Sentinel lymph node mapping of the colon and stomach using lymphoseek in a pig model

被引:25
|
作者
Ellner, SJ
Méndez, J
Vera, DR
Hoh, CK
Ashburn, WL
Wallace, AM
机构
[1] Univ Calif San Diego, Dept Surg, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Ctr Comprehens Canc, La Jolla, CA 92093 USA
关键词
sentinel lymph node; colon cancer; gastric cancer; radiopharmaceutical; (99mT)c]DTPA-mannosyl-dextran; lymphoseek;
D O I
10.1245/ASO.2004.06.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Lymphoseek is a radiopharmaceutical designed for sentinel lymph node (SLN) mapping. The purpose of this study was to compare Lymphoseek colon and gastric pharmacokinetics with filtered [Tc-99m]sulfur colloid (fTcSC). Methods: Eight anesthetized pigs received an endoscopic injection of Lymphoseek or fTcSC in the stomach and colon. Scintigraphy was obtained of both administration sites at 15-minute intervals up to 3 hours after injection, after which all SLNs were identified by a handheld gamma probe through a laparotomy incision. Isosulfan blue was administered at the injection site 5 minutes before SLN mapping. The percentage of injected dose (%ID) was measured for all harvested nodes, and the clearance half-life (T-c) was calculated for all injection sites. Results: The mean Lymphoseek clearance for colon (T-c, 2.56 +/- 1.04 hours) and gastric (T-c, 3.83 +/- 1.18 hours) injection sites was statistically faster (P = .030) compared with fTcSC (colon Tc, 14.98 +/- 3.41 hours; stomach T-c, 14.52 +/- 4.08 hours). After 3 hours, Lymphoseek exhibited a mean SLN %ID of 1.32% +/- 1.71% in the colon and 2.04% +/- 2.12% in the stomach; this was not statistically different from fTcSC (colon, .63% +/- .39%; stomach, 2.35% +/- 2.90%). SLN uptake of Lymphoseek was significantly different from second-echelon node %ID for the colon (P = .011) and gastric (P = .029) injection sites. All SLNs exceeded 10 times background, and there was no discordance between isosulfan blue and Lymphoseek or fTcSC. Conclusions: Three hours after colon stomach administration, Lymphoseek demonstrated rapid injection site clearance, detectable SLN uptake, and low second-echelon node uptake.
引用
收藏
页码:674 / 681
页数:8
相关论文
共 50 条
  • [21] Lymph Node Ratio and Recurrence in Sentinel Lymph Node Mapping vs Conventional Surgery in Colon Cancer
    Soni, M.
    Saha, S.
    Sirop, S.
    Korant, A.
    Chakravarty, B.
    Singla, A.
    Pampanagouda, S.
    Iddings, D.
    Weise, D.
    ANNALS OF SURGICAL ONCOLOGY, 2010, 17 : S86 - S86
  • [22] The role of sentinel lymph node mapping in staging of colon and rectal cancer
    Esser, S
    Reilly, WT
    Riley, LB
    Eyvazzadeh, C
    Arcona, S
    DISEASES OF THE COLON & RECTUM, 2001, 44 (06) : 850 - 854
  • [23] Methods of sentinel lymph node mapping [Zur methodik des sentinel lymph node mapping]
    Kitagawa Y.
    Burian M.
    Kitajima M.
    Der Chirurg, 2004, 75 (8): : 751 - 755
  • [24] Noninvasive photoacoustic sentinel lymph node mapping using Au nanocages as a lymph node tracer in a rat model
    Song, Kwang Hyun
    Kim, Chulhong
    Cobley, Claire M.
    Xia, Younan
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2009, 2009, 7177
  • [25] A model for teaching sentinel lymph node mapping and excision and axillary lymph node dissection
    Dunnington, GL
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2003, 197 (01) : 119 - 121
  • [26] Sentinel lymph node mapping in colon cancer using radiocolloid as a single tracer: a feasibility study
    de Haas, Robbert J.
    Wicherts, Dennis A.
    Hobbelink, Monique G. G.
    van Diest, Paul J.
    Vleggaar, Frank P.
    Rinkes, Inne H. M. Borel
    van Hillegersberg, Richard
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (08) : 832 - 837
  • [27] The impact of the number of lymph node metastases on the overall recurrence of colon cancer in the era of sentinel lymph node mapping
    Arora, M. L.
    Saha, S.
    Sirop, S.
    Chakravarty, B.
    Korant, A.
    Soni, M.
    Wiese, D.
    Desai, D.
    Ganatra, B.
    Kaushal, S.
    Iddings, D.
    JOURNAL OF CLINICAL ONCOLOGY, 2009, 27 (15)
  • [28] Sentinel lymph node mapping for adenocarcinoma of the colon does not improve staging accuracy
    Caushaj, P. F.
    Salgado, J.
    Read, T. E.
    ISUCRS: PROCEEDINGS OF THE XXI BIENNIAL CONGRESS OF THE INTERNATIONAL SOCIETY OF UNIVERSITY COLON AND RECTAL SURGEONS, 2006, : 15 - +
  • [29] Sentinel Lymph Node Mapping for Adenocarcinoma of the Colon Does Not Improve Staging Accuracy
    Read, Thomas E.
    Fleshman, James W.
    Caushaj, Philip F.
    COLOPROCTOLOGY, 2005, 27 (03) : 145 - 152
  • [30] Sentinel lymph node mapping for adenocarcinoma of the colon does not improve staging accuracy
    Read, TE
    Fleshman, JW
    Caushaj, PF
    DISEASES OF THE COLON & RECTUM, 2004, 47 (04) : 579 - 580