A direct filtered back-projection reconstruction method for inverse geometry CT without gridding: a simulation study

被引:2
|
作者
Jiang, Xiao [1 ]
Zhu, Lei [2 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
inverse geometry CT; filtered backprojection; offset source; FOURIER INVERSION; ALGORITHM; SYSTEM;
D O I
10.1117/12.2507356
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inverse geometry computed tomography (IGCT) uses a small detector and a set of widely distributed x-ray sources. Standard filtered backprojection (FBP) reconstruction for a conventional CT geometry cannot be directly used in IGCT, due to data truncation and redundancy of the sinograms acquired by different sources. Current IGCT algorithms use gridding or iterations during reconstruction, leading to degraded spatial resolution or increased computational cost. In this work, we propose a direct FBP reconstruction method for IGCT without gridding. A reconstruction algorithm is first derived for a full-size sinogram acquired by a single source with a known offset distance to the central line passing through the rotational axis and perpendicular to the detector. A weighting scheme is then developed on the projections to remove the data redundancy of different sinograms acquired by different sources. The final reconstruction is obtained as the summation of CT images reconstructed from different sources, in a form of FBP on weighted projections. The performance of the proposed algorithm is evaluated via simulation studies on the Shepp-Logan phantom. Results show that our algorithm substantially improves the image spatial resolution over the gridding method. The spatial resolution increases by 32.08% and 23.26% at 50% and 10% of the modulation transfer function, respectively. Finally, we demonstrate the advantages of volumetric IGCT compared with circular cone-beam CT in a pilot study.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [1] Accelerated Reconstruction for Inverse Geometry CT via Derivative Back-projection Filtration
    Jiang, Xiao
    Huang, Bangyan
    Zhu, Lei
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [2] An adaptive filtered back-projection for photoacoustic image reconstruction
    Huang, He
    Bustamante, Gilbert
    Peterson, Ralph
    Ye, Jing Yong
    MEDICAL PHYSICS, 2015, 42 (05) : 2169 - 2178
  • [3] Generalized filtered back-projection reconstruction in breast tomosynthesis
    Claus, Bernhard E. H.
    Eberhard, Jeffrey W.
    Schmitz, Andrea
    Carson, Paul
    Goodsitt, Mitchell
    Chan, Heang-Ping
    DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 167 - 174
  • [4] Filtered back-projection reconstruction for attenuation proton CT along most likely paths
    Quinones, C. T.
    Letang, J. M.
    Rit, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3258 - 3278
  • [5] Filtered back-projection image reconstruction algorithm for opposite parallel linear CT scanning
    Wu W.
    Quan C.
    Liu F.
    Guangxue Xuebao/Acta Optica Sinica, 2016, 36 (09):
  • [6] An investigation of filter choice for filtered back-projection reconstruction in PET
    Farquhar, TH
    Chatziioannou, A
    Chinn, G
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1133 - 1137
  • [7] Investigation of filter choice for filtered back-projection reconstruction in PET
    Farquhar, T.H.
    Chatziioannou, A.
    Chinn, G.
    Dahlbom, M.
    Hoffman, E.J.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 2): : 1133 - 1137
  • [8] Reconstruction in PET From Filtered Back-Projection to Artificial Intelligence
    Gong, Kuang
    Kim, Kyungsang
    Cui, Jianan
    Wu, Dufan
    Li, Quanzheng
    PET CLINICS, 2021, 16 (04) : 533 - 542
  • [9] An investigation of filter choice for filtered back-projection reconstruction in PET
    Farquhar, TH
    Chatziioannou, A
    Chinn, G
    Dahlbom, M
    Hoffman, EJ
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1042 - 1046
  • [10] A novel denoising method based on Radon transform and filtered back-projection reconstruction algorithm
    Qu, Hong-yan
    Xu, Feng
    Hu, Xiao-fang
    Wang, Luo-bin
    Zhao, Jing
    Zhang, Zhong
    OPTICS AND LASERS IN ENGINEERING, 2012, 50 (04) : 593 - 598