IR thermography applies to the detection of solar panel

被引:4
|
作者
Jose Suarez-Dominguez, Francisco [1 ]
Belen Prendes-Gero, Maria [1 ]
Martin-Rodriguez, Angel [1 ]
Higuera-Garrido, Alberto [1 ]
机构
[1] Univ Oviedo, Dept Construcc & Ingn Fabricac, Escuela Politecn Mieres, C Gonzalo Gutierrez Quiros S-N, Mieres 33600, Spain
来源
REVISTA DE LA CONSTRUCCION | 2015年 / 14卷 / 03期
关键词
infrared thermography; photovoltaic panels; defects detection; defects monitoring; preventive maintenance;
D O I
10.4067/S0718-915X2015000300001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Solar panels with photovoltaic cells that generate solar power for inclusion in the electricity grid have been installed in the south-facing wall of the Science and Technology Building in the University of Oviedo (Spain) in order to generate clean energy. We describe the application of infrared thermography to the monitoring and detection of defects in the solar panels, based on measurements made in situ between January and May 2011. The results show temperature differences in the panels attributable to panel defects, poor panel functioning or defects in panel assembly and arrangement.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 50 条
  • [21] Degradation detection as a result of ageing organic solar cells by thermography
    Stoynova, Anna
    Dobrikov, Georgi
    Zhivkov, Ivajlo
    Bonev, Borislav
    2016 6TH ELECTRONIC SYSTEM-INTEGRATION TECHNOLOGY CONFERENCE (ESTC), 2016,
  • [22] Leather characterisation by IR Thermography
    Bison, PG
    Grinzato, E
    Marinetti, S
    THERMOSENSE XXVII, 2005, 5782 : 359 - 370
  • [23] Thermography for honeycomb panel inspection
    Thompson, JG
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 1271 - 1274
  • [24] New association for ir thermography
    不详
    BRITISH CORROSION JOURNAL, 1997, 32 (01): : 2 - 2
  • [25] Solar-panel detection goes global
    Kaack, Lynn H.
    NATURE, 2021, 598 (7882) : 567 - 568
  • [26] Defect detection of solar panel using CNN
    Choi K.-H.
    Ha J.-E.
    Journal of Institute of Control, Robotics and Systems, 2020, 26 (12) : 1093 - 1098
  • [27] Analyzing probability of detection as a function of defect size and depth in pulsed IR thermography
    Moskovchenko, Alexey
    Svantner, Michal
    Vavilov, Vladimir
    Chulkov, Arsenii
    NDT & E INTERNATIONAL, 2022, 130
  • [28] Detection of Degradation Effects in Field-Aged c-Si Solar Cells through IR Thermography and Digital Image Processing
    Kaplani, E.
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2012, 2012
  • [29] Nondestructive Corrosion Detection in RC Through Integrated Heat Induction and IR Thermography
    Baek, Seunghoon
    Xue, William
    Feng, Maria Q.
    Kwon, Seungjun
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2012, 31 (02) : 181 - 190
  • [30] IR THERMOGRAPHY IN MOISTURE AND EARTHQUAKE DAMAGE DETECTION PERFORMED IN THE ZICA MONASTERY, SERBIA
    Ristic, Slavica
    Polic-Radovanovic, Suzana
    INTERNATIONAL JOURNAL OF CONSERVATION SCIENCE, 2013, 4 (04) : 387 - 396