REDUCTION OF THE STRUCTURAL NOISE OF AN OUTDOOR AIR CONDITIONER IN A RESIDENTIAL BUILDING

被引:0
|
作者
Dombi, Istvan [1 ]
Bite, Maria [1 ]
Bite, Pal [1 ]
机构
[1] Vibrocomp Ltd, Bozokvar Utca 12, H-1118 Budapest, Hungary
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The outdoor units of the air conditioner of a cell phone amplifier station were mounted on the roof (attic) ceiling of a residential brick building. The residents that live in the apartment under the outdoor unit complain about high noise levels. By a local study, carried out in the building, we measured the noise generated in the residential room, the structural-noise component of the immission noise and the way of propagation of that noise. The machine foundation of the outdoor unit had insufficient vibration and structural noise absorption. This insufficient nature of the machine foundation was the cause of the high noise. We designed a modified machine foundation on the ceiling, which provided sufficient protection against structural noise. This modified foundation achieved a noise reduction of Delta L-Lambda = -10dB in the residential room.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Residential air-conditioner usage in China and efficiency standardization
    Wu, Jianghong
    Liu, Chaopeng
    Li, Hongqi
    Ouyang, Dong
    Cheng, Jianhong
    Wang, Yuanxia
    You, Shaofang
    [J]. ENERGY, 2017, 119 : 1036 - 1046
  • [42] Finite element analysis of dynamic stress of the outdoor unit of air conditioner
    Yang, Rong
    Li, Shiyun
    Zhou, Shaoping
    Guo, Jun
    Zhang, Lanzhu
    Hui, Hu
    [J]. EVALUATION, INSPECTION AND MONITORING OF STRUCTURAL INTEGRITY, 2008, : 153 - 157
  • [43] Numerical Simulation for Thermal Distribution of Air-conditioner Outdoor Units
    Tong, Li-Ge
    Zhang, Zhen
    Wang, Li
    Yin, Shao-Wu
    Yu, Jiangfeng
    Liu, Chun
    [J]. JOURNAL OF THERMAL SCIENCE, 2012, 21 (03) : 269 - 275
  • [44] Numerical Simulation for Thermal Distribution of Air-conditioner Outdoor Units
    Li-Ge Tong1
    [J]. Journal of Thermal Science, 2012, 21 (03) : 269 - 275
  • [45] Numerical simulation for thermal distribution of air-conditioner outdoor units
    Li-Ge Tong
    Zhen Zhang
    Li Wang
    Shao-Wu Yin
    Jiangfeng Yu
    Chun Liu
    [J]. Journal of Thermal Science, 2012, 21 : 269 - 275
  • [46] Effect of the Muffler on Fluctuation Noise in the Air-conditioner
    Zhang, Liping
    [J]. 2015 2ND INTERNATIONAL CONFERENCE ON INTELLIGENT MATERIALS AND MECHATRONICS (IMM 2015), 2015, : 49 - 52
  • [47] Development of Air Conditioner Robot Prototype That Follows Humans in Outdoor Applications
    Chaari, Mohamed Zied
    Abdelfatah, Mohamed
    Loreno, Christopher
    Al-Rahimi, Rashid
    [J]. ELECTRONICS, 2021, 10 (14)
  • [48] User Demand-Oriented Evaluation of Outdoor Unit of Air Conditioner
    Liu, Weilin
    Xu, Chunfeng
    [J]. DIGITAL HUMAN MODELING AND APPLICATIONS IN HEALTH, SAFETY, ERGONOMICS AND RISK MANAGEMENT, PT I, DHM 2024, 2024, 14709 : 295 - 307
  • [49] Study on Flow Analysis and Noise Reduction of Centrifugal Fan for Air Conditioner Based on the Modification of Volute Tongue
    Wang, Meng-Hao
    Wu, Li-Ming
    Liu, Xiao-Min
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (01): : 147 - 153
  • [50] A Study on the Reduction of the Aerodynamic Drag and Noise Generated By the Roof Air Conditioner of High-Speed Trains
    Liu, Jiali
    Yu, Mengge
    Chen, Dawei
    Yang, Zhigang
    [J]. FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2020, 16 (01): : 21 - 30