Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study

被引:2
|
作者
Xu, Wei-Xing [1 ]
Ding, Wei-Guo [1 ]
Xu, Bin [1 ]
Hu, Tian-Hong [1 ]
Sheng, Hong-Feng [1 ]
Zhu, Jia-Fu [1 ]
Zhu, Xiao-Long [1 ]
机构
[1] Tongde Hosp Zhejiang Prov, Dept Orthopaed, 234 Gu Cui Rd, Hangzhou 310012, Peoples R China
关键词
C-arm X-ray fluoroscopy; Insertion point; Facet joint; Pedicle projection; FACET JOINT VIOLATION; INTERBODY FUSION; ADJACENT; INSTRUMENTATION; RATES;
D O I
10.1186/s12891-020-03751-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundWe studied the characteristics and regularity of appropriate insertion points for percutaneous pedicle screw placement in the lumbar spine using C-arm X-ray fluoroscopy. The purpose of this study was to improve the accuracy of percutaneous pedicle screw placement and reduce the incidence of superior-level facet joint violation.MethodsSix normal spinal specimens were included. Three different methods for placing percutaneous pedicle screws in the lumbar spine were applied, including the Roy-Camille method, Magerl method and Weinstein method. The relationships among the insertion point, pedicle projection and proximal facet joint on C-arm X-ray films were studied. The projection morphology of the vertebral pedicle in different segments of the lumbar spine was observed. The relationship between the outer edge of the pedicle projection and the outer edge of the cranial articular process was also studied. The distance between the insertion point and the facet joint (M1), the distance between the insertion point and outer edge of the cranial articular process (M2), and the distance between the insertion point and the projection center of the pedicle (M) were measured.ResultsIn this study, we found that the projection shape of the vertebral pedicle differed across segments of the lumbar spine: the shape for L1-L3 was oval, and that for L4-L5 was round. The radiographic study showed that the outer edge of the cranial articular process was located on the lateral side of the outer edge of the pedicle projection and did not overlap with the pedicle projection. M for the Weinstein group was larger than that for the Roy-Camille group (P< 0.05). M1 for the Weinstein group was larger than that for the Roy-Camille and Magerl groups (P< 0.05). M2 for the Roy-Camille group was negative, M2 for the Magerl group was 0, and M2 for the Weinstein group was positive.ConclusionUnder C-arm X-ray fluoroscopy, we were able to accurately identify the characteristics and regularity of the appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine, which was important for improving the accuracy of percutaneous pedicle screw placement and reducing the incidence of superior-level facet joint violation.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Novel augmentation technique of percutaneous pedicle screw fixation using hydroxyapatite granules in the osteoporotic lumbar spine: a cadaveric biomechanical analysis
    Kanno, Haruo
    Aizawa, Toshimi
    Hashimoto, Ko
    Itoi, Eiji
    [J]. EUROPEAN SPINE JOURNAL, 2021, 30 (01) : 71 - 78
  • [42] Clinical Assessment of Percutaneous Lumbar Pedicle Screw Placement Using the O-Arm Multidimensional Surgical Imaging System
    Houten, John K.
    Nasser, Rani
    Baxi, Nrupen
    [J]. NEUROSURGERY, 2012, 70 (04) : 990 - 995
  • [43] The accuracy of pedicle screw placement in the thoracic spine using the "funnel technique" - Part 1. A cadaveric study
    Yingsakmonkol, W
    Karaikovic, T
    Gaines, RW
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (06): : 445 - 449
  • [44] Accuracy of Percutaneous Pedicle Screw Placement after Single-Position versus Dual-Position Insertion for Lateral Interbody Fusion and Pedicle Screw Fixation Using Fluoroscopy
    Hiyama, Akihiko
    Katoh, Hiroyuki
    Sakai, Daisuke
    Sato, Masato
    Tanaka, Masahiro
    Watanabe, Masahiko
    [J]. ASIAN SPINE JOURNAL, 2022, 16 (01) : 20 - 27
  • [45] Screw Insertion Time, Fluoroscopy Time, and Operation Time for Robotic-Assisted Lumbar Pedicle Screw Placement Compared With Freehand Technique
    Torii, Yoshiaki
    Ueno, Jun
    Umehara, Tasuku
    Iinuma, Masahiro
    Yoshida, Atsuhiro
    Tomochika, Ken
    Niki, Hisateru
    Akazawa, Tsutomu
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (05)
  • [46] Sensorless Based Haptic Feedback Integration In Robot-assisted Pedicle Screw Insertion For Lumbar Spine Surgery: A preliminary cadaveric study
    Nakdhamabhorn, Sakol
    Pillai, Branesh M.
    Chotivichit, Areesak
    Suthakorn, Jackrit
    [J]. COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2024, 24 : 420 - 433
  • [47] Reduction in radiation during percutaneous lumbar pedicle screw placement using a new device
    Zhang, Lei
    Zhou, Xu
    Cai, Xiaobing
    Zhang, Hailong
    Fu, Qingsong
    He, Shisheng
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (3-4) : 173 - 178
  • [48] Treatment of Lumbar Intervertebral Disc Herniation Using C-Arm Fluoroscopy Guided Target Percutaneous Laser Disc Decompression
    Zhao, Xu-Li
    Fu, Zhi-Jian
    Xu, Yong-Guang
    Zhao, Xue-Jun
    Song, Wen-Ge
    Zheng, Hong
    [J]. PHOTOMEDICINE AND LASER SURGERY, 2012, 30 (02) : 92 - 95
  • [49] The combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note
    Hiyama, Akihiko
    Ukai, Taku
    Nomura, Satoshi
    Watanabe, Masahiko
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [50] The combination of intraoperative CT navigation and C-arm fluoroscopy for INFIX and percutaneous TITS screw placement in the treatment of pelvic ring injury: technical note
    Akihiko Hiyama
    Taku Ukai
    Satoshi Nomura
    Masahiko Watanabe
    [J]. Journal of Orthopaedic Surgery and Research, 17