Health Economic Evaluation of an Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Coronary Stent Compared to a Thin, Durable-Polymer Everolimus-Eluting Stent

被引:4
|
作者
Mattke, Soeren [1 ]
Hanson, Mark [1 ]
Dallmann, Anissa C. [1 ]
Bentele, Marc [2 ]
机构
[1] Benecit Res, 63 Clinton Pl, Newton, MA 02459 USA
[2] BIOTRONIK, Bulach, Switzerland
关键词
Drug-eluting stem; Peri-procedural myocardial infarction; Health economics; Simulation; PERIPROCEDURAL MYOCARDIAL-INFARCTION; PROGNOSTIC VALUE; ARTERY-DISEASE; BIOFLOW V; INTERVENTION; DEFINITIONS; MORTALITY; IMPACT; REVASCULARIZATION; FREQUENCY;
D O I
10.1016/j.carrev.2018.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The study estimated the health economic impact of a latest generation coronary stent with ultrathin struts and bioresorbable polymer coating. Background: The recent BIOFLOW V trial, an international FDA approval trial (ClinicalTrials.gov: NCT02389946), has shown that an ultrathin, bioresorbable polymer sirolimus-eluting stent had a significantly lower rate of target lesion failure and target vessel-related myocardial infarction than a thin, durable polymer everolimus-eluting stent at 12 months, driven by a lower rate of peri-procedural myocardial infarction (ppMI). Methods: We used a Markov model to project mortality and cost outcomes of that lower ppMI rate from a U.S. health system perspective over a 12-month horizon. Model parameters were derived from BIOFLOW V trial data, a systematic literature review and expert interviews. Results: Use of the bioresorbable polymer sirolimus-eluting stent compared to durable polymer everolimuseluting stent is associated with net reductions in medical cost of $124 (Interquartile Range (IQR) $97-154) per patient in 2018 US$, of which $115 (IQR $76-124) accrues to the initial admission and $10 (IQR $7-72) to cost of follow-up. The lower rate of ppMI translates into a gain of 0.000017 (IQR 0.000011-0.000022) quality-adjusted life-years (QALY) per patient. Conclusions: Lower ppMI rates of bioresorbable polymer sirolimus-eluting stent translate into reductions in direct medical cost, while improving patient outcomes. Most of the cost reduction is attributed to the initial admission with moderate savings up to 12 months post-discharge. (C) 2018 The Author(s). Published by Elsevier Inc.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 50 条
  • [1] HEALTH ECONOMIC EVALUATION OF AN ULTRATHIN, BIORESORBABLE POLYMER SIROLIMUS-ELUTING CORONARY STENT COMPARED TO A THIN, DURABLE POLYMER EVEROLIMUS-ELUTING STENT
    Mattke, S.
    Hanson, M.
    Dallmann, A.
    Bentele, M.
    VALUE IN HEALTH, 2018, 21 : S245 - S245
  • [2] Health Economic Evaluation of the Two-Year Results After Implantation of an Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Coronary Stent Compared to a Thin, Durable-Polymer Everolimus-Eluting Stent
    Mattke, Soeren
    Hanson, Mark
    Dallmann, Anissa
    Bentele, Marc
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S20 - S20
  • [3] Ultrathin, Biodegradable-Polymer Sirolimus-Eluting Stent vs Thin, Durable-Polymer Everolimus-Eluting Stent
    Nakamura, Masato
    Kadota, Kazushige
    Nakagawa, Yoshihisa
    Tanabe, Kengo
    Ito, Yoshiaki
    Amano, Tetsuya
    Maekawa, Yuichiro
    Takahashi, Akihiko
    Shiode, Nobuo
    Otsuka, Yoritaka
    Kawasaki, Tomohiro
    Hikichi, Yutaka
    Shite, Junya
    Kozuma, Ken
    Iijima, Raisuke
    Murakami, Yoshitaka
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (13) : 1324 - 1334
  • [4] TWO-YEAR RESULTS AFTER IMPLANTATION OF AN ULTRATHIN, BIORESORBABLE POLYMER SIROLIMUS-ELUTING CORONARY STENT COMPARED TO A THIN, DURABLE POLYMER EVEROLIMUS-ELUTING STENT: HEALTH ECONOMIC EVALUATION
    Mattke, Soeren
    Hanson, Mark
    Dallmann, Anissa C.
    Bentele, Marc
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1152 - 1152
  • [5] Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent Sequential Optical Coherence Tomography Study
    Ogura, Kunihiro
    Tsujita, Hiroaki
    Oishi, Yosuke
    Matsumoto, Hidenari
    Matsukawa, Naoki
    Sakai, Rikuo
    Arai, Taito
    Sato, Shunya
    Tanaka, Hideaki
    Masaki, Ryota
    Arai, Ken
    Nomura, Kosuke
    Kosaki, Ryota
    Sakai, Koshiro
    Sekimoto, Teruo
    Kondo, Seita
    Tsukamoto, Shigeto
    Mori, Hiroyoshi
    Yamamoto, Myong Hwa
    Wakabayashi, Kohei
    Suzuki, Hiroshi
    Ochiai, Masahiko
    Shinke, Toshiro
    INTERNATIONAL HEART JOURNAL, 2021, 62 (03) : 510 - 519
  • [6] Comparison of Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stents and Thin, Durable-Polymer Everolimus-Eluting Stents in Calcified or Small Vessel Lesions
    Dan, Kazuhiro
    Garcia-Garcia, Hector M.
    Kolm, Paul
    Windecker, Stephan
    Saito, Shigeru
    Kandzari, David E.
    Waksman, Ron
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (09) : E009189
  • [7] Early vascular healing following bioresorbable-polymer sirolimus-eluting stent implantation in comparison with durable-polymer everolimus-eluting stent: sequential optical coherence tomography study
    Ogura, K.
    Tsujita, H.
    Arai, T.
    Sakai, R.
    Tanaka, H.
    Masaki, R.
    Oishi, Y.
    Nomura, K.
    Arai, K.
    Sekimoto, T.
    Kondo, S.
    Tsukamoto, S.
    Mori, H.
    Matsumoto, H.
    Shinke, T.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1391 - 1391
  • [8] Efficacy and Safety of Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin, Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization of Patients With Diabetes Mellitus
    Waksman, Ron
    Shlofmitz, Evan
    Windecker, Stephan
    Koolen, Jacques J.
    Saito, Shigeru
    Kandzari, David
    Kolm, Paul
    Lipinski, Michael J.
    Torguson, Rebecca
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (07): : 1020 - 1026
  • [9] Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents
    Kandzari, David E.
    Koolen, Jacques J.
    Doros, Gheorghe
    Massaro, Joseph J.
    Garcia-Garcia, Hector M.
    Bennett, Johan
    Roguin, Ariel
    Gharib, Elie G.
    Cutlip, Donald E.
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (25) : 3287 - 3297
  • [10] Unselected use of ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for coronary revascularization
    Yamaji, Kyohei
    Zanchin, Thomas
    Zanchin, Christian
    Stortecky, Stefan
    Pilgrim, Thomas
    Heg, Dik
    Windecker, Stephan
    Raber, Lorenz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B265 - B266