Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities

被引:27
|
作者
Vinciguerra, Paolo [1 ]
Camesasca, Fabrizio I. [1 ,5 ]
Vinciguerra, Riccardo [1 ,2 ]
Arba-Mosquera, Samuel [3 ]
Torres, Ingrid [1 ]
Morenghi, Emanuela [1 ]
Randleman, J. Bradley [4 ]
机构
[1] Humanitas Clin & Res Ctr, Milan, Italy
[2] Univ Insubria, Div Ophthalmol, Dept Surg Sci, Varese, Italy
[3] SCHWIND Eye Tech Solut GmbH Co, Kleinostheim, Germany
[4] Univ Southern Calif, Keck Sch Med, Roski Eye Inst, Los Angeles, CA USA
[5] Humanitas Res Hosp, Via Manzoni 56, I-20089 Rozzano, Milan, Italy
关键词
LASER PHOTOREFRACTIVE KERATECTOMY; CONTRALATERAL EYE; INTERFACE IRREGULARITIES; FUNCTIONAL OUTCOMES; CORNEAL HAZE; MYOPIA; KERATOMILEUSIS; PRK; REGRESSION; LASIK;
D O I
10.3928/1081597X-20161122-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual outcomes and postoperative aberrations after surface ablation performed with a 750-Hz versus a 1,050-Hz excimer laser coupled with an ablation software designed to reduce corneal surface irregularity. METHODS: Retrospective comparative trial of myopic eyes that had refractive surgery consecutively treated with transepithelial advanced surface ablation with a 750-Hz excimer laser (750 group) versus a 1,050-Hz excimer laser coupled with the Smart Pulse Technology ablation software (SPT group). The SPT algorithm is a laser pulse technology software aimed at reducing surface irregularity of the stromal bed at the end of treatment. The authors evaluated the effect of this smoothing on final visual acuity. Patients were observed for 6 months. RESULTS: A total of 139 eyes in the 750 group and 40 eyes in the SPT group were evaluated. Epidemiological and preoperative refractive data of the two groups were comparable. Uncorrected distance visual acuity improved with time and was significantly better in the SPT group (-0.04 +/- 0.61 logMAR for the SPT group vs 0.02 +/- 0.78 logMAR for the 750 group) (P <.001). At 6 months, 55% versus 21% achieved 20/16 or better (P = .005) and 90% versus 65% achieved 20/ 20 or better (P = .019) visual acuity in the SPT and 750 groups, respectively. Corrected distance visual acuity improved with time and appeared to be influenced by group (P = .054), with better results in the SPT group. Coma and trefoil improved significantly with time in a similar manner in both groups. CONCLUSIONS: Surface ablation with the 1,050-Hz excimer laser and SPT software, aimed at reducing the final superficial stromal irregularity, led to improvement of 6-month uncorrected visual acuity.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [31] New approach to septal ablation: Glue (cyanoacrylate) septal ablation
    Oto, Ali
    Aytemir, Kudret
    Deniz, Ali
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (07) : 1021 - 1025
  • [32] Pulsed Field Ablation: a New Paradigm for Catheter Ablation of Arrhythmias
    Maan, Abhishek
    Koruth, Jacob
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (02) : 103 - 108
  • [33] A coupled thermal/fluid/chemical/ablation method on surface ablation of charring composites
    Li, Weijie
    Huang, Haiming
    Xu, Xiaoliang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 725 - 736
  • [34] Comparison of postoperative pain in patients following photorefractive keratectomy versus advanced surface ablation
    Blake, CR
    Cervantes-Castañeda, RA
    Macias-Rodríguez, Y
    Anzoulatous, G
    Anderson, R
    Chayet, AS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (07): : 1314 - 1319
  • [35] A new mechanism of surface ablation of charring materials for a vehicle during reentry
    Li, Weijie
    Huang, Haiming
    Xu, Xiaoliang
    Guo, Jin
    APPLIED THERMAL ENGINEERING, 2016, 106 : 838 - 849
  • [36] A NEW MODEL FOR EVALUATION OF SURFACE SMOOTHNESS FOLLOWING EXCIMER LASER ABLATION
    AQUAVELLA, JV
    LIANG, FQ
    GEASEY, SD
    DELCERRO, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 764 - 764
  • [37] Changes in Internal Aberrations Following Advanced Surface Ablation Treatment for the Correction of Astigmatism and Myopia
    Munger, R.
    Jackson, B. W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [38] A New Approach to Septal Ablation in Hypertrophic Cardiomyopathy; Onyx for Septal Ablation
    Aytemir, K.
    Oto, A.
    Arat, A.
    Yorgun, H.
    Dural, M.
    Kaya, B.
    Sahiner, L.
    Kabakci, G.
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (07): : S55 - S56
  • [39] Use of New Imaging CARTOR® Segmentation Module Software to Facilitate Ablation of Ventricular Arrhythmias
    Tovia-Brodie, Oholi
    Belhassen, Bernard
    Glick, Aharon
    Shmilovich, Haim
    Aviram, Galit
    Rosso, Raphael
    Michowitz, Yoav
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (02) : 240 - 248
  • [40] Efficacy of Diclofenac in Pain Reduction after Topography-Guided Transepithelial Surface Ablation
    Jost, Moritz
    Pfaeffli, Oliver
    Kaufmann, Claude
    Reichmuth, Valentina
    Thiel, Michael
    Baenninger, Philipp
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2022, 239 (04) : 386 - 389