Validation of the summary ROC for diagnostic test meta-analysis: A Monte Carlo simulation

被引:25
|
作者
Mitchell, MD [1 ]
机构
[1] ECRI, Technol Assessment Grp, Plymouth Meeting, PA 19462 USA
关键词
data analysis; receiver operating characteristic curve (ROC); meta-analysis;
D O I
10.1016/S1076-6332(03)80784-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The author performed this study to test a technique for validating the logit regression method for summary receiver operating characteristic (ROC) meta-analysis, perform initial validation studies, and identify areas for further investigation. Materials and Methods. Monte Carlo simulation was performed by using a custom macro program for a personal computer spreadsheet. The program creates simulated data sets based on user-specified parameters, performs a meta-analysis on the data sets, and logs the results so the accuracy and variability of the method can be measured. The program can also be used to measure the effects of changes in study design and meta-analysis parameters. Results. For the base case of a small meta-analysis (10 studies) of small trials (mean, 50 patients), the meta-analysis results closely matched the input sensitivity and specificity when they were less than 80%. Systematic errors, if any, were small. At sensitivities and specificities greater than 80%, the true sensitivity or specificity was underestimated by up to 2% in the meta-analysis. Confidence intervals calculated with the summary ROC curve were reasonably conservative, although they too fell below the true results when sensitivity or specificity was greater than 80%. The underestimation was eliminated when the simulation was repeated for a much larger trial (mean, 1,000 cases per study)-even with a sensitivity and specificity of 98%. Conclusion. The Littenberg-Moses method for summary ROC meta-analysis is effective for obtaining an accurate summary estimate of diagnostic test performance, although the continuity correction introduces a small downward bias in the meta-analysis of small trials.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [21] Is EUS-guided FNA of the pancreas superior to other modalities? A meta-analysis with Monte Carlo simulation
    Gottlieb, K
    Gress, F
    GASTROINTESTINAL ENDOSCOPY, 1999, 49 (04) : AB90 - AB90
  • [22] A SIMEX approach for meta-analysis of diagnostic accuracy studies with attention to ROC curves
    Guolo, Annamaria
    Cabrera, Tania Erika Pesantez
    INTERNATIONAL JOURNAL OF BIOSTATISTICS, 2023, 19 (02): : 455 - 471
  • [23] Meta-analysis of Diagnostic Accuracy and ROC Curves with Covariate Adjusted Semiparametric Mixtures
    Philipp Doebler
    Heinz Holling
    Psychometrika, 2015, 80 : 1084 - 1104
  • [24] Meta-analysis of Diagnostic Accuracy and ROC Curves with Covariate Adjusted Semiparametric Mixtures
    Doebler, Philipp
    Holling, Heinz
    PSYCHOMETRIKA, 2015, 80 (04) : 1084 - 1104
  • [25] Monte Carlo simulation of a mammographic test phantom
    Hunt, RA
    Dance, DR
    Pachoud, M
    Carlsson, GA
    Sandborg, M
    Ullman, G
    Verdun, FR
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 432 - 435
  • [26] A Monte Carlo Analysis of Alternative Meta-Analysis Estimators in the Presence of Publication Bias
    Reed, W. Robert
    ECONOMICS-THE OPEN ACCESS OPEN-ASSESSMENT E-JOURNAL, 2015, 9
  • [27] Accuracy of voided urine cytology in the diagnosis of bladder cancer: A meta-analysis with summary ROC curve analysis
    Poulakis, V
    Witzsch, U
    Becht, E
    JOURNAL OF UROLOGY, 2003, 169 (04): : 225 - 225
  • [28] Meta-analysis of diagnostic studies: A comparison of random intercept, normal-normal, and binomial-normal bivariate summary ROC approaches
    Hamza, Taye H.
    Reitsma, Johannes B.
    Stijnen, Theo
    MEDICAL DECISION MAKING, 2008, 28 (05) : 639 - 649
  • [29] Meta-MUMS DTA: Implementation, validation, and application of diagnostic test accuracy software for meta-analysis in radiology
    Sokouti, Massoud
    Sadeghi, Ramin
    Pashazadeh, Saeid
    Eslami, Saeid
    Sokouti, Mohsen
    Ghojazadeh, Morteza
    Sokouti, Babak
    CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH, 2021, 9 : 310 - 325
  • [30] VALIDATION OF A BEAMNRC MONTE CARLO SIMULATION OF A BROAD BEAM DIAGNOSTIC X-RAY UNIT
    Worrall, Mark
    Sutton, David G.
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 440 - 451