Comparison of Tc-99m MDP, Tc-99m HSA and Tc-99m HIG uptake in rheumatoid arthritis and its variants

被引:10
|
作者
Sahin, M [1 ]
Bernay, I
Basoglu, T
Canturk, F
机构
[1] Ondokuz Mayis Univ, Fac Med, Dept Nucl Med, TR-55139 Kurupelit, Turkey
[2] Ondokuz Mayis Univ, Fac Med, Dept Phys Therapy & Rehabil, TR-55139 Kurupelit, Turkey
关键词
arthritis; technetium-99m polyclonal immunoglobulin G; technetium-99m albumin; technetium-99m methylene diphosphonate;
D O I
10.1007/BF03164932
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tc-99m polyclonal immunoglobulin-a has been shown to be a successful agent in the depiction of active inflammation in rheumatoid arthritis (RA). The objective of this study was to compare the uptake behaviors of Tc-99m HIG and Tc-99m MDP in RA and variants of rheumatoid arthritis (VRA). Seventeen patients with RA and 8 patients with VRA presenting with active inflammation were included in this study. Ten subjects with well-diagnosed degenerative joint disease constituted the control group. All joints in patients were also imaged with Tc-99m HSA to evaluate the vascularization status of the joints. Tc-99m HIG and HSA scans were obtained at 2, 4 and 24 hours after the injection of 555 MBq Tc-99m HIG and 296 MBq Tc-99m HSA. Conventional bone scans were performed 4 hours after the injection of 740 MBq Tc-99m MDP. Target-to-background (T/B) ratios were obtained exclusively over the joint regions. Tc-99m HIG T/B ratios of the active joints in RA were significantly higher than those of the non-active joints and the control group (p < 0.05). Tc-99m HIG T/B ratios in active joints showed a progressive increase between 2 and 24 hour images (p < 0.05). In contrast, Tc-99m HSA TIE ratios decreased in all active joints significantly (p < 0.05) except the ankle joint region (p > 0.05). The T/B ratios in Tc-99m MDP bone scans were higher in all active joints than in non-active RA joints and joints of controls but significantly differences were only detected in wrist and elbow joints. All clinically active joints in VRA patients accumulated Tc-99m HIG and HSA, and showed increased Tc-99m MDP uptake. These joints had a very similar Tc-99m HIG retention pattern to the RA joints. The detection rate of active joint inflammation with Tc-99m HIG was much higher than that with Tc-99m MDP. The increasing Tc-99m HIG uptake ratio between 2 and 24 hours in contrast to Tc-99m HSA indicates the presence of other binding mechanisms besides increased vascularity in RA.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 50 条
  • [31] TC-99M MDP VS TC-99M DICARBOXYPROPANE DIPHOSPHONATE - A CLINICAL COMPARISON IN VARIOUS PATHOLOGICAL CONDITIONS
    GODART, G
    DUREZ, M
    BEVILACQUA, M
    ABRAMOVICI, J
    ROBIENCE, Y
    CLINICAL NUCLEAR MEDICINE, 1986, 11 (02) : 92 - 97
  • [32] THE UNIVERSAL MO-99 TC-99M GENERATOR - TC-99M ELUTION EFFICIENCY AND BREAKTHROUGH OF MO-99 IN THE TC-99M ELUATES
    VUGA, D
    MILENKOVIC, SM
    VUCINA, JL
    ISOTOPENPRAXIS, 1987, 23 (09): : 323 - 324
  • [33] STUDIES OF ARTHRITIS WITH TC-99M
    SKUPENOVA, A
    MAKAIOVA, I
    MAKAI, F
    HUPKA, S
    PIPA, V
    NUCLEAR MEDICINE-NUKLEARMEDIZIN, 1972, 11 (04): : 396 - 406
  • [34] PREPARATION AND EVALUATION OF TC-99M HYDROXYETHYL STARCH AS A POTENTIAL RADIOPHARMACEUTICAL FOR LYMPHOSCINTIGRAPHY - COMPARISON WITH TC-99M HUMAN SERUM-ALBUMIN, TC-99M DEXTRAN, AND TC-99M SULFUR MICROCOLLOID
    SADEK, S
    OWUNWANNE, A
    ABDELDAYEM, HM
    YACOUB, T
    LYMPHOLOGY, 1989, 22 (04) : 157 - 166
  • [35] Uptake of Tc-99m sestamibi and Tc-99m MDP in anaplastic carcinoma of the thyroid (nondiagnostic CT and ultrasound scans)
    Montes, TC
    Muñoz, C
    Rivero, JI
    Mota, JA
    Pustilnik, N
    Garcia, F
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (05) : 355 - 356
  • [36] 3-PHASE SCINTIGRAPHY OF TC-99M NANOCOLL VS TC-99M MDP IN ORTHOPEDICS
    VANDALEN, A
    STEMFOORT, AF
    DEJONGEBOK, JM
    DESCHRIJVER, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 244 - 244
  • [37] Tc-99m sestamibi and Tc-99m HMDP uptake in a malignant phyllodes tumor of the breast
    Ohta, H
    Yamamoto, S
    Ukikusa, M
    Awane, H
    Shintaku, M
    Irie, K
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (08) : 553 - 554
  • [38] RELATIVE LESION DETECTION ABILITY OF TC-99M HMDP AND TC-99M MDP - CONCISE COMMUNICATION
    VANDUZEE, BF
    SCHAEFER, JA
    BALL, JD
    CHILTON, HM
    COWAN, RJ
    KUNI, C
    TROW, R
    WATSON, NE
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (02) : 166 - 169
  • [39] BONE IMAGING WITH TC-99M MDP AND TC-99M HDP - A PRELIMINARY COMPARATIVE-STUDY
    RIJKE, AM
    CAMPS, JA
    PAUWELS, EKJ
    BLOM, J
    HERMANS, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1982, 7 (10): : A3 - A3
  • [40] CLINICAL COMPARISON OF TC-99M HMDP AND TC-99M-MDP - A MULTICENTER STUDY
    DELALOYE, B
    DELALOYEBISCHOF, A
    DUDCZAK, R
    KOPPENHAGEN, K
    MATA, F
    PENAFIEL, A
    MAUL, FD
    PASQUIER, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (05): : 182 - 185