Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound

被引:9
|
作者
Ali, Khushboo Qaim [1 ]
Soofi, Sajid Bashir [1 ]
Hussain, Ali Shabbir [1 ]
Ansari, Uzair [1 ]
Morris, Shaun [2 ]
Tessaro, Mark Oliver [3 ]
Ariff, Shabina [1 ]
Merali, Hasan [4 ]
机构
[1] Aga Khan Univ, Dept Pediat & Child Hlth, Karachi, Pakistan
[2] Hosp Sick Children, Div Infect Dis, Dept Pediat, Toronto, ON, Canada
[3] Hosp Sick Children, Emergency Point Of Care Ultrasound Program, Pediat Emergency Med, Toronto, ON, Canada
[4] McMaster Childrens Hosp, Pediat Emergency Med, Hamilton, ON, Canada
关键词
Simulation; Ultrasound training; Endotracheal tube; Point of care ultrasound; Resuscitation; Neonates; MEDICAL-EDUCATION; OF-CARE; PERFORMANCE; ULTRASONOGRAPHY; QUALITY; MODEL; CONFIRMATION; MANAGEMENT;
D O I
10.1186/s12909-020-02338-4
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Background: Simulators are an extensively utilized teaching tool in clinical settings. Simulation enables learners to practice and improve their skills in a safe and controlled environment before using these skills on patients. We evaluated the effect of a training session utilizing a novel intubation ultrasound simulator on the accuracy of provider detection of tracheal versus esophageal neonatal endotracheal tube (ETT) placement using point-of-care ultrasound (POCUS). We also investigated whether the time to POCUS image interpretation decreased with repeated simulator attempts. Methods: Sixty neonatal health care providers participated in a three-hour simulator-based training session in the neonatal intensive care unit (NICU) of Aga Khan University Hospital (AKUH), Karachi, Pakistan. Participants included neonatologists, neonatal fellows, pediatric residents and senior nursing staff. The training utilized a novel low-cost simulator made with gelatin, water and psyllium fiber. Training consisted of a didactic session, practice with the simulator, and practice with intubated NICU patients. At the end of training, participants underwent an objective structured assessment of technical skills (OSATS) and ten rounds of simulator-based testing of their ability to use POCUS to differentiate between simulated tracheal and esophageal intubations. Results: The majority of the participants in the training had an average of 7.0 years (SD 4.9) of clinical experience. After controlling for gender, profession, years of practice and POCUS knowledge, linear mixed model and mixed effects logistic regression demonstrated marginal improvement in POCUS interpretation over repeated simulator testing. The mean time-to-interpretation decreased from 24.7 (SD 20.3) seconds for test 1 to 10.1 (SD 4.5) seconds for Test 10, p < 0.001. There was an average reduction of 1.3 s (beta = - 1.3; 95% CI: - 1.66 to - 1.0) in time-to-interpretation with repeated simulator testing after adjusting for the covariates listed above. Conclusion: We found a three-hour simulator-based training session had a significant impact on technical skills and performance of neonatal health care providers in identification of ETT position using POCUS. Further research is needed to examine whether these skills are transferable to intubated newborns in various health settings.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Diagnostic accuracy of point-of-care ultrasound compared to standard-of-care methods for endotracheal tube placement in neonates
    Ariff, Shabina
    Ali, Khushboo Q.
    Tessaro, Mark O.
    Ansari, Uzair
    Morris, Shaun
    Soofi, Sajid Bashir
    Merali, Hasan S.
    PEDIATRIC PULMONOLOGY, 2022, 57 (07) : 1744 - 1750
  • [22] Implementation of point of care ultrasound to assess umbilical venous catheter position in the neonatal intensive care unit
    Polonio, Patrick Louis
    Tumin, Dmitry
    Zheng, Yingying
    Gandhi, Anita
    Bear, Kelly
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (25): : 7207 - 7209
  • [23] Implementation of a Bedside Point-of-Care Ultrasound Program in a Large Academic Neonatal Intensive Care Unit
    Pai, Vidya V.
    Noh, Caroline Y.
    Dasani, Reedhi
    Vallandingham, Shelby
    Manipon, Christine
    Haileselassie, Bereketeab
    Profit, Jochen
    Balasundaram, Malathi
    Davis, Alexis S.
    Bhombal, Shazia
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e76 - e84
  • [24] Point-of-Care Ultrasound in the Intensive Care Unit and Emergency Room
    Dodt, C.
    Buerke, M.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2018, 113 (08) : 614 - 615
  • [25] Point-of-care ultrasound: Infection control in the intensive care unit
    Lichtenstein, Daniel A.
    CRITICAL CARE MEDICINE, 2007, 35 (05) : S262 - S267
  • [26] Utility of point-of-care ultrasound in the pediatric intensive care unit
    Lyman, Reagan
    Yamaguchi, Yoshikazu
    Moharir, Alok
    Tobias, Joseph D.
    ANAESTHESIA PAIN & INTENSIVE CARE, 2019, 23 (03) : 314 - 317
  • [27] Impact Of Point Of Care Ultrasound In An Academic Medical Intensive Care Unit
    Anderson, A.
    Isakow, W.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [28] The Utility of Point-of-Care Ultrasound in the Pediatric Intensive Care Unit
    Watkins, Laura A.
    Dial, Sharon P.
    Koenig, Seth J.
    Kurepa, Dalibor N.
    Mayo, Paul H.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2022, 37 (08) : 1029 - 1036
  • [29] Defining the learning curve of point-of-care ultrasound for confirming endotracheal tube placement by emergency physicians
    Chenkin J.
    McCartney C.J.L.
    Jelic T.
    Romano M.
    Heslop C.
    Bandiera G.
    Critical Ultrasound Journal, 2015, 7 (1)
  • [30] Point-of-Care Ultrasound for the Tip of the Endotracheal Tube: A Neonatologist Perspective
    Sahin, Ozlem
    Tasar, Sevinc
    Colak, Derya
    Atay, Funda Yavanoglu
    Guran, Omer
    Akin, Ilke Mungan
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e2886 - e2892