Thermodynamic Evaluation of LiCl-H2O and LiBr-H2O Absorption Refrigeration Systems Based on a Novel Model and Algorithm

被引:33
|
作者
Ren, Jie [1 ]
Qian, Zuoqin [1 ]
Yao, Zhimin [1 ,2 ]
Gan, Nianzhong [1 ]
Zhang, Yujia [1 ]
机构
[1] Wuhan Univ Technol, Sch Energy & Power Engn, Wuhan 430063, Hubei, Peoples R China
[2] Univ Technol Sydney, Fac Engn & Informat Technol, Sydney, NSW 2007, Australia
基金
中国国家自然科学基金;
关键词
absorption refrigeration system; thermodynamic analysis; calculation model; LiCl-H2O; LiBr-H2O; off-design behaviors; DYNAMIC SIMULATION-MODEL; EXPERIMENTAL VALIDATION; PERFORMANCE EVALUATION; CHILLER PERFORMANCE; EXERGY ANALYSIS; WATER; LITHIUM; OPTIMIZATION; EQUILIBRIUM; FORMULATION;
D O I
10.3390/en12153037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An absorption refrigeration system (ARS) is an alternative to the conventional mechanical compression system for cold production. This study developed a novel calculation model using the Matlab language for the thermodynamic analysis of ARS. It was found to be reliable in LiCl-H2O and LiBr-H2O ARS simulations and the parametric study was performed in detail. Moreover, two 50 kW water-cooled single effect absorption chillers were simply designed to analyze their off-design behaviors. The results indicate that LiCl-H2O ARS had a higher coefficient of performance (COP) and exergetic efficiency, particularly in the lower generator or higher condenser temperature conditions, but it operated more restrictively due to crystallization. The off-design analyses revealed that the preponderant performance of LiCl-H2O ARS was mainly due to its better solution properties because the temperature of each component was almost the same for both chillers in the operation. The optimum inlet temperature of hot water for LiCl-H2O (83 degrees C) was lower than that of LiBr-H2O (98 degrees C). The cooling water inlet temperature should be controlled within 41 degrees C, otherwise the performances are discounted heavily. The COP and cooling capacity could be improved by increasing the temperature of hot water or chilled water properly, contrary to the exergetic efficiency.
引用
收藏
页数:28
相关论文
共 50 条
  • [21] The effect of additives on condensation evaporation and absorption processes in LiBr-H2O refrigeration system
    Pise, AT
    Devotta, S
    Kant, K
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 513 - 517
  • [22] Development of an absorber for small-size LiBr-H2O absorption refrigeration machines
    Mosa, M
    Zhu, YQ
    Yattara, A
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 416 - 419
  • [23] Analysis on the parameters for LiBr-H2O absorption-ejector hybrid refrigeration system
    Wang, Yanfeng
    Gu, Zhaolin
    Feng, Shiyu
    Li, Yun
    Feng, Xiao
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 1999, 33 (08): : 69 - 73
  • [24] EXERGY ANALYSIS OF A LiBr-H2O VAPOR ABSORPTION REFRIGERATION PLANT: A CASE STUDY
    Anand, Sanjeev
    Gupta, Ankush
    Tyagi, Sudhir Kumar
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (02)
  • [25] A MATHEMATICAL MODEL AND EXPERIMENTS FOR THE LIBR-H2O ABSORPTION HEAT PUMP
    Sun, Jian
    Fu, Lin
    Zhang, Shigang
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2010, VOL 5, PTS A AND B, 2012, : 189 - 195
  • [26] A GEP model for energy and exergy analysis of LiCl-H2O absorption cooling systems
    Sahin, Arzu Sencan
    Kovaci, Tugba
    Dikmen, Erkan
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, 43 (17) : 2099 - 2108
  • [27] Performance of double effect H2O-LiCl absorption refrigeration systems and comparison with H2O-LiBr systems, Part 2: Exergy analysis
    Konwar, D.
    Gogoi, T. K.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 171 - 183
  • [28] Exergy Based Analysis of LiCl-H2O Absorption Cooling System
    Patel, Jatin
    Pandya, Bhargav
    Mudgal, Anurag
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 261 - 269
  • [29] Improved thermodynamic property fields of LiBr-H2O solution
    Chua, HT
    Toh, HK
    Malek, A
    Ng, KC
    Srinivasan, K
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (06): : 412 - 429
  • [30] Theoretical analysis of LiBr/H2O absorption refrigeration systems
    Arora, Akhilesh
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (15) : 1321 - 1340