Filtered back-projection reconstruction for attenuation proton CT along most likely paths

被引:14
|
作者
Quinones, C. T. [1 ]
Letang, J. M. [1 ]
Rit, S. [1 ]
机构
[1] Univ Lyon 1, Ctr Leon Berard, CREATIS, CNRS,UMR5220,Inserm,U1206,INSA Lyon, F-69622 Villeurbanne, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
关键词
proton computed tomography; proton CT; filtered back-projection; most likely path; inelastic cross-section; attenuation; MULTIPLE COULOMB SCATTERING; COMPUTED-TOMOGRAPHY; STOPPING-POWER; MONTE-CARLO; RANGE UNCERTAINTIES; SPATIAL-RESOLUTION; CONCEPTUAL DESIGN; RADIOGRAPHY; THERAPY; RADIOTHERAPY;
D O I
10.1088/0031-9155/61/9/3258
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work investigates the attenuation of a proton beam to reconstruct the map of the linear attenuation coefficient of a material which is mainly caused by the inelastic interactions of protons with matter. Attenuation proton computed tomography (pCT) suffers from a poor spatial resolution due to multiple Coulomb scattering (MCS) of protons in matter, similarly to the conventional energy-loss pCT. We therefore adapted a recent filtered back-projection algorithm along the most likely path (MLP) of protons for energy-loss pCT (Rit et al 2013) to attenuation pCT assuming a pCT scanner that can track the position and the direction of protons before and after the scanned object. Monte Carlo simulations of pCT acquisitions of density and spatial resolution phantoms were performed to characterize the new algorithm using Geant4 (via Gate). Attenuation pCT assumes an energy-independent inelastic cross-section, and the impact of the energy dependence of the inelastic crosssection below 100 MeV showed a capping artifact when the residual energy was below 100 MeV behind the object. The statistical limitation has been determined analytically and it was found that the noise in attenuation pCT images is 411 times and 278 times higher than the noise in energy-loss pCT images for the same imaging dose at 200 MeV and 300 MeV, respectively. Comparison of the spatial resolution of attenuation pCT images with a conventional straight-line path binning showed that incorporating the MLP estimates during reconstruction improves the spatial resolution of attenuation pCT. Moreover, regardless of the significant noise in attenuation pCT images, the spatial resolution of attenuation pCT was better than that of conventional energy-loss pCT in some studied situations thanks to the interplay of MCS and attenuation known as the West-Sherwood effect.
引用
收藏
页码:3258 / 3278
页数:21
相关论文
共 50 条
  • [1] Filtered backprojection proton CT reconstruction along most likely paths
    Rit, Simon
    Dedes, George
    Freud, Nicolas
    Sarrut, David
    Letang, Jean Michel
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [2] Space Carving and Filtered Back-Projection as Preconditioners for Proton Computed Tomography Reconstruction
    Schultze, Blake
    Witt, Micah
    Schubert, Keith E.
    Hurley, Robert F.
    Bashkirov, Vladimir
    Schulte, Reinhard W.
    Gomez, Ernesto
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4335 - 4340
  • [3] An adaptive filtered back-projection for photoacoustic image reconstruction
    Huang, He
    Bustamante, Gilbert
    Peterson, Ralph
    Ye, Jing Yong
    [J]. MEDICAL PHYSICS, 2015, 42 (05) : 2169 - 2178
  • [4] Generalized filtered back-projection reconstruction in breast tomosynthesis
    Claus, Bernhard E. H.
    Eberhard, Jeffrey W.
    Schmitz, Andrea
    Carson, Paul
    Goodsitt, Mitchell
    Chan, Heang-Ping
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 167 - 174
  • [5] An investigation of filter choice for filtered back-projection reconstruction in PET
    Farquhar, TH
    Chatziioannou, A
    Chinn, G
    Dahlbom, M
    Hoffman, EJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1133 - 1137
  • [6] Reconstruction in PET From Filtered Back-Projection to Artificial Intelligence
    Gong, Kuang
    Kim, Kyungsang
    Cui, Jianan
    Wu, Dufan
    Li, Quanzheng
    [J]. PET CLINICS, 2021, 16 (04) : 533 - 542
  • [7] An investigation of filter choice for filtered back-projection reconstruction in PET
    Farquhar, TH
    Chatziioannou, A
    Chinn, G
    Dahlbom, M
    Hoffman, EJ
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1042 - 1046
  • [8] Deep Filtered Back Projection for CT Reconstruction
    Tan, Xi
    Liu, Xuan
    Xiang, Kai
    Wang, Jing
    Tan, Shan
    [J]. IEEE ACCESS, 2024, 12 : 20962 - 20972
  • [9] Improvement of wavelet threshold filtered back-projection image reconstruction algorithm
    Ren, Zhong
    Liu, Guodong
    Huang, Zhen
    [J]. INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGE PROCESSING AND PATTERN RECOGNITION, 2014, 9301
  • [10] Reconstruction of grain boundaries in polycrystals by filtered back-projection of diffraction spots
    Poulsen, HF
    Schmidt, S
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2003, 36 : 319 - 325