Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study

被引:2
|
作者
Xu, Wei-Xing [1 ]
Ding, Wei-Guo [1 ]
Xu, Bin [1 ]
Hu, Tian-Hong [1 ]
Sheng, Hong-Feng [1 ]
Zhu, Jia-Fu [1 ]
Zhu, Xiao-Long [1 ]
机构
[1] Tongde Hosp Zhejiang Prov, Dept Orthopaed, 234 Gu Cui Rd, Hangzhou 310012, Peoples R China
关键词
C-arm X-ray fluoroscopy; Insertion point; Facet joint; Pedicle projection; FACET JOINT VIOLATION; INTERBODY FUSION; ADJACENT; INSTRUMENTATION; RATES;
D O I
10.1186/s12891-020-03751-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundWe studied the characteristics and regularity of appropriate insertion points for percutaneous pedicle screw placement in the lumbar spine using C-arm X-ray fluoroscopy. The purpose of this study was to improve the accuracy of percutaneous pedicle screw placement and reduce the incidence of superior-level facet joint violation.MethodsSix normal spinal specimens were included. Three different methods for placing percutaneous pedicle screws in the lumbar spine were applied, including the Roy-Camille method, Magerl method and Weinstein method. The relationships among the insertion point, pedicle projection and proximal facet joint on C-arm X-ray films were studied. The projection morphology of the vertebral pedicle in different segments of the lumbar spine was observed. The relationship between the outer edge of the pedicle projection and the outer edge of the cranial articular process was also studied. The distance between the insertion point and the facet joint (M1), the distance between the insertion point and outer edge of the cranial articular process (M2), and the distance between the insertion point and the projection center of the pedicle (M) were measured.ResultsIn this study, we found that the projection shape of the vertebral pedicle differed across segments of the lumbar spine: the shape for L1-L3 was oval, and that for L4-L5 was round. The radiographic study showed that the outer edge of the cranial articular process was located on the lateral side of the outer edge of the pedicle projection and did not overlap with the pedicle projection. M for the Weinstein group was larger than that for the Roy-Camille group (P< 0.05). M1 for the Weinstein group was larger than that for the Roy-Camille and Magerl groups (P< 0.05). M2 for the Roy-Camille group was negative, M2 for the Magerl group was 0, and M2 for the Weinstein group was positive.ConclusionUnder C-arm X-ray fluoroscopy, we were able to accurately identify the characteristics and regularity of the appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine, which was important for improving the accuracy of percutaneous pedicle screw placement and reducing the incidence of superior-level facet joint violation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Wei-Xing Xu
    Wei-Guo Ding
    Bin Xu
    Tian-Hong Hu
    Hong-Feng Sheng
    Jia-Fu Zhu
    Xiao-Long Zhu
    [J]. BMC Musculoskeletal Disorders, 21
  • [2] Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy
    Schizas, Constantin
    Thein, Eric
    Kwiatkowski, Barbara
    Kulik, Gerit
    [J]. ACTA ORTHOPAEDICA BELGICA, 2012, 78 (02): : 240 - 245
  • [3] O-Arm Assisted Cervicothoracic Spine Pedicle Screw Placement Accuracy Is Higher Than C-Arm Fluoroscopy
    Inoue, Tomohisa
    Wada, Keiji
    Tominaga, Ayako
    Tamaki, Ryo
    Hirota, Tomoya
    Okazaki, Ken
    [J]. WORLD NEUROSURGERY, 2022, 158 : E996 - E1001
  • [4] Assessment of Lumbar Spine Instability Using C-Arm Fluoroscopy
    Temes, Bill
    Karas, Steve
    Manwill, James
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2016, 46 (09): : 810 - 810
  • [5] Percutaneous Pedicle Screw and Rod Insertion for Fracture of the Lumbar Spine
    Sahoo, Prafulla Kumar
    [J]. INDIAN JOURNAL OF NEUROTRAUMA, 2005, 2 (02): : 143 - 148
  • [6] Percutaneous Pedicle Screw Placement in the Lumbar Spine A Comparison Study Between the Novel Guidance System and the Conventional Fluoroscopy Method
    Gu, Guangfei
    Zhang, Hailong
    He, Shisheng
    Cai, Xiaobing
    Gu, Xin
    Jia, Jianbo
    Fu, Qingsong
    Zhou, Xu
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (09): : E522 - E527
  • [7] C-arm assessment of cervical pedicle screw - Screw coaxial fluoroscopy and oblique view
    Cha, Seung Heon
    Kim, Choongrak
    Choi, Byung Kwan
    Kim, Hak Jin
    Baek, Sun Yong
    [J]. SPINE, 2007, 32 (16) : 1721 - 1727
  • [8] Use of a Novel Computerized Drill for Pedicle Screw Insertion in the Thoracic and Lumbar Spine: A Cadaveric Study
    Shepard, Nicholas
    Hien Pham
    Natarajan, Vivek
    Errico, Thomas
    Rieger, Mark
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2019, 13 (04): : 329 - 335
  • [9] Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine
    Yoo, JU
    Ghanayem, A
    Petersilge, C
    Lewin, J
    [J]. SPINE, 1997, 22 (22) : 2668 - 2671
  • [10] Pediatric Lumbar Pedicle Screw Placement Using Navigation Templates A Cadaveric Study
    Wang, Xing
    Shi, Jun
    Zhang, Shojie
    Zhang, Zhifeng
    Li, Xiaohe
    Li, Zhijun
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (04) : 468 - 473