Technique for pre-compliance testing of phasor measurement units

被引:12
|
作者
Brogan, Paul V. [1 ]
Laverty, David M. [1 ]
Zhao, Xiaodong [1 ]
Hastings, John [1 ]
Morrow, D. John [1 ]
Vanfretti, Luigi [2 ]
机构
[1] Queens Univ Belfast, Sch EEECS, Belfast, Antrim, North Ireland
[2] Rensselaer Polytech Inst, Troy, NY USA
基金
英国工程与自然科学研究理事会;
关键词
Phasor measurement unit; Synchrophasor; Compliance test; Dynamic performance;
D O I
10.1016/j.ijepes.2018.01.031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a technique for 'pre-compliance' testing of Phasor Measurement Units (PMUs) against the dynamic requirements of the IEEE C37.118.1-2014 standard, which include dynamic and steady-state test scenarios. The tests described are a necessary, but not complete, requirement for passing the IEEE standard and quickly highlight shortcomings in PMU operation during dynamic conditions. The pre-compliance test presented in this paper only requires typical relay test equipment, with little requirement for significant temporal accuracy when initiating waveform test files. The compliance test is intended to allow PMU owners to assess a device's performance before considering its use in monitoring dynamic performance. Failure of these tests can indicate the need to recalibrate or replace the PMU or find another vendor. The described method is applied to the voltage inputs of a typical commercial PMU and the results presented. The process for the creation of test waveforms is described, along with the data analysis technique used. The test waveforms and analysis source code are made available under open source licenses.
引用
收藏
页码:323 / 330
页数:8
相关论文
共 50 条
  • [31] An effective fault location technique for transmission grids using phasor measurement units
    Jiang, Zhen
    Miao, Shihong
    Xu, Hao
    Liu, Pei
    Zhang, Buhan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 653 - 660
  • [32] PHASOR MEASUREMENT UNITS: FUNCTIONALITY AND APPLICATIONS
    Tholomier, D.
    Kang, H.
    Cvorovic, B.
    2009 POWER SYSTEMS CONFERENCE, 2009, : 24 - 35
  • [33] Phasor Measurement Units and Phasor Data Concentrators Data Evaluation
    Manas, Jakub
    Bilik, Petr
    PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, : 460 - 463
  • [34] A Novel Technique to Detect False Data Injection Attacks on Phasor Measurement Units
    Almasabi, Saleh
    Alsuwian, Turki
    Javed, Ehtasham
    Irfan, Muhammad
    Jalalah, Mohammed
    Aljafari, Belqasem
    Harraz, Farid A.
    SENSORS, 2021, 21 (17)
  • [35] ISLANDING DETECTION WITH PHASOR MEASUREMENT UNITS
    Cardenas, Jorge
    Mikhael, George
    Kaminski, Jacek
    Voloh, Ilia
    2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 229 - 241
  • [36] The Pulse Coupled Phasor Measurement Units
    Ferrari, Lorenzo
    Gentz, Reinhard
    Scaglione, Anna
    Parvania, Masood
    2014 IEEE INTERNATIONAL CONFERENCE ON SMART GRID COMMUNICATIONS (SMARTGRIDCOMM), 2014, : 320 - 325
  • [37] On the accuracy specifications of Phasor Measurement Units
    Lixia, Marco
    Muscas, Carlo
    Sulis, Sara
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [38] End-to-End Remote Field Testing of Phasor Measurement Units Using Phasor Measurement Unit Performance Analyzer Test Suite
    Qin, Chuan
    Nie, Zhijie
    Banerjee, P.
    Srivastava, Anurag K.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (06) : 7067 - 7076
  • [39] Precision Measurement System for the Calibration of Phasor Measurement Units
    Georgakopoulos, Dimitrios
    Quigg, Stephen
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (06) : 1441 - 1445
  • [40] Low Cost Power Lead Extended Pre-Compliance Conducted EMI Measurement Setup and Diagnostics with Compact LISN
    Grobler, I.
    Gitau, M. N.
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1144 - 1149