Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities

被引:27
|
作者
Vinciguerra, Paolo [1 ]
Camesasca, Fabrizio I. [1 ,5 ]
Vinciguerra, Riccardo [1 ,2 ]
Arba-Mosquera, Samuel [3 ]
Torres, Ingrid [1 ]
Morenghi, Emanuela [1 ]
Randleman, J. Bradley [4 ]
机构
[1] Humanitas Clin & Res Ctr, Milan, Italy
[2] Univ Insubria, Div Ophthalmol, Dept Surg Sci, Varese, Italy
[3] SCHWIND Eye Tech Solut GmbH Co, Kleinostheim, Germany
[4] Univ Southern Calif, Keck Sch Med, Roski Eye Inst, Los Angeles, CA USA
[5] Humanitas Res Hosp, Via Manzoni 56, I-20089 Rozzano, Milan, Italy
关键词
LASER PHOTOREFRACTIVE KERATECTOMY; CONTRALATERAL EYE; INTERFACE IRREGULARITIES; FUNCTIONAL OUTCOMES; CORNEAL HAZE; MYOPIA; KERATOMILEUSIS; PRK; REGRESSION; LASIK;
D O I
10.3928/1081597X-20161122-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual outcomes and postoperative aberrations after surface ablation performed with a 750-Hz versus a 1,050-Hz excimer laser coupled with an ablation software designed to reduce corneal surface irregularity. METHODS: Retrospective comparative trial of myopic eyes that had refractive surgery consecutively treated with transepithelial advanced surface ablation with a 750-Hz excimer laser (750 group) versus a 1,050-Hz excimer laser coupled with the Smart Pulse Technology ablation software (SPT group). The SPT algorithm is a laser pulse technology software aimed at reducing surface irregularity of the stromal bed at the end of treatment. The authors evaluated the effect of this smoothing on final visual acuity. Patients were observed for 6 months. RESULTS: A total of 139 eyes in the 750 group and 40 eyes in the SPT group were evaluated. Epidemiological and preoperative refractive data of the two groups were comparable. Uncorrected distance visual acuity improved with time and was significantly better in the SPT group (-0.04 +/- 0.61 logMAR for the SPT group vs 0.02 +/- 0.78 logMAR for the 750 group) (P <.001). At 6 months, 55% versus 21% achieved 20/16 or better (P = .005) and 90% versus 65% achieved 20/ 20 or better (P = .019) visual acuity in the SPT and 750 groups, respectively. Corrected distance visual acuity improved with time and appeared to be influenced by group (P = .054), with better results in the SPT group. Coma and trefoil improved significantly with time in a similar manner in both groups. CONCLUSIONS: Surface ablation with the 1,050-Hz excimer laser and SPT software, aimed at reducing the final superficial stromal irregularity, led to improvement of 6-month uncorrected visual acuity.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [1] Current trends in advanced surface ablation
    Trattler, William B.
    Barnes, Scott D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) : 330 - 334
  • [3] Pain and discomfort in PRK versus advanced surface ablation
    Chayet, AS
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (05) : S752 - S752
  • [4] Update on Pain Management After Advanced Surface Ablation
    Mohammadpour, Mehrdad
    Heirani, Mohsen
    Khorrami-Nejad, Masoud
    Ambrosio Jr, Renato
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (11) : 782 - 790
  • [5] NEW LOOK AT SURGICAL ABLATION FOR ADVANCED CANCER OF BREAST
    DEGENSHEIN, GA
    SURGERY GYNECOLOGY & OBSTETRICS, 1976, 142 (04): : 578 - 579
  • [6] Advanced Surface Ablation in Mild (Fruste) Keratoconus: A Case Report
    Esporcatte, Louise P. G.
    Salomao, Marcella Q.
    Sena Jr, Nelson B.
    Lopes, Bernardo T.
    Ambrosio Jr, Renato
    OPHTHALMOLOGY AND THERAPY, 2020, 9 (02) : 355 - 363
  • [7] Advanced Surface Ablation in a Patient With Suspect Topography: A Case Report
    Morgado, Rodrigo Vilares
    Guedes, Jaime
    Ferreira, Ana Margarida
    Salomao, Marcella Q.
    Faria-Correia, Fernando
    Sousa, Amandio Rocha
    Ambrosio Jr, Renato
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [8] Advanced Surface Ablation in Mild (Fruste) Keratoconus: A Case Report
    Louise P. G. Esporcatte
    Marcella Q. Salomão
    Nelson B. Sena
    Bernardo T. Lopes
    Renato Ambrósio
    Ophthalmology and Therapy, 2020, 9 : 355 - 363
  • [9] Microwave ablation in locally advanced pancreatic carcinoma - A new look
    Lygidakis, N. J.
    Sharma, Sandesh-K
    Papastratis, P.
    Zivanovic, Vladimir
    Kefalourous, H.
    Koshariya, Mahim
    Lintzeris, I.
    Porfiris, T.
    Koutsiouroumba, D.
    HEPATO-GASTROENTEROLOGY, 2007, 54 (77) : 1305 - 1310
  • [10] Surface ablation techniques
    Taneri, Suphi
    Weisberg, Michael
    Azar, Dimitri T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02): : 392 - 408