All-Polyethylene versus Metal-Backed Tibial Components in Total Knee Arthroplasty

被引:6
|
作者
AbuMoussa, Samuel [1 ]
White, Charles Cody [2 ]
Eichinger, Josef K. [1 ]
Friedman, Richard J. [1 ]
机构
[1] Med Univ South Carolina, Dept Orthopaed & Phys Med, Charleston, SC 29425 USA
[2] Med Univ South Carolina, Coll Med, Charleston, SC 29425 USA
关键词
total Knee Arthroplasty; all-polyethylene tibia; metal-backed tibia; COMPARING EARLY FIXATION; CEMENTED COMPONENTS; RANDOMIZED RSA; FOLLOW-UP; HIP; REVISION; FAILURE; AP;
D O I
10.1055/s-0039-1683979
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
All-polyethylene tibial (APT) implants were incorporated into the initial design of the first total knee arthroplasty (TKA) systems. Since then, a dynamic shift has taken place and metal-backed tibial (MBT) implants have become the gold standard in TKA. This has mostly been due to the theoretical advantages of intraoperative flexibility and improved biomechanics in addition to the heavy influence of device manufacturers. MBT implant comes not only with a higher cost but also with potential for complications such as osteolysis, backside wear, and thinning of the polyethylene insert, which were not previously seen with APT implant. The majority of studies comparing APT and MBT implants have shown no difference in clinical outcomes and survivorship. Newer studies from the past decade have begun highlighting the economic advantages of APT implant, especially in patients undergoing primary, uncomplicated TKA. Use of APT implants in younger patients and those with a body mass index > 35 has not been extensively studied, but the existing literature suggests the use of APT implant in these cohorts to be equally as acceptable. With modern implant design and instrumentation, rising utilization of TKA along with current and future economic strain on health care, the increased use of APT implant could result in massive savings without sacrificing positive patient outcomes.
引用
收藏
页码:714 / 718
页数:5
相关论文
共 50 条
  • [31] Metal-backed versus all-polyethylene unicompartmental knee arthroplasty PROXIMAL TIBIAL STRAIN IN AN EXPERIMENTALLY VALIDATED FINITE ELEMENT MODEL
    Scott, C. E. H.
    Eaton, M. J.
    Nutton, R. W.
    Wade, F. A.
    Evans, S. L.
    Pankaj, P.
    BONE & JOINT RESEARCH, 2017, 6 (01): : 22 - 30
  • [32] All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register
    Gudnason, Asgeir
    Hailer, Nils P.
    W-Dahl, Annette
    Sundberg, Martin
    Robertsson, Otto
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12): : 994 - 999
  • [33] Revision of Unicompartmental to Total Knee Arthroplasty: Does the Unicompartmental Implant (Metal-Backed vs All-Polyethylene) Impact the Total Knee Arthroplasty?
    Scott, Chloe E. H.
    Powell-Bowns, Matilda F. R.
    MacDonald, Deborah J.
    Simpson, Philip M.
    Wade, Frazer A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : 2203 - 2209
  • [34] Changes in Bone Density in Metal-Backed and All-Polyethylene Medial Unicompartmental Knee Arthroplasty
    Scott, Chloe E. H.
    Wade, Frazer A.
    Bhattacharya, Rajarshi
    MacDonald, Deborah
    Pankaj, Pankaj
    Nutton, Richard W.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (03): : 702 - 709
  • [35] Anatomical total shoulder arthroplasty in young patients with osteoarthritis ALL-POLYETHYLENE VERSUS METAL-BACKED GLENOID
    Gauci, M. O.
    Bonnevialle, N.
    Moineau, G.
    Baba, M.
    Walch, G.
    Boileau, P.
    BONE & JOINT JOURNAL, 2018, 100B (04): : 485 - 492
  • [36] Use of cemented all-polyethylene and metal-backed acetabular components in total hip arthroplasty - A comparative study
    Markel, DC
    Huo, MH
    Katkin, PD
    Salvati, EA
    JOURNAL OF ARTHROPLASTY, 1995, 10 : S1 - S7
  • [37] All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties
    Yassin M.
    Garti A.
    Weissbrot M.
    Ashkenazi U.
    Khatib M.
    Robinson D.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (6) : 1087 - 1091
  • [38] All-polyethylene and Metal-backed Tibial Components Are Equivalent With BMI of Less Than 37.5
    Toman, Jared
    Iorio, Richard
    Healy, William L.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) : 108 - 116
  • [39] A Meta-Analysis Comparing All-Polyethylene Tibial Component to Metal-Backed Tibial Component in Total Knee Arthroplasty: Assessing Survivorship and Functional Outcomes
    Voss, Benjamin
    El-Othmani, Mouhanad M.
    Schnur, Anne-Kathrin
    Botchway, Albert
    Mihalko, William M.
    Saleh, Khaled J.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (11): : 2628 - 2636
  • [40] All-Polyethylene Tibial Components for Unicompartmental Knee Arthroplasty
    Plate, Johannes F.
    Augart, Marco A.
    Bracey, Daniel N.
    Jinnah, Alex
    Jinnah, Riyaz H.
    Poehling, Gary G.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2015, 25 (02) : 114 - 119