Experimental study on the effect of pool fire area and violent fuel boiling on fuel burning state evolution in compartment fire

被引:10
|
作者
Wang, Dong [1 ]
Zhou, Xiaodong [1 ]
Gui, Jia [1 ]
Ju, Xiaoyu [2 ]
Ye, Kai [3 ]
Zhou, Zhizuan [1 ]
Cao, Junda [1 ]
Zheng, Yuan [1 ]
Cao, Bei [1 ]
Yang, Lizhong [1 ]
Peng, Fei [1 ,4 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Toyohashi Univ Technol, Dept Mech Engn, Tempaku Ku, 1-1 Hibarigaoka, Toyohashi, Aichi 4418580, Japan
[3] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore 639798, Singapore
[4] Changsha Univ Sci & Technol, Coll Energy & Power Engn, Changsha 410114, Hunan, Peoples R China
关键词
Ventilation-controlled compartment fire; Opening factor; Burning rate; Indoor temperature; Facade flame; Violent boiling; THIN-LAYER BOILOVER; BEHAVIOR; HEIGHTS;
D O I
10.1016/j.fuel.2020.118933
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Experiments were conducted to elucidate the impact of pool area and violent liquid fuel boiling on a compartment fire evolution and facade flame. The experiments were performed in a 1/2 reduced-scale compartment, with several different-sized openings and pools. The temperatures at the inner and outer corners of the compartment, the fuel mass loss rate and the height of the facade flame ejected from the opening were analyzed. As the ratio of pool area to opening factor gradually increased, both the temperature variations at the inner and outer corners underwent three stages after the fuel boiled violently. The slope of the mass flow rate of air inflow with the burning rate gradually decreased to 8.43 as the fuel area increased. It was found that fuel pyrolysis rate was determined by opening factor and fuel area in a ventilation-controlled fire. Data from other researcher was used to verify that this inference was also applicable to different fuels. A new characteristic length was proposed to explain the evolution of facade flame height when there was a temperature difference in the enclosure.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Experimental study on burning behavior of crude oil pool fire in annular ice cavities
    Kong, Depeng
    Zhang, Zhen
    Ping, Ping
    Chen, Guoming
    He, Xu
    Yang, Hanbing
    FUEL, 2018, 234 : 464 - 472
  • [32] Experimental study and numerical simulation on the temperature distribution of oil-pool-fire burning
    Fu, Su-Hong
    Cao, Guang-Jun
    Li, Ji-Feng
    Zhang, Dong-Sheng
    Li, Lei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (08): : 1411 - 1414
  • [33] The Effect of Fuel Rotation on Different Characteristics of Fire Whirls: An Experimental Analysis
    Vishwakarma, Pushpendra Kumar
    Mishra, Saumitra
    Mishra, Kirti Bhushan
    Kumar, A. Aravind
    FIRE TECHNOLOGY, 2023, 59 (05) : 2587 - 2619
  • [34] The Effect of Fuel Rotation on Different Characteristics of Fire Whirls: An Experimental Analysis
    Pushpendra Kumar Vishwakarma
    Saumitra Mishra
    Kirti Bhushan Mishra
    A. Aravind Kumar
    Fire Technology, 2023, 59 : 2587 - 2619
  • [35] An experimental study on the effect of ventilation velocity on burning rate in tunnel fires-heptane pool fire case
    Roh, Jae Seong
    Yang, Seung Shin
    Ryou, Hong Sun
    Yoon, Myong O.
    Jeong, Youn Tae
    BUILDING AND ENVIRONMENT, 2008, 43 (07) : 1225 - 1231
  • [36] Experimental study on continuous spill fire of liquid fuel on porous bed
    Zhai, Xu
    Chen, Peng
    Li, Liyang
    Sun, Ruibang
    Liu, Yang
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (01) : 1937 - 1951
  • [37] Experimental study on the smoke temperature evolution in a polyethylene (PE)-lined compartment on fire
    Junhui Gong
    Di Wang
    Long Shi
    Xuanya Liu
    Ye Chen
    Guomin Zhang
    Journal of Thermal Analysis and Calorimetry, 2020, 140 : 1907 - 1917
  • [38] Experimental study on the smoke temperature evolution in a polyethylene (PE)-lined compartment on fire
    Gong, Junhui
    Wang, Di
    Shi, Long
    Liu, Xuanya
    Chen, Ye
    Zhang, Guomin
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 140 (04) : 1907 - 1917
  • [39] Experimental and numerical study on kerosene pool fire suppression with water mist in a standard confined compartment
    Zheng, LG
    Yu, MG
    Xing, ZF
    Liu, ZC
    Zuo, QL
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1187 - 1192
  • [40] Experimental study of dynamic combustion behavior and heat transfer of heptane pool fire with burning time under thin fuel thickness (2.0 mm-14.0 mm)
    Wang, Chen