X-ray tests of a Pixel Array Detector for coherent x-ray imaging at the Linac Coherent Light Source

被引:32
|
作者
Koerner, L. J. [1 ]
Philipp, H. T. [1 ]
Hromalik, M. S. [1 ]
Tate, M. W. [1 ]
Gruner, S. M. [1 ,2 ]
机构
[1] Cornell Univ, Dept Phys, Atom & Solid State Phys Lab, Ithaca, NY 14853 USA
[2] Cornell Univ, CHESS, Ithaca, NY 14853 USA
来源
关键词
X-ray detectors; Pixelated detectors and associated VLSI electronics; X-ray diffraction detectors; INTERFACE STATES;
D O I
10.1088/1748-0221/4/03/P03001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Test results are presented of a pixel array detector (PAD) developed for x-ray imaging at the Stanford Linear Coherent Light Source (LCLS). The basic module of the PAD consists of two bump-bonded chips: a reverse-biased silicon diode chip of 185 x 194 pixels, each of which is coupled by bump-bonds to a charge integrating CMOS ASIC with digitization in each pixel. The LCLS experiment requires a high signal-to-noise ratio for detection of single 8 keV x-rays, a pixel full-well exceeding 1,000 8 keV x-rays, a frame-rate of 120 Hz, and the ability to handle the arrival of thousands of x-rays per pixel in tens of femtoseconds. Measurements have verified a pixel full-well value of 2,700 8 keV x-rays. Single 8 keV photon detection has been shown with a signal-to-noise ratio of > 6. Line-spread response measurements confirmed charge spreading to be limited to nearest neighbor pixels. Modules still functioned after dosages up to 75 Mrad(Si) at the detector face. Work is proceeding to incorporate an array of modules into a large-area detector.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The Coherent X-ray Imaging instrument at the Linac Coherent Light Source
    Liang, Mengning
    Williams, Garth J.
    Messerschmidt, Marc
    Seibert, M. Marvin
    Montanez, Paul A.
    Hayes, Matt
    Milathianaki, Despina
    Aquila, Andrew
    Hunter, Mark S.
    Koglin, Jason E.
    Schafer, Donald W.
    Guillet, Serge
    Busse, Armin
    Bergan, Robert
    Olson, William
    Fox, Kay
    Stewart, Nathaniel
    Curtis, Robin
    Miahnahri, Alireza Alan
    Boutet, Sebastien
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 514 - 519
  • [2] X-ray detectors at the Linac Coherent Light Source
    Blaj, Gabriel
    Caragiulo, Pietro
    Carini, Gabriella
    Carron, Sebastian
    Dragone, Angelo
    Freytag, Dietrich
    Haller, Gunther
    Hart, Philip
    Hasi, Jasmine
    Herbst, Ryan
    Herrmann, Sven
    Kenney, Chris
    Markovic, Bojan
    Nishimura, Kurtis
    Osier, Shawn
    Pines, Jack
    Reese, Benjamin
    Segal, Julie
    Tomada, Astrid
    Weaver, Matt
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 577 - 583
  • [3] The Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS)
    Boutet, Sebastien
    Williams, Garth J.
    [J]. NEW JOURNAL OF PHYSICS, 2010, 12
  • [4] Soft X-ray mirrors for the Linac coherent light source
    Pivovaroff, M. J.
    Bionta, R. M.
    Mccarville, T. J.
    Soufli, R.
    Stefan, P. M.
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS II, 2007, 6705
  • [5] Modelling of a hybrid pixel detector for coherent X-ray diffractive imaging
    Curwood, E. K.
    Hall, C.
    Lewis, R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 144 - 146
  • [6] The Soft X-ray Research instrument at the Linac Coherent Light Source
    Dakovski, Georgi L.
    Heimann, Philip
    Holmes, Michael
    Krupin, Oleg
    Minitti, Michael P.
    Mitra, Ankush
    Moeller, Stefan
    Rowen, Michael
    Schlotter, William F.
    Turner, Joshua J.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 498 - 502
  • [7] The X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source
    Robert, A.
    Curtis, R.
    Flath, D.
    Gray, A.
    Sikorski, M.
    Song, S.
    Srinivasan, V.
    Stefanescu, D.
    [J]. 11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [8] The X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source
    Alonso-Mori, Roberto
    Caronna, Chiara
    Chollet, Matthieu
    Curtis, Robin
    Damiani, Daniel S.
    Defever, Jim
    Feng, Yiping
    Flath, Daniel L.
    Glownia, James M.
    Lee, Sooheyong
    Lemke, Henrik T.
    Nelson, Silke
    Bong, Eric
    Sikorski, Marcin
    Song, Sanghoon
    Srinivasan, Venkat
    Stefanescu, Daniel
    Zhu, Diling
    Robert, Aymeric
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 508 - 513
  • [9] Predicting the coherent X-ray wavefront focal properties at the Linac Coherent Light Source (LCLS) X-ray free electron laser
    Barty, Anton
    Soufli, Regina
    McCarville, Tom
    Baker, Sherry L.
    Pivovaroff, Michael J.
    Stefan, Peter
    Bionta, Richard
    [J]. OPTICS EXPRESS, 2009, 17 (18): : 15508 - 15519
  • [10] Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source
    Reddy, Hemanth K. N.
    Yoon, Chun Hong
    Aquila, Andrew
    Awel, Salah
    Ayyer, Kartik
    Barty, Anton
    Berntsen, Peter
    Bielecki, Johan
    Bobkov, Sergey
    Bucher, Maximilian
    Carini, Gabriella A.
    Carron, Sebastian
    Chapman, Henry
    Daurer, Benedikt
    DeMirci, Hasan
    Ekeberg, Tomas
    Fromme, Petra
    Hajdu, Janos
    Hanke, Max Felix
    Hart, Philip
    Hogue, Brenda G.
    Hosseinizadeh, Ahmad
    Kim, Yoonhee
    Kirian, Richard A.
    Kurta, Ruslan P.
    Larsson, Daniel S. D.
    Loh, N. Duane
    Maia, Filipe R. N. C.
    Mancuso, Adrian P.
    Muhlig, Kerstin
    Munke, Anna
    Nam, Daewoong
    Nettelblad, Carl
    Ourmazd, Abbas
    Rose, Max
    Schwander, Peter
    Seibert, Marvin
    Sellberg, Jonas A.
    Song, Changyong
    Spence, John C. H.
    Svenda, Martin
    Van der Schot, Gijs
    Vartanyants, Ivan A.
    Williams, Garth J.
    Xavier, P. Lourdu
    [J]. SCIENTIFIC DATA, 2017, 4