X-ray tests of a Pixel Array Detector for coherent x-ray imaging at the Linac Coherent Light Source

被引:32
|
作者
Koerner, L. J. [1 ]
Philipp, H. T. [1 ]
Hromalik, M. S. [1 ]
Tate, M. W. [1 ]
Gruner, S. M. [1 ,2 ]
机构
[1] Cornell Univ, Dept Phys, Atom & Solid State Phys Lab, Ithaca, NY 14853 USA
[2] Cornell Univ, CHESS, Ithaca, NY 14853 USA
来源
关键词
X-ray detectors; Pixelated detectors and associated VLSI electronics; X-ray diffraction detectors; INTERFACE STATES;
D O I
10.1088/1748-0221/4/03/P03001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Test results are presented of a pixel array detector (PAD) developed for x-ray imaging at the Stanford Linear Coherent Light Source (LCLS). The basic module of the PAD consists of two bump-bonded chips: a reverse-biased silicon diode chip of 185 x 194 pixels, each of which is coupled by bump-bonds to a charge integrating CMOS ASIC with digitization in each pixel. The LCLS experiment requires a high signal-to-noise ratio for detection of single 8 keV x-rays, a pixel full-well exceeding 1,000 8 keV x-rays, a frame-rate of 120 Hz, and the ability to handle the arrival of thousands of x-rays per pixel in tens of femtoseconds. Measurements have verified a pixel full-well value of 2,700 8 keV x-rays. Single 8 keV photon detection has been shown with a signal-to-noise ratio of > 6. Line-spread response measurements confirmed charge spreading to be limited to nearest neighbor pixels. Modules still functioned after dosages up to 75 Mrad(Si) at the detector face. Work is proceeding to incorporate an array of modules into a large-area detector.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [41] The Coherent X-ray Imaging Data Bank
    Maia, Filipe R. N. C.
    NATURE METHODS, 2012, 9 (09) : 854 - 855
  • [42] Phase imaging with partially coherent x-ray
    Han, SS
    Cheng, J
    Tang, HJ
    Xu, ZZ
    X-RAY LASERS 1998, 1999, 159 : 633 - 636
  • [43] Methods of Coherent X-Ray Diffraction Imaging
    Prosekov, P. A.
    Nosik, V. L.
    Blagov, A. E.
    CRYSTALLOGRAPHY REPORTS, 2021, 66 (06) : 867 - 882
  • [44] The Coherent X-ray Imaging Data Bank
    Filipe R N C Maia
    Nature Methods, 2012, 9 : 854 - 855
  • [45] X-RAY IMAGING A coherent look at stress
    Schreiber, Frank
    NATURE MATERIALS, 2011, 10 (11) : 813 - 814
  • [46] Detectors for X-ray Coherent Diffractive Imaging
    Hall, Christopher J.
    Lewis, Robert A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 130 - 132
  • [47] FEASIBILITY OF COHERENT X-RAY PRODUCTION BY X-RAY PUMPING
    CSONKA, PL
    CRASEMANN, B
    PHYSICAL REVIEW A, 1975, 12 (02): : 611 - 614
  • [48] Probing Organic Thin Films by Coherent X-ray Imaging and X-ray Scattering
    Patil, Nilesh
    Narayanan, Theyencheri
    Michels, Leander
    Skjonsfjell, Eirik Torbjorn Bakken
    Guizar-Sicairos, Manuel
    Van den Brande, Niko
    Claessens, Raf
    Van Mele, Bruno
    Breiby, Dag Werner
    ACS APPLIED POLYMER MATERIALS, 2019, 1 (07) : 1787 - 1797
  • [49] Coherent x-ray scattering
    van der Veen, F
    Pfeiffer, F
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2004, 16 (28) : 5003 - 5030
  • [50] Femtosecond Radiation Experiment Detector for X-Ray Free-Electron Laser (XFEL) Coherent X-Ray Imaging
    Philipp, Hugh T.
    Koerner, Lucas J.
    Hromalik, Marianne S.
    Tate, Mark W.
    Gruner, Sol M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (06) : 3795 - 3799