Control strategy of doubly-fed induction generator during the grid voltage swell

被引:5
|
作者
Zou Le [1 ]
Wu Xueguang [2 ]
Kou Longze [3 ]
Liu Dong [4 ]
Li Fangyuan [3 ]
Han Mingxiao [1 ]
机构
[1] North China Elect Power Univ, Beijing, Peoples R China
[2] Global Energy Interconnect Res Inst, Beijing, Peoples R China
[3] Beijing Key Lab DC Grid Technol & Simulat, Beijing, Peoples R China
[4] State Key Lab Adv Power Transmiss Technol, Beijing, Peoples R China
来源
关键词
power grids; choppers (circuits); reactive power; asynchronous generators; power generation control; wind turbines; rotors; wind power plants; doubly-fed induction generator; grid voltage swell; effective control strategy; grid-side converter; rotor current suppression; wind turbine; dynamic reactive power support; power electronic devices; high voltage ride; wind power integration; control scheme;
D O I
10.1049/joe.2018.8834
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study firstly derives the relationship between the grid voltage and the rotor current of doubly-fed induction generator (DFIG) during the grid voltage swell. Then, an effective control strategy aiming to restrain rotor over-current is proposed and the control strategy of the grid-side converter is also improved. The proposed rotor current suppression and grid voltage suppression method, cooperating with the DC chopper, can not only solve the problem of short circuit of the rotor side converter resulting from the frequent switching of crowbar device, but also maximally improve the capability of wind turbine in dynamic reactive power support without adding any other power electronic devices. With the help of this control strategy, the wind turbine could maintain its normal operation even during the fault and the high voltage ride through of wind turbine can be achieved. As a result, the stability of the wind power integration is significantly improved. Finally, the simulations and analysis in the power systems computer aided design (PSCAD)/electromagnetic transients including DC (EMTDC) verify the effectiveness and feasibility of the proposed control scheme.
引用
收藏
页码:1807 / 1811
页数:5
相关论文
共 50 条
  • [21] Variable damping based control strategy of doubly fed induction generator based wind turbines under grid voltage swell
    [J]. Xie, Z. (ppsd2003xie@sina.com), 1600, Automation of Electric Power Systems Press (36):
  • [22] Control method of a doubly-fed induction generator with automatic grid synchronization
    Park, Jungwoo
    Lee, Kiwook
    Kim, Dongwook
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1093 - +
  • [23] Predictive control of a doubly-fed induction generator connected to an isolated grid
    Patin, Nicolas
    Naouar, Wissem
    Monmasson, Eric
    Louis, Jean-Paul
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 3129 - +
  • [24] Intelligent Control of Grid Connected Unified Doubly-Fed Induction Generator
    Singh, Bharat
    Kyriakides, Elias
    Singh, Sri Niwas
    [J]. IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [25] Virtual Synchronous Control Strategy for Doubly-Fed Induction Generator under Asymmetrical Grid Faults
    Cheng, Xuekun
    Sun, Xudong
    Chai, Jianyun
    Zhao, Yangyang
    [J]. 2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,
  • [26] Decoupling Control Strategy for Doubly-fed Induction Generator the Rotor Cross-Coupling Voltage
    Zhou Yuanshen
    [J]. PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 5, 2008, : 174 - 179
  • [27] Direct voltage control for grid synchronization of doubly-fed induction generators
    Wong, K. C.
    Ho, S. L.
    Cheng, K. W. E.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2008, 36 (09) : 960 - 976
  • [28] VSCF doubly-fed induction generator control strategy and simulation research
    Wang, Rongxi
    Lin, Fei
    Hao, Ruixiang
    You, Xiaojie
    Zheng, Trillion Q.
    [J]. ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 2045 - 2050
  • [29] An improved control strategy for doubly fed induction wind generators under unbalanced grid voltage swell
    School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, Anhui Province, China
    [J]. Zhongguo Dianji Gongcheng Xuebao, 2013, 15 (109-118):
  • [30] Dynamic performance of doubly-fed induction generator stator flux during consecutive grid voltage variations
    Zhu, Rongwu
    Chen, Zhe
    Wu, Xiaojie
    [J]. IET RENEWABLE POWER GENERATION, 2015, 9 (07) : 720 - 728