000, Tunisia
来源
关键词
Fibre reinforced polymer composite; flax; quasi -static indentation; finite element analysis; ANSYS; FLAX FIBERS; CEMENTITIOUS COMPOSITES; L;
D O I
10.30880/ijie.2022.14.09.001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of fibres is constantly expanding to satisfy the demands of various industries. Both synthetic and natural fibres offer benefits that are best suited to specific applications. Synthetic fibres are preferable than the natural fibres because they have greater mechanical properties. However, in their application, synthetic fibres negatively influence the environment as they are non-biodegradable material. As a result, the demand and usage of natural fibres keep increasing as an alternative to the synthetic fibres. The usage of natural fibres reduces negative impact on the environmental, though their properties are not as good as synthetic fibres. ANSYS APDL, one of the FEA analysis software, is used to perform quasi-static indentation (QSI) test modelling in this research work. The purpose of this study is to determine the influence of fibre orientations of 0 degrees, 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees, and 90 degrees, as well as the effect of the supporting ply angle, 0 degrees, on the mechanical properties of Flax FRP composite. For layup sequences of [(+0,-0)2] S and [(+/- 0)2,04] S, it was observed that maximum strength increases from 0 degrees to 90 degrees fibre orientation. Meanwhile, in a QSI test, the highest strength of Flax FRP was found at 45 degrees for both [(+0,-0)2] S and [(+/- 0)2,04] S layup sequences, with 94.20 MPa and 96.80 MPa, respectively. The effect of fibre volume fraction (Vf), such as Glass FRP composites with fibre volume fractions of 30% and 60%, shows that the fibre volume fraction for 60% has a better performance than 30%. Therefore, composites with a higher fibre volume fraction show better maximum strength and lower deformability. The results of modelling and simulation work on Flax FRP composites can aid in developing new materials that are more sustainable than conventional techniques by anticipating the mechanical behaviour of natural FRP composites.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [21] Quasi-static indentation properties of damaged glass/epoxy composite laminates repaired by the application of intra-ply hybrid patches
    Andrew, J. Jefferson
    Arumugam, V.
    Ramesh, C.
    Poorani, S.
    Santulli, C.
    POLYMER TESTING, 2017, 61 : 132 - 145
  • [22] The influence of graphene reinforced electrospun nano-interlayers on quasi-static indentation behavior of fiber-reinforced epoxy composites
    M. Goodarz
    S. H. Bahrami
    M. Sadighi
    S. Saber-Samandari
    Fibers and Polymers, 2017, 18 : 322 - 333
  • [23] The Influence of Graphene Reinforced Electrospun Nano-Interlayers on Quasi-Static Indentation Behavior of Fiber-Reinforced Epoxy Composites
    Goodarz, M.
    Bahrami, S. H.
    Sadighi, M.
    Saber-Samandari, S.
    FIBERS AND POLYMERS, 2017, 18 (02) : 322 - 333
  • [24] Effect of post-cure temperature and different reinforcements in adhesive bonded repair for damaged glass/epoxy composites under multiple quasi-static indentation loading
    Andrew, J. Jefferson
    Arumugam, V.
    Santulli, C.
    COMPOSITE STRUCTURES, 2016, 143 : 63 - 74
  • [25] Effect of solution-blown nanofibrous web on quasi-static punch shear test results and quasi-static indentation behavior of carbon fiber-reinforced epoxy matrix composites
    Ayten, Ali Imran
    Polat, Yusuf
    Sahbaz, Mehmet
    Seyhan, Aybeniz
    JOURNAL OF COMPOSITE MATERIALS, 2023, 57 (24) : 3865 - 3875
  • [26] Are there similarities between quasi-static indentation and low velocity impact tests for flax-fibre composites?
    Leroy, Adelaide
    Scida, Daniel
    Roux, Emile
    Toussaint, Franck
    Ayad, Rezak
    INDUSTRIAL CROPS AND PRODUCTS, 2021, 171
  • [27] Quasi-static and dynamic properties of unidirectional glass fiber/epoxy laminate for structural strengthening
    Xuejie Zhang
    Honglong Wang
    Yang Lv
    Jie Li
    Materials and Structures, 2022, 55
  • [28] Quasi-static and dynamic properties of unidirectional glass fiber/epoxy laminate for structural strengthening
    Zhang, Xuejie
    Wang, Honglong
    Lv, Yang
    Li, Jie
    MATERIALS AND STRUCTURES, 2022, 55 (07)
  • [29] Infrared Thermography for Inline Monitoring of Glass/Epoxy under Impact and Quasi-Static Bending
    Meola, Carosena
    Boccardi, Simone
    Carlomagno, Giovanni Maria
    APPLIED SCIENCES-BASEL, 2018, 8 (02):
  • [30] Correction to: Quasi-Static Penetration Behavior of Glass-Fiber-Reinforced Epoxy Nanocomposites
    G. Demircan
    M. Kisa
    M. Ozen
    A. Acikgoz
    Mechanics of Composite Materials, 2021, 57 : 719 - 719