A practical method to calibrate the slant angle of central X-ray for laminography scanning system

被引:12
|
作者
Yang, Min [1 ]
Zhu, Jianhua [1 ]
Liu, Qiu [1 ]
Duan, Shengling [1 ]
Liang, Lihong [2 ]
Li, Xingdong [3 ]
Liu, Wenli [3 ]
Meng, Fanyong [4 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
[2] China Special Equipment Inspect & Res Inst, Beijing 100013, Peoples R China
[3] Natl Inst Metrol, Beijing 100013, Peoples R China
[4] Chinese Acad Sci, Inst Proc Engn, State Key Lab Multiphase Complex Syst, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed laminography (CL); Geometrical calibration; Slant angle; Ellipse fitting; CONE-BEAM CT; RECONSTRUCTION; PARAMETERS;
D O I
10.1016/j.ndteint.2014.02.004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Computed laminography (CL) has a particular function in plate-type structure tomography. For CL reconstruction, slant angle of the central X-ray is an important parameter and must be calibrated accurately. A practical feasible calibration method to determine the slant angle is proposed. According to this method, a spherical phantom is fixed on the rotary table and turns a full 360 rotation. Then, image processing and the least-square fitting are performed to figure out the locus of the projection. Consequently, the slant angle is achieved in accordance with the property of the fitted ellipse. The experimental results prove that this method is easy to implement and meet the inspection requirements. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [1] Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system
    Yang, Min
    Zhang, Jianhai
    Yuan, Maodan
    Li, Xingdong
    Liu, Wenli
    Meng, Fanyong
    Song, Sung-Jin
    Wei, Dongbo
    NDT & E INTERNATIONAL, 2012, 52 : 16 - 22
  • [2] X-RAY LAMINOGRAPHY
    MOLER, RB
    INSTRUMENTS & CONTROL SYSTEMS, 1970, 43 (03): : 94 - &
  • [3] X-ray fluorescence micro-tomography and laminography using an x-ray scanning microscope
    Watanabe, N.
    Hoshinol, M.
    Yamamoto, K.
    Aoki, S.
    Takeuchi, A.
    Suzuki, Y.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [4] LamNI - an instrument for X-ray scanning microscopy in laminography geometry
    Holler, Mirko
    Odstrcil, Michal
    Guizar-Sicairos, Manuel
    Lebugle, Maxime
    Frommherz, Ulrich
    Lachat, Thierry
    Bunk, Oliver
    Raabe, Joerg
    Aeppli, Gabriel
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 730 - 736
  • [5] EVALUATION AND QUALIFICATION STANDARDS FOR AN X-RAY LAMINOGRAPHY SYSTEM
    SIEWERT, TA
    AUSTIN, MW
    LUCEY, GK
    PLOTT, MJ
    MATERIALS EVALUATION, 1992, 50 (09) : 1027 - &
  • [6] An improved method for inspection of solder joints using X-ray laminography and X-ray microtomography
    Kalukin, AR
    Sankaran, V
    Chartrand, B
    Millard, DL
    Kraft, RP
    Embrechts, MJ
    NINETEENTH IEEE/CPMT INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY SYMPOSIUM - PROCEEDINGS, 1996 IEMT SYMPOSIUM, 1996, : 438 - 445
  • [7] Development of x-ray laminography under an x-ray microscopic condition
    Hoshino, Masato
    Uesugi, Kentaro
    Takeuchi, Akihisa
    Suzuki, Yoshio
    Yagi, Naoto
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (07):
  • [8] X-ray laminography for SM applications
    Anon
    Evaluation Engineering, 1990, 29 (09):
  • [9] Spatial resolution of a laboratory based X-Ray cone-beam laminography scanning system for various trajectories
    Deyhle, Hans
    Towsyfyan, Hossein
    Biguri, Ander
    Mavrogordato, Mark
    Boardman, Richard
    Blumensath, Thomas
    NDT & E INTERNATIONAL, 2020, 111
  • [10] X-ray Phase Laminography with Talbot Interferometer
    Harasse, Sebastien
    Hirayama, Nozomi
    Yashiro, Wataru
    Momose, Atsushi
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804