Development of a.CCD-based optical fluorescence imaging system

被引:23
|
作者
Li, YH [1 ]
Tang, D [1 ]
Chen, JY [1 ]
Wong, J [1 ]
Liu, H [1 ]
机构
[1] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
关键词
optical fluorescence; charge coupled devices; temporal resolution;
D O I
10.1117/12.533347
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An optical fluorescence imaging system was developed using a custom CCD camera. The system is designed and implemented to image an area of 20 nun by 20 mm with a spatial resolution of approximately 3.2 lp/mm. The temporal resolution is 490 frames per second. Comprehensive measurements were performed and the results have shown that the system is capable of providing high spatial resolution while maintaining good temporal resolutions and wide dynamic range. The system is a useful research tool in some biomedical experiments.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [21] Large area CCD based imaging system for mammography
    Tipnis, SV
    Nagarkar, VV
    Gaysinskiy, V
    O'Dougherty, P
    Klugerman, Y
    Miller, S
    Entine, G
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1043 - 1046
  • [22] Design of Area CCD Imaging System Based on FPGA
    Liu Qi
    Wang Peng
    He Zhikuan
    2017 2ND INTERNATIONAL CONFERENCE ON IMAGE, VISION AND COMPUTING (ICIVC 2017), 2017, : 597 - 600
  • [23] Development of a protocol for ccd calibration: Application to a multispectral imaging system
    Mansouri, A
    Marzani, FS
    Gouton, P
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2005, 20 (02): : 94 - 100
  • [24] BIST design for CCD based digital imaging system
    Jin, B.
    Park, N.
    Demidenko, Serge N.
    Choi, M.
    Lombardi, F.
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 2125 - +
  • [25] Optical system based on a CCD camera for ethanol detection
    Martinez-Hipatl, C.
    Munoz-Aguirre, S.
    Munoz-Guerrero, R.
    Castillo-Mixcoatl, J.
    Beltran-Perez, G.
    Gutierrez-Salgado, J. M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (10)
  • [26] Echo of the Optical Imaging System under Different Extent of Damage to CCD
    Zhang Ming-xin
    Nie Jin-song
    Dou Xian-an
    Sun Ke
    ACTA PHOTONICA SINICA, 2018, 47 (09)
  • [27] Research on testing technique of image inclining and graduation inclining of optical system based on CCD imaging theory
    Cao, WG
    Yang, RN
    An, ZY
    Li, XS
    Optical Design and Testing II, Pts 1 and 2, 2005, 5638 : 140 - 145
  • [28] Volumetric Diffuse Optical Tomography for Small Animals Using a CCD-Camera-Based Imaging System
    Lin, Zi-Jing
    Niu, Haijing
    Li, Lin
    Liu, Hanli
    INTERNATIONAL JOURNAL OF OPTICS, 2012, 2012
  • [29] Development of Diagnostic System for Atherosclerosis based on Intrinsic Fluorescence using Multispectral Imaging
    Ho, C.
    Horiuchi, T.
    Taniguchi, H.
    Umetsu, A.
    Hagisawa, K.
    Iwaya, K.
    Azmi, A.
    Zulaziz, N.
    Azhim, A.
    Shinomiya, N.
    Morimoto, Y.
    2015 10TH ASIAN CONTROL CONFERENCE (ASCC), 2015,
  • [30] Development of a combined optical and fluorescence Imaging system in frequency-domain for breast cancer detection
    Iftimia, N
    Liao, SP
    Jiang, HB
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 383 - 385