Efficacy of Plasma ONE apparatus for disinfection of S. aureus, P. aeruginosa and E. coli bacteria from the solid surface

被引:4
|
作者
Zashev, Miroslav [1 ]
Donchev, Deyan [2 ]
Ivanov, Ivan [3 ]
Gornev, Radosvet [1 ]
机构
[1] Sofia Univ St Kliment Ohridski, Univ Hosp Lozenetz, Dept Gen Surg, Fac Med, Sofia, Bulgaria
[2] Sofia Univ St Kliment Ohridski, Univ Hosp Lozenetz, Dept Clin Microbiol & Virol, Fac Med, 1407 Kozyak str 1, Sofia, Bulgaria
[3] Natl Ctr Infect & Parasit Dis, Natl Reference Lab Control & Monitoring Antimicro, Dept Microbiol, Sofia, Bulgaria
关键词
Cold atmospheric plasma; Chronic wound; Wound pathogens; Bacterial decontamination; S; aureus; P; aeruginosa; ATMOSPHERIC-PRESSURE PLASMA; PSEUDOMONAS-AERUGINOSA; AIR PLASMA; INACTIVATION; BIOFILMS; JET;
D O I
10.1007/s40094-020-00401-5
中图分类号
O59 [应用物理学];
学科分类号
摘要
Cold atmospheric plasma (CAP) is a cocktail of charged particles with high antibacterial potency. In this study, we evaluated CAP efficacy generated by Plasma ONE, a mobile medical device against common chronic wound pathogens. Two sets of working saline suspensions, i.e. 10(5) and 10(3) CFU/ml of each reference strain E. coli, P. aeruginosa and S. aureus, were inoculated on Mueller-Hinton media plates and exposed to CAP for 30, 60, 120, 300 s and incubated for 24 h. The radiating nozzle surface was 3.4 cm. Plasma efficacy evaluation was based on the diameter of attained inactivation area and bacterial decontamination rate within. Plasma ONE device showed high capacity against S. aureus in all time intervals and exposure yielded a gradual time-dependent CFU reduction starting with 99.6% after 30 s in the 10(5) plates. Comparison between mean area diameters of S. aureus and E. coli of 30 and 120 s indicated a significant area increase (p < 0.05). In contrast, P. aeruginosa appeared more resistant to a longer exposure and the inactivation area was hardly extended following the longest exposure. In both Gram-negative bacteria, CFU reduction plateaued at 30 s in 10(3) petri dishes, while in 10(5) groups more than 120-s interval was insufficient for attaining full decontamination; however, treatment for 300 s led to complete eradication. Plasma ONE is effective against most commonly isolated pathogens from wounds, but its further validation requires data concerning efficacy in eradicating biofilms.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
  • [21] Comparative In-Vitro Functional Analysis of Synthetic Defensins and Their Corresponding Peptide Variants Against HIV-1NL4.3, E. coli, S. aureus and P. aeruginosa
    T. Mohan
    D. Mitra
    D. N. Rao
    International Journal of Peptide Research and Therapeutics, 2013, 19 : 245 - 255
  • [22] Comparison of the Effect of Microwave Radiation in the Disinfection Complete Dentures Contaminated with Two Types of Bacteria S. aureus and P. aeruginosa (in vitro) with Mechanical and Chemical Methods of CoregaTablets
    Khalili, Zahra
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 : 2017 - 2025
  • [23] From enemies to lovers: The trophic cooperation between S. aureus and P. aeruginosa around acetoin
    Blanc, Jules
    Cadot-Jet, Ninon
    Deshayes, Tom
    M S-MEDECINE SCIENCES, 2023, 39 (04): : 387 - 389
  • [24] The antimicrobial effect of Rred wine, White wine, Tannin and Alcohol E. coli, S. aureus, S. cholerae and E. faecalis What is the Chance of survival of Bacteria in wine?
    Mandl, Karin
    MITTEILUNGEN KLOSTERNEUBURG, 2012, 62 : 164 - 168
  • [25] Nano delivery systems to the rescue of ciprofloxacin against resistant bacteria E. coli; P. aeruginosa; Saureus; and MRSA and their infections
    Nwabuife, Joshua C.
    Omolo, Calvin A.
    Govender, Thirumala
    Journal of Controlled Release, 2022, 349 : 338 - 353
  • [26] Nano delivery systems to the rescue of ciprofloxacin against resistant bacteria ?E. coli; P. aeruginosa; Saureus; and MRSA? and their infections
    Nwabuife, Joshua C.
    Omolo, Calvin A.
    Govender, Thirumala
    JOURNAL OF CONTROLLED RELEASE, 2022, 349 : 338 - 353
  • [27] THE COMPORTMENT TO ANTIMICROBIALS OF SOME STRAINS OF E. COLI, S. AUREUS, E. FAECIUM AND E. FAECALIS ISOLATED FROM FOOD OF ANIMAL ORIGIN
    Moraru, Ramona
    Nastasa, V.
    Grecu, Mariana
    Burcoveanu, Ioana
    Savuta, G.
    Mares, M.
    REVISTA ROMANA DE MEDICINA VETERINARA, 2012, 22 (03): : 55 - 60
  • [28] Influence of surface characteristics of polypropylene on E. coli and S. aureus biofilms: From conventional to additive manufacturing of bioprocess equipment
    Lopez, Alvaro Morales
    Hasplova, Marketa
    Berglund, Johan
    Hjort, Karin
    Ahnfelt, Mattias
    Marteleur, Klas
    Finne-Wistrand, Anna
    APPLIED MATERIALS TODAY, 2024, 39
  • [29] In vitro analytical and antibiotic comparison of generic moxifl oxacin against E. coli and S. aureus bacteria strains
    Alviz-Amador, Antistio
    Mercado Camargo, Jairo E.
    Duran-Lengua, Marlene
    GABI JOURNAL-GENERICS AND BIOSIMILARS INITIATIVE JOURNAL, 2018, 7 (03): : 121 - 126
  • [30] Surface plasmon resonance detection of E. coli and methicillin-resistant S. aureus using bacteriophages
    Tawil, Nancy
    Sacher, Edward
    Mandeville, Rosemonde
    Meunier, Michel
    BIOSENSORS & BIOELECTRONICS, 2012, 37 (01): : 24 - 29