In recent years, improved efficiency of pulse tube cryocoolers has been required by some space infrared detectors and special military applications. Based on this, a high efficiency single-stage coaxial pulse tube cryocooler which operates at 60 K is introduced in this paper. The cryocooler is numerically designed using SAGE, and details of the analysis are presented. The performance of the cryocooler at different input powers ranging from 100 W to 200 W is experimentally tested. Experimental results show that this cryocooler typically provides a cooling power of 7.7 W at 60 K with an input power of 200 W, and achieves a relative Carnot efficiency of around 15%. When the cooling power is around 6 W, the cryocooler achieves the best relative Carnot efficiency of around 15.9% at 60 K, which is the highest efficiency ever reported for a coaxial pulse tube cryocooler.
引用
收藏
页码:48 / 50
页数:3
相关论文
共 50 条
  • [21] 18.6 K single-stage high frequency multi-bypass coaxial pulse tube cryocooler
    Chen, Liubiao
    Jin, Hai
    Wang, Junjie
    Zhou, Yuan
    Zhu, Wenxiu
    Zhou, Qiang
    CRYOGENICS, 2013, 54 : 54 - 58
  • [22] A study of performance improvement of the coaxial inertance tube pulse tube cryocooler
    Park, SJ
    Hong, YJ
    Kim, HB
    Kim, YH
    CRYOCOOLERS 13, 2005, : 261 - 266
  • [23] Development of a 2 W at 60 K pulse tube cryocooler for spaceborne operation
    Kotsubo, V
    Olson, JR
    Nast, TC
    CRYOCOOLERS 10, 1999, : 157 - 161
  • [24] CFD simulation of a miniature coaxial Stirling-type pulse tube cryocooler operating at 128 Hz
    Zhao, Yibo
    Dang, Haizheng
    CRYOGENICS, 2016, 73 : 53 - 59
  • [25] Operating characteristics of a three-stage Stirling pulse tube cryocooler operating around 5 K
    Qiu, L. M.
    Cao, Q.
    Zhi, X. Q.
    Han, L.
    Gan, Z. H.
    Yu, Y. B.
    Liu, Y.
    Zhang, X. J.
    Pfotenhauer, J. M.
    CRYOGENICS, 2012, 52 (7-9) : 382 - 388
  • [26] Design and optimization of heat exchanger in coaxial pulse tube cryocooler working above 100 K
    Duan, Yanbo
    Pan, Changzhao
    Wang, Wei
    Li, Laifeng
    Zhou, Yuan
    CRYOGENICS, 2023, 129
  • [27] High efficiency 40 K single-stage Stirling-type pulse tube cryocooler
    Wu, X. L.
    Chen, L. B.
    Pan, C. Z.
    Cui, C.
    Wang, J. J.
    Zhou, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [28] High-capacity 60 K single-stage coaxial pulse tube cryocoolers
    Dang, Haizheng
    CRYOGENICS, 2012, 52 (4-6) : 205 - 211
  • [29] Investigations of a two-stage pulse tube cryocooler operating down to 2.5K
    Shafi, K. A.
    Sajid, N. K. Mohammed
    Kasthurirengan, S.
    Upendra, B.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2010, 224 (C6) : 1255 - 1260
  • [30] A single-stage GM-type pulse tube cryocooler operating at 10.6 K
    Gan, Z. H.
    Dong, W. Q.
    Qiu, L. M.
    Zhang, X. B.
    Sun, H.
    He, Y. L.
    Radebaugh, R.
    CRYOGENICS, 2009, 49 (05) : 198 - 201